The text of a manual · part 5 of 11
Handheld Data Terminal H15 User Manual, pages 41 to 50
Pages 41 to 50 of 101
The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Opticon H-15
Page 41
Opticon H15 User Manual d)
Diags Tab
Figure 2-16. Diags tab
•
(Re)connect: Disable and enable the radio, apply or reapply the current profile, and attempt to associate and authenticate to the wireless LAN, logging all activity in the output area at the bottom.
•
Release/Renew: Obtain a new IP address through DHCP release/renew, and log all activity in the output area at the bottom.
•
Start Ping: Start a continuous ping to the address in the edit box next to it. Make sure the terminal is (rec)connected. Once the button is clicked, its name and function will change to Stop Ping. Moving to an SCU window other than Status or Diags also will stop the ping. Pings will continue until you tap the Stop Ping button, move to an SCU window other than Diags or Status, exit SCU, or remove the radio.
•
Diagnostics: Attempt to (re)connect to an AP, and provide a more thorough dump of data than is obtained with (Re)connect. The dump will include radio state, profile settings, global settings, and a BSSID list of APs in the area.
•
Save To...: Save the diagnostics output to a file.
2-34
Page 42
Opticon H15 User Manual e)
Global Tab
Figure 2-17. Global tab
Global settings include: •
Radio and security settings that apply to all profiles
•
Settings that apply to SCU itself
An administrator can define and change most global settings on the Global Settings Tab in SCU. The default setting for each global setting ensures reliable operation in most environments. Consult the user’s guide for details on all global settings. 2.4.6. Reading Barcodes To use the scanning function, complete the following steps: 1. If you have not already done so, remove the protective plastic film before using devices equipped with a 1D laser barcode reader. 2. Run the WordPad software program. 3. Press one of the three barcode reader trigger buttons. 4. Aim the scanning beam at the center of the barcode.
Figure 2-18. Aiming the scanning beam
2-35
Page 43
Opticon H15 User Manual
•
Good scanning position. The reading range is from 50 to 650mm distance. Decrease the scanning distance to the barcode when scanning small barcodes. Increase the scanning distance from the barcode when scanning large barcodes. The scanning area is visible by a red laser beam.
Figure 2-19. Good scanning position
•
Bad scanning position. Make sure that the laser beam sweeps across whole barcode. Scanning operations may fail if the laser beam is positioned as below.
Figure 2-20. Bad scanning position
•
Upon reading a barcode, the red LED indicator turns on until the trigger is released, or after five seconds. The green LED and the beep tone indicates a good read.
NOTE: This product scans using laser light. Never look directly into the laser light or shine the laser light into the eyes. 2.4.7. Help Tapping the question mark (?) will retrieve help information for each program.
2.5. Power management 2.5.1. Suspend Mode The PDT will go into a suspended mode when it is idle for a period of time. The idle duration can be customized using the Power control panel. Suspend mode works and looks just like you have turned the unit off. Press the to suspend the PDT; press the Power key again for the PDT to Power key resume its previous state. Use the Battery power control panel to set the duration to switch state to Suspend mode when system using battery power. This will save battery power when PDT is not in use.
2-36
Page 44
Opticon H15 User Manual
The following conditions will suspend: •
Press the <Power> key while the unit is on.
•
The duration timer of item Switch state to Suspend expires, which indicates that there has been no use for a specified of time.
•
The battery pack is completely discharged.
Figure 2-21. Schemes tab
2.5.2. Resuming Use the following method to resume (wake up the Terminal): •
Press the <Power> key to suspend or resume (wake up).
•
Dock the terminal into the cradle.
When a battery pack completely discharges while the unit is in suspend mode, the Terminal remains suspended until discharged battery condition is corrected.
2-37
Page 45
Opticon H15 User Manual
2.6. Resetting the Terminal 2.6.1. Soft (Warm) Reset A warm reset is a transition from the on, idle, or suspend power state that close all applications, clears the working RAM, but preserves the file system. Reason to Warm Reset: If an application “hangs”, initiate a warm reset to terminate the application only. Process to Warm Reset: To warm reset, press “F1” and “F4” button simultaneously. After Warm Reset: •
The desktop appears with the application shortcuts on the screen.
•
The custom settings in the registry are persistent.
2.6.2. Hard (Cold) Reset CAUTION: It is best to use only the warm reset. Try a warm reset before you initiate a cold reset. All applications will be closed and working RAM and all files will be cleared if you initiate a cold reset. Before a cold reset, back up your files to Flash ROM, Flash Card, or PC. 1. You can use Cold Reset to initialize the Terminal if WinCE OS lock up or Warm Reset has no effect. 2. To perform Cold Reset, press “Power”, “F1” and “F4” button simultaneously. 3. Terminal will initiate boot up after Cold Reset.
2-38
Page 46
Opticon H15 User Manual
3. Settings 3.1. Introduction To view available options for the terminal settings, tap Start > Settings. There are three items inside Settings: Control Panel, Network and Dial-up, and Taskbar and Start.
3.2. Control Panel View the Control Panel and the settings you can modify by tapping Start > Settings > Control Panel.
3-1
Page 47
Opticon H15 User Manual
3.2.1. Bluetooth Device Properties
ICON
ITEM & FUNCTION “BT Service” Tab: • • •
•
•
•
Select Enable Bluetooth Device to enable the Bluetooth device (Figure 3-1). Wait for 20 seconds to initialize the Bluetooth hardware correctly. Tap Scan Device Service to open the Bluetooth Manager window. Then tap the Scan Device button to initiate a scan for Bluetooth hardware. The Bluetooth manager lists the Bluetooth devices that it finds (Figure 3-2). If Bluetooth hardware is not found, the Bluetooth Hardware Error window appears (Figure 3-3). If Bluetooth hardware is not authenticated, the Bluetooth authentication error window appears (Figure 3-4). Double tap the device to connect to on the device list. The Bluetooth Manager Authentication window appears. Tap No to connect to the device without authentication, or tap Yes to authenticate the device before connecting (Figure 3-5). If the Yes button was selected in the Bluetooth Manager Authentication window, the enter PIN windows appears. Enter a PIN (between 1 and 16 alpha numeric characters) in the Enter PIN text box, and tap OK. The mobile computer sends the PIN request to the device for bonding. When prompted, the same PIN must be entered on the other device. When the PIN is entered correctly on the other device, the bonded icon appears on the device list (Figure 3-6).
“Serial Port” Tab: • • •
•
Tap Enable Bluetooth Device to enable the Bluetooth device. (Figure 3-7) Wait for 20 seconds to initialize the Bluetooth hardware correctly. If want to use Virtual com, only SPP base profiles are supported.(i.e., Printer, Modem, and LAP). Switch to the Serial Port tab, and you will see the devices that are trusted or active. Select the device to which you want to map a virtual COM port and select the virtual COM port you want to use. (Figure 3-8 to 3-10) Now the selected COM port is mapped for the BT device (Figure 3-11).
Bluetooth Indicators: •
For a description of the Bluetooth icons, refer to figure 3-12 Bluetooth icons.
3-2
Page 48
Opticon H15 User Manual
Figure 3-1. BT Service – Enable Bluetooth Device
Figure 3-2. BT Service – Bluetooth Manager scan Inquiry
Figure 3-3. BT Service – Bluetooth hardware error
Figure 3-4. BT Service – Bluetooth authentication error
3-3
Page 49
Opticon H15 User Manual
Figure 3-5. BT Service – Bluetooth PIN Window
Figure 3-6. BT Service – Bluetooth Scan Device Trusted/Active
Figure 3-7. Serial Port – Enable Bluetooth Device
Figure 3-8. Serial Port – Bluetooth Manager Window
3-4
Page 50
Opticon H15 User Manual
Figure 3-9. Serial Port – Bluetooth Manager Window
Figure 3-10. Serial Port – Bluetooth Manager Window
Figure 3-11. Serial Port – Bluetooth Manager Window
NOTE: If the device to which the Terminal is bonding does not appear in the list, ensure it is turned on, in discoverable mode, and within range (30 feets / 10 meters) of the Terminal.
3-5