The text of a spec sheet · part 2 of 2
MicroSafe MC4700, MCF4700 and MCJ4700 Safety Light Curtains, pages 10 to 18
Pages 10 to 18 of 18
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Omron MC4700
Page 10
MC4700, MCF4700 and MCJ4700
MicroSafe Flexible MCF4700 Dimensions A mm/in.
B mm/in.
MCF4700-14, MCF4700-20 and MCF4700-30
MCF4700-12
C mm/in.
A mm/in.
B mm/in.
C mm/in.
First, Middle Segment
First, Middle Segment
A mm/in.
B mm/in.
C mm/in.
Last Segment
102/4.0
185/7.3
214/8.4
159/6.3
242/9.5
271/10.7
159/6.3
226/8.9
255/10.0
202/8.0
285/11.2
314/12.4
*235/9.3
318/12.5
347/13.7
*235/9.3
302/11.9
331/13.0
302/11.9
385/15.2
414/16.3
309/12.2
392/15.4
421/16.6
309/12.2
376/14.8
405/15.9
*385/15.2
468/18.4
497/19.6
*385/15.2
452/17.8
481/18.9
485/19.1
514/20.2
502/19.8
585/23.0
614/24.2
459/18.1
542/21.3
571/22.5
459/18.1
526/20.7
555/21.9
602/23.7
685/27.0
714/28.1
*535/21.1
618/24.3
647/25.5
*535/21.1
602/23.7
631/24.8
702/27.6
785/30.9
814/32.0
609/24.0
692/27.2
721/28.4
609/24.0
676/26.6
705/27.8
768/30.2
797/31.4
D
802/31.6
885/34.8
914/36.0
*685/27.0
*685/27.0
752/29.6
781/30.7
902/35.5
985/38.8
1014/39.9
759/29.9
842/33.1
871/34.3
759/29.9
826/32.5
855/33.7
1002/39.5
1085/42.7
1114/43.9
*835/32.9
918/36.1
947/37.3
*835/32.9
902/35.5
931/36.7
1102/43.4
1185/46.7
1214/47.8
909/35.8
992/39.1
1021/40.2
909/35.8
976/38.4
1005/39.6
*985/38.9
1068/42.0
1097/43.2
Last Segment
*985/38.9
1052/41.4
1081/42.6
102/4.0
169/6.7
198/7.8
1059/41.7
1142/45.0
1171/46.1
1059/41.7
1126/44.3
1155/45.5
202/8.0
269/10.6
298/11.7
*1135/44.7
1218/48.0
1247/49.1
*1135/44.7
1202/47.3
1231/48.5
302/11.9
369/14.5
398/15.7
1209/47.6
1292/50.9
1321/52.0
1209/47.6
1276/50.2
1305/51.4
1368/53.9
1397/55.0
402/15.8
469/18.5
498/19.6
*1285/50.6
*1285/50.6
1352/53.2
1381/54.4
502/19.8
569/22.4
598/23.5
1359/53.5
1442/56.8
1471/57.9
1359/53.5
1426/56.1
1455/57.3
602/23.7
669/26.3
698/27.5
*1435/56.5
1518/59.8
1547/60.9
*1435/56.5
1502/59.1
1531/60.3
702/27.6
769/30.3
798/31.4
1509/59.4
1592/62.7
1621/63.8
1509/59.4
1576/62.0
1605/63.2
1668/65.7
1697/66.8
802/31.6
869/34.2
898/35.4
*1585/62.4
*1585/62.4
1652/65.0
1681/66.2
902/35.5
969/38.1
998/39.3
1659/65.3
1742/68.6
1771/69.7
1659/65.3
1726/68.0
1755/69.1
1002/39.5
1069/42.1
1098/43.2
*1735/68.3
1818/71.6
1847/72.7
*1735/68.3
1802/70.9
1831/72.1
1102/43.4
1169/46.0
1198/47.2
1809/71.2
1892/74.5
1921/75.6
1809/71.2
1876/73.9
1905/75.0
* Not available in 30 mm resolution
Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
For the Latest Information On the Internet: www.sti.com or www.omron.ca
D29 safety light curtains
402/15.8
Page 11
MC4700, MCF4700 and MCJ4700
■
Ordering for MCF4700 Series
To order a MicroSafe Flexible system, simply fill in the fields in the model number sequence given below. Each field is numbered and information on completing a specific field can be found in the sections which follow.
safety light curtains
D
✎
For specifications and dimensions on the LCM Series Controller, see page D106
___ - __ __ - __ __ - __ __ - ___ -___X - ___R - ___XI - ___RI - ___ 1 2 3 2 3 2 3 4 5 5 6 6 7 Example: MCF47-12300-30900-20300-LCM1-10X-10R-030100XI-030100RI-RM1 This system has a 12 mm minimum object resolution and 302 mm long first segment, 30 mm minimum object resolution and 909 mm long middle segment and a 20 mm minimum object resolution and 309 mm long last segment, an LCM1 controller, 10 m transmitter and receiver cables, a 3 m and a 10 m interconnect transmitter and receiver cables, and an RM-1 relay output module. 1 Information required. Indicates if the MCF4700 is used in ESD sensitive applications may require manufacturing to low ESD requirements. This option is typically required where the build-up of an electrostatic charge on the light curtain and its subsequent discharge could harm the product being produced by the guarded machine (i.e. integrated circuits, disk drives, electronic components, etc.). On low ESD systems, transmitters and receivers are nickel plated and other modifications are incorporated. Designator
Description
MCF47
MicroSafe Flexible system
MCF47S
Low ESD MicroSafe Flexible system
2 Information required. Represents the minimum object resolution of each transmitter and receiver pair in millimeters. Designators are described below. It is possible to order different object resolutions for each pair of segments. Designator
Minimum Object Resolution
12
12 mm (0.47 in.)
14
14 mm (0.55 in.)
20
20 mm (0.79 in.)
30
30 mm (1.18 in.)
3 Information required. Represents the protection height of each transmitter and receiver pair in a system. The MCF4700 series must have a minimum of two segments: one first and one end. It is possible to order a different object resolution for each pair of segments. Up to two middle segments can be added. The total protected height of a system cannot exceed 256 beams or 3450 mm (135.8 in.).
Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 D30
Combine the designators given here to complete fields 2 and 3 in the model sequence. 12 mm Minimum Object Resolution Systems Designator # Beams
Protection Height
100
16
102 mm (4.0 in.)
200
32
202 mm (8.0 in.)
300
48
302 mm (11.9 in.)
400
64
402 mm (15.8 in.)
500
80
502 mm (19.8 in.)
600
96
602 mm (23.7 in.)
700
112
702 mm (27.6 in.)
800
128
802 mm (31.6 in.)
900
144
902 mm (35.5 in.)
1000
160
1002 mm (39.5 in.)
1100
176
1102 mm (43.4 in.)
14 mm, 20 mm or 30 mm Minimum Object Resolution Systems Designator # Beams
Protection Height
150
14/7
159 mm (6.3 in.)
225***
21
235 mm (9.3 in.)
300
28/14
309 mm (12.2 in.)
375***
35
385 mm (15.2 in.)
450
42/21
459 mm (18.1 in.)
525***
49
535 mm (21.1 in.)
600
56/28
609 mm (24.0 in.)
675***
63
685 mm (27.0 in.)
750
70/35
759 mm (29.9 in.)
825***
77
835 mm (32.9 in.)
900
84/42
909 mm (35.8 in.)
975***
91
985 mm (38.8 in.)
1050
98/49
1059 mm (41.7 in.)
1125***
105
1135 mm (44.7 in.)
1200
112/56
1209 mm (47.6 in.)
1275***
119
1285 mm (50.6 in.)
1350
126/63
1359 mm (53.3 in.)
1425***
133
1435 mm (56.5 in.)
1500
140/70
1509 mm (59.4 in.)
1575***
147
1585 mm (62.4 in.)
1650
154/77
1659 mm (65.3 in.)
1725***
161
1735 mm (68.3 in.)
1800
168/84
1809 mm (71.2 in.) Go to the Engineering Guide *** Not available in 30 mm resolution
For the Latest Information On the Internet: www.sti.com or www.omron.ca
A
For in-depth information on safety standards and use.
Page 12
MC4700, MCF4700 and MCJ4700
4 Information required. Represents controller version. Designators and descriptions are given below. Designator
Description
LCM1
DIN-mount, IP20, solid-state safety output, 24 VDC
LCM2
DIN-mount, IP20, solid-state safety output, 24 VDC, DeviceNet interface
LCM3
DIN-mount, IP20, solid-state safety output, 24 VDC, non-CE-marked, multiple stored Metal enclosure, IP65, relay safety output, 100-230 VAC
LCM200
Metal enclosure, IP65, relay safety output, 100-230 VAC, DeviceNet interface
LCM300
Metal enclosure, IP65, relay safety output, 100-230 VAC, non-CE-marked, multiple stored channel select patterns
LCM110
Metal enclosure, IP65, relay safety output, 100-230 VAC, lid-mounted reset switch
LCM210
Metal enclosure, IP65, relay safety output, 100-230 VAC, lid-mounted reset switch, DeviceNet interface
LCM310
Metal enclosure, IP65, relay safety output, 100-230 VAC, lid-mounted reset switch, non-CE marked, multiple stored channel select patterns
LCM120
Metal enclosure, IP65, solid-state safety output, 24 VDC
LCM220
Metal enclosure, IP65, solid-state safety output, 24 VDC, DeviceNet interface
LCM320
Metal enclosure, IP65, solid-state safety output, 24 VDC, non-CE-marked, multiple stored channel select patterns
LCM130
Metal enclosure, IP65, solid-state safety output, 24 VDC, lid-mounted reset switch
LCM230
Metal enclosure, IP65, solid-state safety output, 24 VDC, lid-mounted reset switch, DeviceNet interface
LCM330
Metal enclosure, IP65, solid-state safety output, 24 VDC, lid-mounted reset switch, non-CE marked, multiple stored channel select patterns
LCM140
Metal enclosure, IP65, relay safety output, 24 VDC
LCM240
Metal enclosure, IP65, relay safety output, 24 VDC, DeviceNet interface
LCM340
Metal enclosure, IP65, relay safety output, 24 VDC, non-CE-marked, multiple stored channel select patterns
Designator Interconnect Cable
LCM150
Metal enclosure, IP65, relay safety output, 24 VDC, lid-mounted reset switch
(Blank)
Standard 150 mm (6 in.)
LCM250
Metal enclosure, IP65, relay safety output, 24 VDC, lid-mounted reset switch,
003
0.3 m (12 in.)
DeviceNet interface
005
0.5 m (20 in.)
Metal enclosure, IP65, relay safety output, 24 VDC, lid-mounted reset switch, non‑
010
1 m (3.3 ft.)
CE marked, multiple stored channel select patterns
020
2 m (6.6 ft.)
030
3 m (10 ft.)
050
5 m (16 ft.)
100
10 m (33 ft.)
LCM350
Note: For more configurations with quick-disconnect connectors refer to the LCM controller section.
5 Information required. Represents transmitter (X) and receiver (R) cable lengths. Designators and descriptions are given below. Designator
Description
3
3 m (10 ft.)
10
10 m (33 ft.)
30
30 m (99 ft.)
Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
For the Latest Information On the Internet: www.sti.com or www.omron.ca
D31
D safety light curtains channel select patterns LCM100
6 Information required. Represents transmitter and receiver interconnect cable lengths. The MCF4700 series segments feature an in-line connector cable design. A flexible 150 mm (6 in.) cable is always supplied between each segment. Length of interconnect cables given below are in addition to this standard cable. The maximum cumulative system length, including the cables is 15 m (49 ft.) for the transmitter and 15 m (49 ft.) for the receiver. The transmitter and receiver interconnect cable lengths do not need to match. Combine the designators listed below to complete both fields numbered 6 in the example. The combination for a threesegment system might look like 030. This means that the system uses only the standard 150 mm (6 in.) cables between two of the segments and a 3 m (10 ft.) interconnect cable between the other segments.
Page 13
MC4700, MCF4700 and MCJ4700
■
Ordering for MCF4700 Series (cont.)
7 Information optional. Indicate if you would like an Omron STI RM Series resource module.
safety light curtains
D
Designator
Description
RM1
Include RM-1 resource module, force-guided relay output
RM3
Include RM-3 resource module, mute module
RM4
Include RM-4 resource module, allow for wiring up to four MC4700 systems
RMX
Include RM-X resource module
(Blank)
No RM series resource module information on Resource ✎ For Modules, see page D138 information on safety light ✎ For curtain accessories, see page D184
Safety Standards and Precautions All models of the MicroSafe meet ANSI/RIA R15.06-1999, ANSI B11.19-2003. When used with mechanical power presses, OSHA industrial safety standards apply, as stated in 1910.217(c). For other applications, the machine guarding requirements found in section 1910.212 apply. The MicroSafe meets ANSI control reliability requirements for point-of-operation presence sensing devices. All controllers have CSA-CUS acceptance and are designed to meet UL508. MicroSafe systems employing LCM controllers (except those with the ability to store multiple channel select patterns) have been EC type examined to the requirements of category 4, EN 954-1 (type 4, IEC 61496). The MicroSafe should only be used on machinery that can consistently and immediately stop anywhere in its cycle or stroke. Never use a MicroSafe on a full revolution clutched power press or machine. If the light curtain does not protect all access to the point of operation, the unprotected access must be guarded by other appropriate devices such as mechanical guards. The purchaser, installer and employer have the responsibility to meet all local, state and federal government laws, rules, codes or regulations relating to the proper use, installation, operation and maintenance of this control and the guarded machine. See the Installation and Operation Manual for additional information. All application examples described are for illustration purposes only. Actual installations will differ from those indicated.
A Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 D32
For the Latest Information On the Internet: www.sti.com or www.omron.ca
Go to the Engineering Guide For in-depth information on safety standards and use.
Page 14
MC4700, MCF4700 and MCJ4700
■
Dimensions for MCJ4700 Series - mm/in. 37.1 1.46 16.0 0.63 enDcAP JOint #1 28.0 1.10 dimensions on the LCM Series ✎ For Controller, see page D106
26.0 1.02
28.0 1.10 5.2 thru 0.21 hole
24.9 0.98
A
23.1 0.91 enDcAP JOint #2 38.4 1.51
52.0 2.05 enDcAP JOint #2
3.8 0.15 miD Segment firSt Segment safety light curtains
9.1 0.36
D c
B
30.0 1.18
38.6 1.52 enDcAP JOint #1
41.0 1.61
SiDe VieW frOnt VieW lASt Segment
MicroSafe Jointed MCJ4700 Dimensions MCJ4700-12
MCJ4700-14, MCJ4700-20 and MCJ4700-30
MCJ4700-14, MCJ4700-20 and MCJ4700-30
A, B & C mm/in.
A mm/in.
B & C mm/in.
FIRST, MIDDLE & LAST SEGMENTS
FIRST SEGMENT ONLY
MIDDLE AND LAST SEGMENTS
102/4.0
159/6.3
*78/3.0
202/8.0
*235/9.3
152/6.0
302/11.9
309/12.2
*228/9.0
402/15.8
*385/15.2
302/11.9
502/19.8
459/18.1
*378/14.9
602/23.7
*535/21.1
452/17.8
702/27.6
609/24.0
*528/20.8
802/31.6
*685/27.0
602/23.7
902/35.5
759/29.9
*678/26.7
1002/39.5
*835/32.9
752/29.6
909/35.8
*828/32.6
1102/43.4
*985/38.8
902/35.5
1059/41.7
*978/38.5
*1135/44.7
1052/41.4
1209/47.6
*1128/44.4
*1285/50.6
1202/47.3
1359/53.5
*1278/50.3
*1435/56.5
1352/53.2
1509/59.4
*1428.0/56.2
*1585/62.4
1502/59.1
1659/65.3
*1578/62.1
*1735/68.3
1652/65.0
1809/71.2
*1728/68.0
*Not available in 30 mm resolution.
1802/70.9 *Not available in 30 mm resolution.
Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
For the Latest Information On the Internet: www.sti.com or www.omron.ca
D33
Page 15
MC4700, MCF4700 and MCJ4700
90° Jointed MicroSafe MCJ4700 Dimensions - mm/in.
e D A2
D safety light curtains
29.8 1.13 15.8 0.62
55.0 2.17 41.4 1.63
A1
14.8 0.58 9.3 0.37
A first cABle mid 15.0 0.59 B2 last remOVABle PlUg (X4) USe m5 ScreW
B1
14.8 0.58
B
9.3 0.37 f cABle 33.5 1.33
15.8 0.62 29.8 1.13
15.0 0.59
25.9 1.02 39.5 1.55 c c1 m3 ShcS (X4)
c2
Mounting dimension formulas based on detection zones A, B, C A = Detection Zone (First Segment) A1 = A + 50.7 mm (1.99 in.) (mtg holes) A2 = A + 69.8 mm (2.75 in.) B = Detection Zone (Middle Segment) B1 = B + 25.1 mm (0.99 in.) (mtg holes) B2 = B + 44.6 mm (1.76 in.) C = Detection Zone (Last Segment) C1 = C + 41.7 mm (1.64 in.) (mtg holes) C2 = C + 68.9 mm (2.72 in.) D = A1 + C1 – 15.0 mm (0.59 in.) (mtg holes) E = A2 + C2 – 33.5 mm (1.32 in.) F = B1 – 15.0 mm (0.59 in.) (mtg holes)
A Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 D34
For the Latest Information On the Internet: www.sti.com or www.omron.ca
Go to the Engineering Guide For in-depth information on safety standards and use.
Page 16
MC4700, MCF4700 and MCJ4700
■
Ordering for MCJ4700 Series
To order a 90° Jointed MicroSafe system, simply fill in the fields in the model number sequence given below. Each field is numbered and information on completing a specific field can be found in the sections which follow. It is possible to order a different object resolution for each pair of segments.
MCJ47-___ ___ - ___ ___ -___ ___ - ___ - ___X - ___R - ___ 1 2 3 2 3 2 3 4 5 5 6 Example: MCJ47-12200-20450-301650-LCM1-10X-30R-RM1 This system has a 12 mm minimum object resolution and 202 mm long first segment, a 20 mm minimum object resolution and 459 mm long middle segment, a 30 mm minumum object resolution and 1959 mm long last segment, an LCM1 controller, a 10 m transmitter and 30 m receiver cable and an RM-1 relay output module.
1 Information required. Indicates if the MicroSafe system is manufactured to low ESD requirements. This option is typically required where the build-up of an electrostatic charge on the light curtain and its subsequent discharge could harm the product being produced by the guarded machine (i.e. integrated circuits, disk drives, electronic components, etc.). On low ESD systems, transmitters and receivers are nickel plated and other modifications are incorporated. Designators are described below. Designator
Description
MCJ47
Standard MicroSafe system
MCJ47S
Low ESD MicroSafe system
Protection Height
100
16
102 mm (4.0 in.)
200
32
202 mm (8.0 in.)
300
48
302 mm (11.9 in.)
400
64
402 mm (15.8 in.)
500
80
502 mm (19.8 in.)
600
96
602 mm (23.7 in.)
700
112
702 mm (27.6 in.)
800
128
802 mm (31.6 in.)
900
144
902 mm (35.5 in.)
1000
160
1002 mm (39.5 in.)
1100
176
1102 mm (43.4 in.)
First Segment ONLY of 14, 20 or 30 mm Minimum Object Resolution Systems # Beams Desig. (14&20/30 mm) Protection Height 150
14/7
159 mm (6.3 in.)
225*
21/*
235 mm (9.3 in.)
300
28/14
309 mm (12.2 in.)
375*
35/*
385 mm (15.2 in.)
450
42/21
459 mm (18.1 in.)
525*
49/*
535 mm (21.1 in.)
600
56/28
609 mm (24.0 in.)
675*
63/*
685 mm (27.0 in.)
Minimum Object Resolution
750
70/35
759 mm (29.9 in.)
12
12 mm (0.47 in.)
825*
77/*
835 mm (32.9 in.)
14
14 mm (0.55 in.)
900
84/42
909 mm (35.8 in.)
20
20 mm (0.79 in.)
975*
91/*
985 mm (38.8 in.)
30
30 mm (1.18 in.)
1050
98/49
1059 mm (41.7 in.)
1125*
105/*
1135 mm (44.7 in.)
1200
112/56
1209 mm (47.6 in.)
1275*
119/*
1285 mm (50.6 in.)
1350
126/63
1359 mm (53.3 in.)
1425*
133/*
1435 mm (56.5 in.)
1500
140/70
1509 mm (59.4 in.)
1575*
147/*
1585 mm (62.4 in.)
1650
154/77
1659 mm (65.3 in.)
1725*
161/*
1735 mm (68.3 in.)
1800
168/84
1809 mm (71.2 in.)
2 Information required. Represents the minimum object resolution of each transmitter and receiver pair. Designators are described below. Designator
3 Information required. Represents the protection height of all transmitter and receiver segments in a system. MicroSafe MCJ4700 Series light curtains must have a minimum of two segments one first and one last. The total protected height of a system cannot exceed 256 beams or 3450 mm (135.8 in.).
Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D safety light curtains specifications and dimensions on the LCM ✎ For Series Controller, see page D106
12 mm Minimum Object Resolution Systems Designator # Beams
* Not available in 30 mm resolution
For the Latest Information On the Internet: www.sti.com or www.omron.ca
D35
Page 17
MC4700, MCF4700 and MCJ4700
■
Ordering for MCJ4700 Series (continued)
Mid and Last Segment of 14, 20 or 30 mm Minimum Object Resolution Systems
4 Information required. Represents controller version. Designators and descriptions are given below.
# Beams safety light curtains
D
Designator (20/30 mm) Protection Height
Designator
Description
075*
7/*
78 mm (3.1 in.)
LCM1
DIN-mount, IP20, solid-state safety output, 24 VDC
150
14/7
152 mm (6.0 in.)
LCM2
DIN-mount, IP20, solid-state safety output, 24 VDC, DeviceNet interface
225*
21/*
228 mm (9.0 in.)
LCM3
DIN-mount, IP20, solid-state safety output, 24 VDC, non-CE-marked, multiple stored
300
28/14
302 mm (11.9 in)
375*
35/*
378 mm (14.9 in.)
LCM100
Metal enclosure, IP65, relay safety output, 100-230 VAC
450
42/21
452 mm (17.8 in.)
LCM200
Metal enclosure, IP65, relay safety output, 100-230 VAC, DeviceNet interface
525*
49/*
528 mm (20.8 in.)
LCM300
Metal enclosure, IP65, relay safety output, 100-230 VAC, non-CE-marked, multiple
600
56/28
602 mm (23.7 in.)
675*
63/*
678 mm (26.7 in.)
LCM110
Metal enclosure, IP65, relay safety output, 100-230 VAC, lid-mounted reset switch
750
70/35
752 mm (29.6 in.)
LCM210
Metal enclosure, IP65, relay safety output, 100-230 VAC, lid-mounted reset switch,
825*
77/*
828 mm (32.6 in.)
900
84/42
902 mm (35.5 in.)
975*
91/*
978 mm (38.5 in.)
1050
98/49
1052 mm (41.4 in.)
LCM120
Metal enclosure, IP65, solid-state safety output, 24 VDC
1125*
105/*
1128 mm (44.4 in.)
LCM220
Metal enclosure, IP65, solid-state safety output, 24 VDC, DeviceNet interface
1200
112/56
1202 mm (47.3 in.)
LCM320
Metal enclosure, IP65, solid-state safety output, 24 VDC, non-CE-marked, multiple
1275*
119/*
1278 mm (50.3 in.)
1350
126/63
1352 mm (53.2 in.)
LCM130
Metal enclosure, IP65, solid-state safety output, 24 VDC, lid-mounted reset switch
1425*
133/*
1428 mm (56.2 in.)
LCM230
Metal enclosure, IP65, solid-state safety output, 24 VDC, lid-mounted reset switch,
1500
140/70* 1502 mm (59.1 in.)
1575*
147/*
1650
154/77* 1652 mm (65.0 in.)
1725*
161/*
1728 mm (68.0 in.)
LCM140
Metal enclosure, IP65, relay safety output, 24 VDC
1800
168/84
1802 mm (70.9 in.)
LCM240
Metal enclosure, IP65, relay safety output, 24 VDC, DeviceNet interface
LCM340
Metal enclosure, IP65, relay safety output, 24 VDC, non-CE-marked, multiple stored
1578 mm (62.1 in.)
* Not available in 30 mm resolution channel select patterns stored channel select patterns
DeviceNet interface LCM310
Metal enclosure, IP65, relay safety output, 100-230 VAC, lid-mounted reset switch, non-CE marked, multiple stored channel select patterns stored channel select patterns
DeviceNet interface LCM330
Metal enclosure, IP65, solid-state safety output, 24 VDC, lid-mounted reset switch, non-CE marked, multiple stored channel select patterns channel select patterns LCM150
Metal enclosure, IP65, relay safety output, 24 VDC, lid-mounted reset switch
LCM250
Metal enclosure, IP65, relay safety output, 24 VDC, lid-mounted reset switch, DeviceNet interface
LCM350
Metal enclosure, IP65, relay safety output, 24 VDC, lid-mounted reset switch, non‑ CE marked, multiple stored channel select patterns
Note: For more configurations with quick-disconnect connectors refer to the LCM controller section.
5 Information required. Represents transmitter (X) and receiver (R) cable lengths. Designators and descriptions are given below. Designator
Description
3
3 m (10 ft.)
10
10 m (33 ft.)
30
30 m (99 ft.)
Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 D36
For the Latest Information On the Internet: www.sti.com or www.omron.ca
A
Go to the Engineering Guide For in-depth information on safety standards and use.
Page 18
MC4700, MCF4700 and MCJ4700
6 Information optional. Indicate if you would like an Omron STI RM Series resource module. Designator
Description
RM1
Include RM-1 resource module, force-guided relay Include RM-3 resource module, mute module
RM4
Include RM-4 resource module, allow for wiring up to four MC4700 systems
RMX
Include RM-X resource module
(Blank)
No RM series resource module information on Resource ✎ For Modules, see page D138 information on safety light ✎ For curtain accessories, see page D184
Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
For the Latest Information On the Internet: www.sti.com or www.omron.ca
D37
D safety light curtains output RM3
Safety Standards and Precautions All models of the MicroSafe meet ANSI/RIA R15.06-1999, ANSI B11.19-2003. When used with mechanical power presses, OSHA industrial safety standards apply, as stated in 1910.217(c). For other applications, the machine guarding requirements found in section 1910.212 apply. The MicroSafe meets ANSI control reliability requirements for point-of-operation presence sensing devices. All controllers have CSA-CUS acceptance and are designed to meet UL508. MicroSafe systems employing LCM controllers (except those with the ability to store multiple channel select patterns) have been EC type examined to the requirements of category 4, EN 954-1 (type 4, IEC 61496). The MicroSafe should only be used on machinery that can consistently and immediately stop anywhere in its cycle or stroke. Never use a MicroSafe on a full revolution clutched power press or machine. If the light curtain does not protect all access to the point of operation, the unprotected access must be guarded by other appropriate devices such as mechanical guards. The purchaser, installer and employer have the responsibility to meet all local, state and federal government laws, rules, codes or regulations relating to the proper use, installation, operation and maintenance of this control and the guarded machine. See the Installation and Operation Manual for additional information. All application examples described are for illustration purposes only. Actual installations will differ from those indicated.