6.2. Good read LED The Good Read LED can be disabled or set for several durations.

SET

_ZZ_

Disable indicator

T4

_T4_

Indicator duration: 0.2 s

T5

_T5_

Indicator duration: 0.4 s

T6

_T6_

Indicator duration: 0.8 s

T7

_T7_

END

_ZZ_

U126

Page 132

OPTICON UNIVERSAL MENU BOOK

7.1. Diagnostics

7. MISCELLANEOUS

The options in this part are primarily intended for diagnostic purposes. The following options are available: Transmit software version: The software version is transmitted. Transmit ROM checksum: The software calculated checksum over the internal program is transmitted. Transmit settings: The reader settings are transmitted as a string of hexadecimal numbers. Transmit ASCII printable string: The printable ASCII characters Hex 20 upto Hex 7F are transmitted. Transmit ASCII control string: The non printable ASCII control characters Hex 00 upto Hex 1F are transmitted.

_ZZ_

Transmit software version

Z1

_Z1_

Transmit ROM checksum

ZY

_ZY_

Transmit settings

Z3

_Z3_

Transmit ASCII printable string

ZA

_ZA_

Transmit ASCII control string

YV

_YV_

END

_ZZ_

U127

Miscellaneous

SET

7

Page 133

OPTICON UNIVERSAL MENU BOOK

7.2. Serial configuration support Disable configuring via RS232: The reader ignores all configuration commands from the RS232 port. The trigger and buzzer commands are still accepted. Enable configuring via RS232: The reader accepts all configuration commands from the RS232 port. Disable trigger via RS232: The reader ignores the trigger command, <Z> (Hex 5A), via the RS232 port. Enable trigger via RS232: The reader accepts the trigger command via the RS232 port. Disable buzzer via RS232: The reader ignores the buzzer command via the RS232 port. Enable buzzer via RS232: The reader accepts the buzzer command, <B> (Hex 42) for the good read buzzer and <E> (Hex 45) for the error buzzer, via the RS232 port. Disable Good read LED via RS232: The reader ignores the good read LED command via the RS232 port.

Error message - No label: Following this menu label a maximum of 4 direct input characters may be read. These characters will be transmitted if during the read time of the reader no label was detected. This function is only available on readers where the trigger is enabled. If no direct input character is read following the command, the error message is disabled. The function may be combined with 'Error message - No decode'. Error message - No decode: Following this menu label a maximum of 4 direct input characters may be read. These characters will be transmitted if during the read time of the reader a label was detected, but nothing could be decoded. This function is only available on readers where the trigger is enabled. If no direct input character is read following the command, the error message is disabled.The function may be combined with 'Error message - No label'. Example: The following two examples will set the messages 'NL<CR>' and 'ND<CR>' for No label and No decode respectively. The two examples may both be active at the same time. See figure 7.01.

Fig. 7.01. Serial configuration support

Enable Good read LED via RS232: The reader accepts the good read LED command, <L>(Hex 4C), via the RS232 port.

SET

SET

Disable ACK/NAK for RS232 commands: The reader does not transmit <ACK> nor <NAK> when a command is received.

Error - No label

Error - No decode

N

N

Enable ACK/NAK for RS232 commands: The reader transmits an <ACK> (Hex 06) after each valid RS232 command and a <NAK> (Hex 15) after each invalid RS232 command.

L

D

<CR>

<CR>

END

END

Enable/disable laser commands: The laser will not turn on when the trigger button is pressed or the trigger command is sent.

U128

Page 134

OPTICON UNIVERSAL MENU BOOK

7.2. Serial configuration support

_ZZ_

Disable configuring via RS232

TS

_TS_

Enable configuring via RS232

TT

_TT_

Disable trigger via RS232

8B

_8B_

Enable trigger via RS232

8C

_8C_

Disable buzzer via RS232

WB

_WB_

Enable buzzer via RS232

WA

_WA_

Disable good read LED via RS232

TY

_TY_

Enable good read LED via RS232

TZ

_TZ_

Disable ACK/NAK for RS232 comm.

WD

_WD_

Enable ACK/NAK for RS232 comm.

WC

_WC_

Enable enable/disable laser

SR

_SR_

Disable enable/disable laser

SQ

_SQ_

Clear error messages No label and No decode

TG

_TG_

END

_ZZ_ U129

7 Miscellaneous

SET

Page 135

OPTICON UNIVERSAL MENU BOOK

SET

_ZZ_

Error message No label

TH

_TH_

Error message No decode

TI

_TI_

END

_ZZ_

U130

Page 136

OPTICON UNIVERSAL MENU BOOK

A. TROUBLE SHOOTING The trouble shooting diagram can be of help if your reader does not operate as expected. If any problem is not covered or solved with this diagram you need to contact your dealer. Whether the reader operates or not can be checked in the following way: • it should beep after the power has been switched ON • it should either react on a trigger(if any) or it should emit light at the scan side of the reader (LEDs) See figure A.01.

Fig. A.01. Trouble shooting

Reader operates?

Check cabling

No

Yes No Problems reading menu?

Reads bar codes?

Yes

No

Setup reader or contact dealer

No

Setup bar code options

Yes

Appendix

Garbage on screen? Yes

Setup reader interface

Scans SET/END?

No

Reads any label?

Yes

No

Reader defect contact dealer

Yes

Software and menu do not match. Use matching menubook

Low buzzer indicates unsupported option

U131

Page 137

OPTICON UNIVERSAL MENU BOOK

B. GLOSSARY OF TERMS AIM: An acronym for Association for Automatic Identification and Mobility. This is referring to an organization that is an authority for standards for bar codes. ASCII: An acronym for American Standard Code for Information Interchange. This refers to a set of 128 characters that are standardized. These characters include all basic English characters, digits, punctuation characters and control characters. Bar: The dark element of a printed symbol. Bar code: An array of parallel rectangular bars and spaces which together represent data elements of characters in a particular symbology. The bars and spaces are arranged in a predetermined pattern, following unambiguous rules defined by the symbology. Bar code density: The number of bar code characters which can be represented in a linear unit of measure. Bar code density is often expressed in characters per inch. Bar code label: A label that carries a bar code and, optionally, other human-readable information; it can be affixed to an article. Bar code reader: A device used to scan and decode a bar code symbol. Bar width: The thickness of a bar measured from the edge closest to the symbol start character to the trailing edge of the same bar. Also known as element width.

Bluetooth: A wireless transmission protocol that uses radio frequency waves. More information on bluetooth can be found on the Internet site: http://www.bluetooth.org Bluetooth dongle: A device that converts electrical signals into radio frequency waves according to the bluetooth standard. CCD reader: A scanning device which uses the CCD technology. CCD is an acronym for Charge Coupled Device. Light from a lightsource within the CCD reader is reflected by a bar code label and falls on an array of light sensitive elements in the reader, the CCD. Whether the light is reflected depends on black or white parts of the bar code. The presence (or absence) of reflected light determines the presence (or absence) of electrical charge (electrons) in the distinct elements. The result is an electrical image of the bar code which can be used for further processing. Character: A single group of bars and spaces which represent an individual number, letter or punctuation mark. It is usually composed of six, seven or eight bits. Check digit: A character included within a symbol whose value is based, mathematically, on other characters within the symbol. It is used to perform a mathematical check to ensure the accuracy of the read. CMOS interface: A serial interface that typically is used between embedded devices. The CMOS standard defines a logical "1" level at the same level as the power supply of the electronic components that are used inside the device.

Baudrate: The rate at which data is transferred over a serial interface, expressed in bits per second. U132

Page 138

OPTICON UNIVERSAL MENU BOOK

Emulation:

CMOS scanner: A scanning device, which uses the CMOS technology. CMOS is an acronym for Complementary Metal Oxide Semiconductors. Light from a light source within the CMOS scanner is reflected by a bar code label and falls on an array of light sensitive elements in the scanner, the CMOS sensor. Whether the light is reflected depends on black or white parts of the bar code. The presence (or absence) of reflected light determines the presence (or absence) of electrical charge (electrons) in the distinct elements. The result is an electrical image of the bar code, which can be used for further processing.

The imitation of all or part of one device by another so that the mimicking device can accept the same data and perform the same functions as the actual device. Enable: To enable an option means, to activate it. Error correction: The possibility to correct read errors in a bar code. Most 2D bar codes have extra information that allows correction of the bar code. This makes it possible to read (partly) damaged bar codes.

Composite code: A bar code label that consists of two parts of two different symbologies: a linear (1D) part and a composite (2D) part. The composite part holds meta information about the product (like manufacturing date, quantity, etc.), while the linear part holds the product identification code. Data:

Default: A standard option or parameter setting. Default settings are present in the memory of a device. If no other value or option is chosen within a program (or bar code menu), the default settings are automatically chosen. Disable: To disable an option means, to deactivate. ECC: An acronym for Error Correction Code. See error correction. ECI: An acronym for Extended Channel Interpretation. This refers to a method used in 2-dimensional bar codes to encoded characters in other code sets then ASCII.

Relates to a symbol in which the data elements must be of specific length. Flow control: See handshaking. Format: A message or data structure that allows identification of control and data parts by their position within a frame. Handshaking:

Appendix

Digital information.

Fixed length:

The initial exchange between two data communication systems prior to and during data transmission. The first unit sends a signal, then waits for an appropriate signal in response. A handshake method (such as XON/ XOFF), parity setting, number of data bits, and number of stop bits. IEEE 802.15.4: A wireless transmission protocol that uses radio frequency waves. Intensity: The amount of radiant or luminous flux per unit solid angle that is diverging from a light source. Inter character delay: The time between transmitting two characters.

U133

Page 139

OPTICON UNIVERSAL MENU BOOK

Interface:

Prefix:

Allows devices to communicate with each other. Used most often to refer to the design of hardware and software which allows connection of network components and transfer of information.

One or more characters which accompany transported data. A prefix is put in front of the data and is part of the frame.

ISO: An acronym for International Organization for Standardization. This is referring to an organization, which is an authority for international standards.

Postamble: Also known as common suffix. This is one or more characters, which accompany the transported data. The postamble is transmitted at the end of the data, right after the code specific suffix. Protocol:

Keyboard wedge: This device permits you to connect a bar code reader between the computer and it's keyboard by way of an Y-cable. The computer "suggests" that the scanned data is keyboard entered. Normal software can still be used.

Usually, a specified method for determining how and when to format and send data. A serial (asynchronous) transmission protocol might include the baudrate, handshake method (XON/XOFF, etc.), parity setting, number of data bits (character length), and number of stop bits.

Laser reader: A scanning device which utilises a laser diode for it's source of illumination. Laser is an acronym for Light Amplification by Stimulated Emission of Radiation. A physical process which after focussing leads a light beam with special properties. A laser beam can be very powerful. For bar code scanning a low energy, safe laser beam is used. Opticon's laser readers are Class 1 (Highest security). Parity: A method of checking for errors in transmitted data. The eight bits of each transmitted character are added, and the total must always be an odd number for odd parity and an even number for even parity. If the total is wrong, the communications software detects that an error has occured during transmission and may request that the data is retransmitted. Preamble: Also known as common prefix. This is one or more characters, which accompany the transported data. The preable is put in front of the code specific prefix and the bar code data itself.

Resolution: In optics, sharpness; the ability of a reader to read the narrow bars in bar codes. Reader: A device that examines a spatial pattern, one part after another, and generates analog or digital signals corresponding to the pattern. The reader converts bar code symbols to electrical signals for input to a bar code reader decoder for processing and subsequent output through a data communications interface. Scan engine: The digitizer part of the bar code reader. The scan engine uses one of the following techniques: laser, CCD or CMOS. Scan rate: The scan engine consists of an illumination part (optional), a sensor part and a digitizer part. With this, it translates a printed bar code into a computer readable form. The scan engine uses one of the following techniques: laser, CCD or CMOS. Scanner: See Scan-engine. U134

Page 140

OPTICON UNIVERSAL MENU BOOK

Start bit: A control bit used to indicate the start of a group of data bits being sent in asynchronous transmission. Stop bit: A control bit used to indicate the end of a group of data bits being sent in asynchronous transmission. Structured append: The possibility to concatenate multiple bar codes into one block of data. This method is supported by most 2D bar codes. Suffix: One or more characters which accompany transported data. A suffix is put at the end of the data and is part of the frame. Symbology: A set of rules specifying the way in which data may be represented.

Appendix

Trigger: A signal that initiates an action or a series of events. The trigger button on a bar code reader will start the scan-engine and try to decode the scanned and digitized data. TTL interface: A serial interface that typically is used between embedded devices. The TTL standard defines a logical "1" level at 5 volt.

U135