Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 12 of 15

Opticon Universal Menu Book: bar code configuration and commands manual, pages 111 to 120

Pages 111 to 120 of 147

The original document is the PDF (593 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Opticon LG-K1WE5SP, Opticon 25-WEDGE-06 and Opticon HLT-1120 ELT-1120

Page 111

OPTICON UNIVERSAL MENU BOOK

SET

_ZZ_

^M (CR)

1M

_1M_

^N (SO)

1N

_1N_

^O (SI)

1O

_1O_

^P (DLE)

1P

_1P_

^Q (DC1)

1Q

_1Q_

^R (DC2)

1R

_1R_

^S (DC3)

1S

_1S_

^T (DC4)

1T

_1T_

^U (NAK)

1U

_1U_

^V (SYN)

1V

_1V_

^W (ETB)

1W

_1W_

^X (CAN)

1X

_1X_

^Y (EM)

1Y

_1Y_

END

_ZZ_ U106

Page 112

OPTICON UNIVERSAL MENU BOOK

_ZZ_

^Z (SUB)

1Z

_1Z_

^[ (ESC)

9A

_9A_

^\ (FS)

9B

_9B_

^] (GS)

9C

_9C_

^^ (RS)

9D

_9D_

^_ (US)

9E

_9E_

DEL (ASCII 127)

9F

_9F_

END

_ZZ_

U107

4 String options

SET

Page 113

OPTICON UNIVERSAL MENU BOOK

4.3.7. Direct input code id/length

SET

_ZZ_

Code identification

$2

_$2_

Code identification ISO15424 / AIM

$1

_$1_

Code length (1D = 2 digits, 2D = 6 digits)

$3

_$3_

Code length (1D and 2D = 6 digits)

$6

_$6_

END

_ZZ_

U108

Page 114

OPTICON UNIVERSAL MENU BOOK

5. READ OPTIONS This chapter allows to set the read mode, trigger type and redundancy.

5 Read options

U109

Page 115

OPTICON UNIVERSAL MENU BOOK

5.1. Read mode options The following read modes are available: Single read: When a bar code has been decoded, the reader will be turned OFF. The reader must be triggered again to read another label. This option and 'Disable trigger' can not be programmed at the same time. Multiple read: When a bar code has been decoded, the reader will stay ON for a time as set by 'Read time options' or indefinitely if the trigger switch has been disabled. The same label can only be decoded again after the label has not been detected for a number of scans. Continuous read: The reader will produce as much data as it can decode regardless whether it is the same or not. This mode is mainly used for demonstration and diagnosis.

time. The laser beam can now be moved to the required bar code. If the trigger switch is pressed again, the bar code is decoded and transmitted. If the read time expires, the laser switches off and the trigger sequence should be repeated. If the read time is set to 0, then if the trigger switch is pressed, the laser is on, but does not accept bar codes. As soon the trigger switch is released, the barcode is decoded and transmitted. Support for this option is reader dependent. Structured append time out: When a bar code consists of multiple physical bar codes, this time out value is used. The next bar code must be read before this time out is expired. The time out value is between 1 and 255 seconds. This value can be configured by reading 1 up to 3 direct input numeric characters from chapter: String options. Default the structured append time out is set to 30 seconds.

Disable trigger: This is applicable to readers which have a trigger switch. When this option is selected, the reader will stay ON all the time. Note: Selecting this option for a laser reader means that the laser diode is ON continuously, which may reduce the lifetime of this component. Also local legislation may require that the trigger switch is always enabled. Therefore it is recommended not to disable the trigger switch for laser readers. Add-on wait mode: Used if UPC/EAN with add-on is enabled. The reader searches within the selected time for a valid add-on code. If a valid add-on code is found, the reader transmits the data immediately. If nothing is found behind the code, the reader will transmit the data without add-on. If something is found behind the code, the reader ignored the code in case it is not a valid add-on. Trigger repeat: This option makes it more easy to select a single bar code from a sheet filled with bar codes. If the trigger switch is pressed once, the laser beam is on during the configured read U110

Page 116

OPTICON UNIVERSAL MENU BOOK

5.1. Read mode options

_ZZ_

Single read

S0

_S0_

Multiple read

S1

_S1_

Continuous read

S2

_S2_

Disable trigger

S7

_S7_

Enable trigger

S8

_S8_

Add-on wait mode disabled

XA

_XA_

Add-on wait mode 0.25 sec.

XB

_XB_

Add-on wait mode 0.50 sec.

XC

_XC_

Add-on wait mode 0.75 sec.

XD

_XD_

Disable trigger repeat

/K

_/K_

Enable trigger repeat

/M

_/M_

Structured append time out

BE2

_BE2_

END

_ZZ_

U111

5 Read options

SET

Page 117

OPTICON UNIVERSAL MENU BOOK

5.1.1. Multiple read reset time This option can be used in conjunction with multiple read mode. • for Laser and CCD readers, it sets the time that the reader should be pointed away from the label before it can decode the same label again • for Image readers, it sets the number of frames that the reader should be pointed away from the label before it can decode the same label again Indefinitely means that the next bar code must always be different, during the time the bar code reader is triggered. For the image reader the multiple reset time is not measured in ms, but in frames. The duration of each frame is variable, and is dependent of the captured image. See figure 5.01.

Fig. 5.01. Multiple read reset time

Multiple read reset time

50 ms 100 ms 200 ms 300 ms 400 ms 500 ms 600 ms Indefinitely

SET

_ZZ_

50ms

AH

_AH_

100ms

AI

_AI_

200ms

AJ

_AJ_

300ms

AK

_AK_

400ms

AL

_AL_

500ms

AM

_AM_

600ms

AN

_AN_

Indefinitely

AG

_AG_

END

_ZZ_ U112

1 2 3 4 Frames 5 6 7 Indefinitely

Page 118

OPTICON UNIVERSAL MENU BOOK

5.1.2. Quiet zone options With this option the reader can decode bar codes that have smaller start and/or end margins than specified for the symbology. Be careful when using this option. It may increase the possibility of partial reads and ghost reads. Do not use smaller margin checks then necessary. If possible replace the bar code labels by ones that have correct start and end margins.

_ZZ_

No margin check

YN

_YN_

Margin check 1/7 nominal

YO

_YO_

Margin check 2/7 nominal

YP

_YP_

Margin check 3/7 nominal

YQ

_YQ_

Margin check 4/7 nominal

YR

_YR_

Margin check 5/7 nominal

YS

_YS_

Margin check 6/7 nominal

YT

_YT_

Margin check normal

YU

_YU_

END

_ZZ_

U113

5 Read options

SET

Page 119

OPTICON UNIVERSAL MENU BOOK

5.1.3. Auto trigger options

5.2. Read time options

These options are used to activate the auto trigger option of the reader. This is only supported for reader equipped with the auto trigger option.

The length of the period that the reader is ON after the trigger switch is pressed, or (in multiple or continuous read mode) after a label has been read. Selecting a read time of 0 means that the reader will stay ON as long as the trigger switch is being pressed. Selecting a read time for readers without a trigger switch, or when the trigger switch is disabled, does not have any effect.

Disable auto trigger: The auto trigger function is not activated. Enable auto trigger: The reader will be triggered if it detects changes in brightness. Stand detection: The option enables auto trigger automatically in case the reader is inserted into the stand. If the reader is removed from the stand, auto trigger is disabled and the reader should be triggered manually. This option is disabled in case the auto trigger option is activated. Support for this option is reader dependent and a special stand is required.

SET

_ZZ_

Disable auto trigger

+F

_+F_

Enable auto trigger

+I

_+I_

Enable auto trigger stand detection

*4

_*4_

END

_ZZ_

U114

Page 120

OPTICON UNIVERSAL MENU BOOK

5.2. Read time options

_ZZ_

0 seconds

Y0

_Y0_

1 second

Y1

_Y1_

2 seconds

Y2

_Y2_

3 seconds

Y3

_Y3_

4 seconds

Y4

_Y4_

5 seconds

Y5

_Y5_

6 seconds

Y6

_Y6_

7 seconds

Y7

_Y7_

8 seconds

Y8

_Y8_

9 seconds

Y9

_Y9_

Read time * 10

YL

_YL_

Indefinitely

YM

_YM_

END

_ZZ_

U115

5 Read options

SET