Page 72
Appendix D - PLC/Touchscreen Connection Examples
V520-LHA7127
Appendix D PLC Connection Examples for Serial Trigger Sysmac PLC Series CPM2A, CPM2C, CJ1, CS1 (with serial ports providing 5V) 1 2 3 4 5 6
CPU unit PLC serial port Input module Bar code reader Programming console Trigger switch
CS1G/H - CPU xx Built into CPU C200H-ID xxx V500-LPx5627-P C200H-PR027-E -
■ Confirmation of Operation
■ Operation Switch ON trigger switch (6), shown above to execute V550 to read and send data to data memory of PLC. Use program console (5) to confirm the date. ■ V500-LPx5627-P Setup • Communication condition (setup) Baud rate:
9600 bps
Word length:
7 bits
Parity:
Even
Stop bit:
2 bits
• After programming, set the PLC to run on monitor mode. • Press the keys below in order if <password> is displayed. (1) CLR → (2) MONTR → (3) → CLR → (4) CLR • To see BCR data on program console: (1) CLR → (2) FUN → (3) MONTR ■ PLC Programming
• Trigger Requirements Start command
Z (fixed)
■ PLC Setup • Communication condition Set serial port for RS-232C (no protocol) • Setting start code Place the number SA00 into DM100 • Connection of trigger switch Connect a normally open switch to input 0000.00 of the input module to be able to initiate the BCR • BCR data will be placed in data memory starting at DM200 Note For multidrop RS422/485 connections, use K3SC converter at each BCR and set each BCR with unique prefix.
63
Page 73
Appendix D - PLC/Touchscreen Connection Examples
V520-LHA7127
PLC Connection Examples for External Trigger Sysmac PLC Series CPM2A, CPM2C, CJ1, CS1 (with serial ports providing 5V) 1 2 3 4 5 6 7
CS1G/H - CPUxx Built into CPU C200H-IDxxx V500-LPx5627-P C200H-PR027-E C200H-OCxxx
■ Confirmation of Operation
■ Operation Switch ON trigger switch (6), shown above to execute V550 to read and send data to data memory of PLC. Use program console (5) to confirm the date. ■ V500-LPx5627-P Setup • Communication condition (setup) Baud rate:
9600 bps
Word length:
7 bits
Parity:
Even
Stop bit:
2 bits
■ PLC Setup • Communication condition Set serial port for RS-232C (no protocol) • Connection of trigger switch Connect a normally open switch to input 0000.00 of the input module to be able to initiate the BCR • Connection of output to trigger BCR Connect external wires from BCR to relay output module 0001.00 of PLC (dry contact) • BCR data will be placed in data memory starting at DM200 Note For multidrop RS422/485 connections, use K3SC converter at each BCR and set each BCR with unique prefix.
64
CPU unit PLC serial port Input module Bar code reader Programming console Trigger switch Output module
• After programming, set the PLC to run on monitor mode. • Press the keys below in order if <password> is displayed. (1) CLR → (2) MONTR → (3) → CLR → (4) CLR • To see BCR data on program console: (1) CLR → (2) FUN → (3) MONTR ■ PLC Programming
Page 74
Appendix D - PLC/Touchscreen Connection Examples
V520-LHA7127
Touchscreen Connections Example 1 2
NT or NS Barcode reader
■ Operation On actuation of a string display on the screen, the barcode read from BCR will be displayed. ■ V500-LPx5627-P Setup • Add the STX prefix and ETX suffix to the data by scanning the codes in the operation manual of the BCR. • Set to “DISABLE” the trigger function and “MULTIPLE READ.” ■ NS/NT Setup • Verify that they communications parameters match the BCR: 9600 bps 7 data bits 2 stop bits EVEN parity • Create a screen with a “string display” on it and set its attributes to the bar code input.
65
Page 75
Appendix D - PLC/Touchscreen Connection Examples
66
V520-LHA7127
Page 76
Revision History A manual revision code appears as a suffix to the catalog number on the front cover of the manual.
Cat. No. Q07BAZ1
Revision code The following table outlines the changes made to the manual during each revision. Page numbers refer to the previous version. Revision code
Date
1
May 2003
Revised content Original production
67
Page 77
OMRON ELECTRONICS LLC 1 Commerce Drive Schaumburg, IL 60173 847.843.7900 For US technical support or other inquiries: 800.556.6766
OMRON CANADA, INC. 885 Milner Avenue
Toronto, Ontario M1B 5V8 416.286.6465
OMRON ON-LINE Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.ca
Q07BAZ1 5/03/100
©2003 OMRON ELECTRONICS LLC Printed in the U.S.A.
Specifications subject to change without notice.