The text of a manual · part 5 of 12
V520-LHA7127 Miniature High Speed CCD Fixed Position Scanner User Manual: Section 3- Positioning the Scanner
Pages 18 to 23 of 77, from V520-LHA7127 Miniature High Speed CCD Fixed Position Scanner User Manual
The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Omron V520
Page 18
Section 3 - Positioning the Scanner
V520-LHA7127
Section 3 Positioning the Scanner Achieving Optimum Performance Three items greatly impact performance: • Distance (from the scan window) to the bar code • Spectral reflection • Quality of Bar Code labels 1) Distance to the Bar Code The operation of the scanner is similar to a camera. If you photograph an object that is out of focus, the resulting picture will be blurry. The same is true with the scanner. If the bar code label is out of focus, the scanner may have difficulty decoding what appears to be fuzzy bars and spaces. Focal Distance
Ideally, the distance from the window of the scanner to the bar code label should be equal to the focal distance of the scanner. For the V520-LHA7127 series fixed position scanners, the nominal focal distance is: Front view
1.4 in. (35 mm)
9
Page 19
Section 3 - Positioning the Scanner
V520-LHA7127
Depth-of-Field
Just as with a camera, the scanner has a depth-of-field. It can read bar codes that are not precisely at the focal distance - maybe a little closer, or a little farther away. However, if the bar code label is positioned too far from the focal distance, the scanner may not be able to successfully decode it. The depth-of-field varies based on the density of the bar code, i.e., the thickness of the bars. Very high density bar codes (which have very narrow bars) are readable over a much shorter distance range than low density bar codes with larger bars. The following table shows the “typical” depth-of-field (closest to farthest reading distances) for the V520-LHA7127 series scanners. The actual performance may differ slightly from unit to unit. Also, it is important to note that this data was measured under ideal conditions using high quality bar code labels. In a “real world” environment the conditions will not be as ideal. Therefore, the best practice is to position the scanner at its focal distance rather than at the extremes of its depth-of-field. Typical Reading Distance from Window (Depth of Field) Density of Bar Code 15 mil 10 mil 6 mil 4 mil
Near Distance
Far Distance
0.6 in. 0.8 in. 1.1 in. 1.3 in.
2.3 in. 2.2 in. 1.8 in. 1.65 in.
Readable Bar Code Width (Field-of-View) Distance from Window 0.5 in. 1.0 in. 1.5 in. 2.0 in. 2.5 in.
Max. Width 2.0 in. 2.7 in. 3.4 in. 3.9 in. 4.5 in.
The table above shows the field-of-view at various distances from the window. The field-of-view is the maximum width that the scanner is capable of reading. A bar code label postioned anywhere within this fieldof-view can be decoded. The field-of-view is also a measure of the widest bar code label that can be read. Remember: the width of a bar code label includes not only the bars and spaces but also the required white space (quiet zone) on each end. Good design policy is to position the scanner at its focal distance and at the center of the field-of-view. Do not position it near the extremes of the reading range.
10
Page 20
Section 3 - Positioning the Scanner
V520-LHA7127
2) Avoiding Specular Reflection Do not position the scanner at an angle that causes the LED illumination to be reflected directly back into the scanner. This is called specular reflection. Too much reflected light can “blind” the scanner preventing a good decode. If the bar code label is located on a flat surface, specular reflectivity occurs between 0 to 10 degrees off perpendicular (See diagram). If the bar code label is located on a cylindrical surface, such as a test tube, the angle of specular reflection is measured tangent to the curve. If the curved surface is also moving, there may be more than one position causing specular reflection. The following diagram indicates the area to avoid: Front View Hatched no read specular zone ±10˚
Height of barcode
3) Quality Bar Code Labels The quality of the bar code label can affect the scanning performance. Poor quality labels are more difficult to decode and may result in non-reads or potential misreads. The bar code label should be printed to specifications. This means that the bars are printed within spec, with the correct widths, no ink spread, crisp edges and no voids. There should be a sufficient quiet zone on both ends of the bar code label. For best results, the paper or label stock should have a matte finish to diffuse light. The print contrast signal (which is a comparison of the reflectance of the bars and the background stock) should be as high as practical.
Measuring Scanner Performance Two methods are helpful in determining the optimum position of the scanner. The first method is to program the scanner for Trigger Disable and Continuous Read modes. The scanner will always be on and will continuously read the same bar code. Since the buzzer sounds each time the bar code is read, the sound of the buzzer can be used like a “Geiger counter.” As the position of the scanner changes the sound of the buzzer will change. The buzzer sound will be loudest and most continuous at the best reading positions.
11
Page 21
Section 3 - Positioning the Scanner
V520-LHA7127
The Read Rate Test The second method, the Read Rate Test, provides a mathematical calculation of scanning performance. In this test the scanner scans a bar code 700 times and then calculates the number of those scans that resulted in a good decode. That number, expressed as a percentage, will be transmitted to the host. For example, 93% means that the scanner decoded the bar code symbol 93 times out of the 700 scan attempts. By performing the Read Rate Test with the scanner mounted in various positions you can determine which of those locations results in the best performance. How to Perform the Read Rate Test Perform the following steps after you have correctly configured communications to the computer via your RS-232C port and power is made available to the scanner: Send the command: <Escape> U8 <Carriage Return> Note Be sure to use capital letters, e.g. “U8,” not “u8.” The scanner will read the barcode continuously and will display the ratio of the number of successful reads to the total number of attempts. The printout on the screen will appear as follows: (Example) 700d OK 93.5% CODE-39 TEST
The number in the upper left indicates the number of times the decoder ran while scanning at 700 scans per second. The number can be lower than 700 when reading noisy barcodes. The upper right percentage indicates the ratio of the number of successful reads to the total number of attempts. By positioning the scanner at the optimal distance from the barcode with the correct orientation and with a grade-A quality barcode, readings of 95% or higher are expected. Reset the scanner after testing.
12
Page 22
Section 3 - Positioning the Scanner
V520-LHA7127
Application Notes Tips for Achieving High Throughput In some applications your primary objective may be to achieve the highest possible throughput rate. The following list identifies the parameters and scanner settings that can maximize scanning and decode throughput speed. Note By emphasizing maximum throughput, other areas of performance may be affected. For example, the number of non-reads could increase. If high throughput is critical, consider some or all of these settings: • Operate in the Trigger Disabled mode. Operation of the trigger can require as much as 200 msec before decoding begins, slowing down throughput rate. • Only enable those symbologies that you will be decoding. • Eliminate all suffixes and prefixes. • Minimize the number of redundant reads required before transmitting data. • Transmit the decoded data at the highest baud rate, 38,400 baud. • Disable buzzer functions. Tips for Insuring Highest Data Integrity There are several parameters that can enhance your confidence that the correct bar code data is transmitted. Note By emphasizing the accuracy and security of the data, other areas of the scanner operation may be affected. For example, you may not achieve the highest throughput. If accuracy and data integrity are critical, consider some or all of these settings: • Program the scanner to require a high number of redundant decodes prior to transmitting. For example, program the scanner to decode a bar code exactly the same way three consecutive times before transmitting the data. Then decoding the bar code the same way 2 out of 3 times or any 3 out of 4 times is not sufficient. It must obtain three consecutive and identical decodes. • Utilize a predetermined, fixed-length of bar code. Program the scanner to only decode a bar code of that length. Bar codes of any other length will be ignored. • The quality of the printed bar code must be excellent. • Use a bar code symbology that contains an internal check digit and program the scanner to calculate that check digit for validity prior to transmitting. • Do not use a symbology with poor internal verification, or subject to partial decodes, such as 2 of 5 or MSI/ Plessey. • Only enable those symbologies that you will be decoding. • Transmit data at low baud rates to minimize communication errors. Enable the “Number of Characters Transmitted.” The scanner will calculate and transmit a number indicating the total number of characters it is transmitting. Your host application program can compare this number with the actual number of characters received to verify that the correct amount of data is received.
13
Page 23
Section 3 - Positioning the Scanner
V520-LHA7127
Tips for Verifying the Presence of a Bar Code If the scanner is operated in the “trigger enabled” mode and the trigger is activated, one of three conditions may occur. A bar code is scanned and decoded
Decoded data is transmitted
A bar code is scanned but is not decoded (e.g., print quality was poor)
No data is transmitted
No bar code is present
No data is transmitted
In some applications, when no data is transmitted, it may be important to know why. Was there a bar code present that could not be decoded, or was no bar code present at all? This requirement is common in applications such as automated blood analysis equipment. Test tubes containing blood samples from many different people are loaded into a rack for automatic analysis. The bar code on each tube ties that sample and the results back to a specific individual. If no bar code data is transmitted it is critical to understand the reason. Your Omron scanner, when operated in the Trigger Enabled mode, can be programmed to transmit an error message indicating whether or not a bar code was present. The following table shows the message that will be transmitted for each condition. Presence/Absence of bar code Bar code was present and correctly decoded
Scanner Transmits Decoded Data
No bar code was present
<STX> “?” <ETX>
Bar code was present but could not be decoded
<STX> “>” <ETX>
14