The text of a manual · part 12 of 15
Opticon Universal Menu Book: bar code configuration and commands manual, pages 111 to 120
Pages 111 to 120 of 147
The original document is the PDF (593 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Opticon LG-K1WE5SP, Opticon 25-WEDGE-06 and Opticon HLT-1120 ELT-1120
Page 111
OPTICON UNIVERSAL MENU BOOK
SET
_ZZ_
^M (CR)
1M
_1M_
^N (SO)
1N
_1N_
^O (SI)
1O
_1O_
^P (DLE)
1P
_1P_
^Q (DC1)
1Q
_1Q_
^R (DC2)
1R
_1R_
^S (DC3)
1S
_1S_
^T (DC4)
1T
_1T_
^U (NAK)
1U
_1U_
^V (SYN)
1V
_1V_
^W (ETB)
1W
_1W_
^X (CAN)
1X
_1X_
^Y (EM)
1Y
_1Y_
END
_ZZ_ U106
Page 112
OPTICON UNIVERSAL MENU BOOK
_ZZ_
^Z (SUB)
1Z
_1Z_
^[ (ESC)
9A
_9A_
^\ (FS)
9B
_9B_
^] (GS)
9C
_9C_
^^ (RS)
9D
_9D_
^_ (US)
9E
_9E_
DEL (ASCII 127)
9F
_9F_
END
_ZZ_
U107
4 String options
SET
Page 113
OPTICON UNIVERSAL MENU BOOK
4.3.7. Direct input code id/length
SET
_ZZ_
Code identification
$2
_$2_
Code identification ISO15424 / AIM
$1
_$1_
Code length (1D = 2 digits, 2D = 6 digits)
$3
_$3_
Code length (1D and 2D = 6 digits)
$6
_$6_
END
_ZZ_
U108
Page 114
OPTICON UNIVERSAL MENU BOOK
5. READ OPTIONS This chapter allows to set the read mode, trigger type and redundancy.
5 Read options
U109
Page 115
OPTICON UNIVERSAL MENU BOOK
5.1. Read mode options The following read modes are available: Single read: When a bar code has been decoded, the reader will be turned OFF. The reader must be triggered again to read another label. This option and 'Disable trigger' can not be programmed at the same time. Multiple read: When a bar code has been decoded, the reader will stay ON for a time as set by 'Read time options' or indefinitely if the trigger switch has been disabled. The same label can only be decoded again after the label has not been detected for a number of scans. Continuous read: The reader will produce as much data as it can decode regardless whether it is the same or not. This mode is mainly used for demonstration and diagnosis.
time. The laser beam can now be moved to the required bar code. If the trigger switch is pressed again, the bar code is decoded and transmitted. If the read time expires, the laser switches off and the trigger sequence should be repeated. If the read time is set to 0, then if the trigger switch is pressed, the laser is on, but does not accept bar codes. As soon the trigger switch is released, the barcode is decoded and transmitted. Support for this option is reader dependent. Structured append time out: When a bar code consists of multiple physical bar codes, this time out value is used. The next bar code must be read before this time out is expired. The time out value is between 1 and 255 seconds. This value can be configured by reading 1 up to 3 direct input numeric characters from chapter: String options. Default the structured append time out is set to 30 seconds.
Disable trigger: This is applicable to readers which have a trigger switch. When this option is selected, the reader will stay ON all the time. Note: Selecting this option for a laser reader means that the laser diode is ON continuously, which may reduce the lifetime of this component. Also local legislation may require that the trigger switch is always enabled. Therefore it is recommended not to disable the trigger switch for laser readers. Add-on wait mode: Used if UPC/EAN with add-on is enabled. The reader searches within the selected time for a valid add-on code. If a valid add-on code is found, the reader transmits the data immediately. If nothing is found behind the code, the reader will transmit the data without add-on. If something is found behind the code, the reader ignored the code in case it is not a valid add-on. Trigger repeat: This option makes it more easy to select a single bar code from a sheet filled with bar codes. If the trigger switch is pressed once, the laser beam is on during the configured read U110
Page 116
OPTICON UNIVERSAL MENU BOOK
5.1. Read mode options
_ZZ_
Single read
S0
_S0_
Multiple read
S1
_S1_
Continuous read
S2
_S2_
Disable trigger
S7
_S7_
Enable trigger
S8
_S8_
Add-on wait mode disabled
XA
_XA_
Add-on wait mode 0.25 sec.
XB
_XB_
Add-on wait mode 0.50 sec.
XC
_XC_
Add-on wait mode 0.75 sec.
XD
_XD_
Disable trigger repeat
/K
_/K_
Enable trigger repeat
/M
_/M_
Structured append time out
BE2
_BE2_
END
_ZZ_
U111
5 Read options
SET
Page 117
OPTICON UNIVERSAL MENU BOOK
5.1.1. Multiple read reset time This option can be used in conjunction with multiple read mode. • for Laser and CCD readers, it sets the time that the reader should be pointed away from the label before it can decode the same label again • for Image readers, it sets the number of frames that the reader should be pointed away from the label before it can decode the same label again Indefinitely means that the next bar code must always be different, during the time the bar code reader is triggered. For the image reader the multiple reset time is not measured in ms, but in frames. The duration of each frame is variable, and is dependent of the captured image. See figure 5.01.
Fig. 5.01. Multiple read reset time
Multiple read reset time
50 ms 100 ms 200 ms 300 ms 400 ms 500 ms 600 ms Indefinitely
SET
_ZZ_
50ms
AH
_AH_
100ms
AI
_AI_
200ms
AJ
_AJ_
300ms
AK
_AK_
400ms
AL
_AL_
500ms
AM
_AM_
600ms
AN
_AN_
Indefinitely
AG
_AG_
END
_ZZ_ U112
1 2 3 4 Frames 5 6 7 Indefinitely
Page 118
OPTICON UNIVERSAL MENU BOOK
5.1.2. Quiet zone options With this option the reader can decode bar codes that have smaller start and/or end margins than specified for the symbology. Be careful when using this option. It may increase the possibility of partial reads and ghost reads. Do not use smaller margin checks then necessary. If possible replace the bar code labels by ones that have correct start and end margins.
_ZZ_
No margin check
YN
_YN_
Margin check 1/7 nominal
YO
_YO_
Margin check 2/7 nominal
YP
_YP_
Margin check 3/7 nominal
YQ
_YQ_
Margin check 4/7 nominal
YR
_YR_
Margin check 5/7 nominal
YS
_YS_
Margin check 6/7 nominal
YT
_YT_
Margin check normal
YU
_YU_
END
_ZZ_
U113
5 Read options
SET
Page 119
OPTICON UNIVERSAL MENU BOOK
5.1.3. Auto trigger options
5.2. Read time options
These options are used to activate the auto trigger option of the reader. This is only supported for reader equipped with the auto trigger option.
The length of the period that the reader is ON after the trigger switch is pressed, or (in multiple or continuous read mode) after a label has been read. Selecting a read time of 0 means that the reader will stay ON as long as the trigger switch is being pressed. Selecting a read time for readers without a trigger switch, or when the trigger switch is disabled, does not have any effect.
Disable auto trigger: The auto trigger function is not activated. Enable auto trigger: The reader will be triggered if it detects changes in brightness. Stand detection: The option enables auto trigger automatically in case the reader is inserted into the stand. If the reader is removed from the stand, auto trigger is disabled and the reader should be triggered manually. This option is disabled in case the auto trigger option is activated. Support for this option is reader dependent and a special stand is required.
SET
_ZZ_
Disable auto trigger
+F
_+F_
Enable auto trigger
+I
_+I_
Enable auto trigger stand detection
*4
_*4_
END
_ZZ_
U114
Page 120
OPTICON UNIVERSAL MENU BOOK
5.2. Read time options
_ZZ_
0 seconds
Y0
_Y0_
1 second
Y1
_Y1_
2 seconds
Y2
_Y2_
3 seconds
Y3
_Y3_
4 seconds
Y4
_Y4_
5 seconds
Y5
_Y5_
6 seconds
Y6
_Y6_
7 seconds
Y7
_Y7_
8 seconds
Y8
_Y8_
9 seconds
Y9
_Y9_
Read time * 10
YL
_YL_
Indefinitely
YM
_YM_
END
_ZZ_
U115
5 Read options
SET