The text of a spec sheet · part 1 of 2
MicroSafe MC4700, MCF4700 and MCJ4700 Safety Light Curtains, pages 1 to 9
Pages 1 to 9 of 18
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Omron MC4700
Page 1
MC4700, MCF4700 and MCJ4700
MCF4700 Series
MC4700 Series
R
C
US
C
US
File No. LR90200
MCF4700 Series ■
D
Segmented lengths from 100 to 1800 mm (3.9 to 70.9 in.). Segments are connected by interconnect cables.
MCJ4700 Series
MCJ4700 Series safety light curtains
■
Segmented lengths from 75 mm (3.0 in.) to 1800 mm (71.0 in.). Electro/mechanical joints link the segments at a 90° angle.
Options ■ ■
DeviceNet™ Interface Low ESD models. Consult factory.
■
Muting through RM-3 module
■
Description
LCM Series Controllers
MicroSafe
®
MC4700, MCF4700 and MCJ4700 ■
■
■
■
■
■
Ultra-compact 26 x 28 mm (1.0 x 1.1 in.) transmitter and receiver;
■
Excellent resolutions of 12, 14, 20 and 30 mm Protected heights from 100 to 1800 mm (3.9 to 70.9 in.)
■
Available outputs: – 2 PNP safety outputs – 1 N.O. and 1 N.O./N.C. safety relay output – 2 auxiliary outputs (1 NPN, 1 PNP), follow or alarm mode Individual Beam Indicators Exact channel select and floating blanking
Two-digit diagnostics display visible on controller
■
Choice of operating modes – Automatic Start – Restart Interlock – Start/Restart Interlock
■
MPCE monitoring
■
In-line connector cables
■
Adjustable mounting brackets
Available enclosures: – 100 mm DIN enclosure with removable terminal blocks – IP65-rated lockable metal enclosure
Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 D20
The MicroSafe 4700 series is unique due to superior response time – as fast as 6.69 msec – and excellent resolution of 12 mm. This combination of speed and resolution allow this ultra-compact light curtain to be mounted closer to the point of hazardous operation. The MicroSafe MC4700 series consists of an identical length transmitter and receiver, combined with an LCM series controller and appropriate cables. The ultra-compact transmitter and receiver dimensions allow the MicroSafe to be mounted on small automatic assembly machines and in other applications where space is at a premium. The in-line connector cables allow the mounting of the transmitter and receiver in crowded locations where a standard connector notGuide fit. Go towould the Engineering For of in-depth The controller end theinformation cable onis
A
For the Latest Information On the Internet: www.sti.com or www.omron.ca safety standards and use.
Page 2
MC4700, MCF4700 and MCJ4700
DeviceNet Option The LCM series controller is available with an optional DeviceNet™ interface. DeviceNet™ allows the LCM series controller to communicate non-safety-related data across this popular fieldbus. As the de facto standard for factory fieldbus communications, DeviceNet™ is widely employed in the automotive, semiconductor and other industries. Monitoring of a DeviceNet™ equipped light curtain provides the process control system with the following non-safety information: manufacturer, product name, operating mode, detection zone status, safety output status, MPCE monitoring enabled/disabled, floating blanking active/inactive, exact channel select active/inactive, transmitter, receiver, controller, and relay faults, error codes and descriptions. DeviceNet™ and the LCM series controller provide a powerful automation solution.
■
Applicable Controllers
The LCM controller includes virtually every desirable safety light curtain feature. There are two options available: DeviceNet™ interface, and a multi-channel select (not CE marked) version capable of storing up to eight selected patterns. ■
Applications
MC4700 Application Due to its small dimensions, the MicroSafe can be elegantly integrated into table-top automated production equipment. Its in-line connector cables allow it to be mounted in tight, confined spaces. Since cable length can be shortened in the field, it is easy for OEM equipment builders to achieve a custom, built-in look.
MCJ4700 Application In this application the light curtain is not visible. With the creation of a jointed-segmented MCJ4700, an OEM has the ability to truly build the light curtain into their product. The OEM or integrator is able to apply a CE marked safety solution that meets world-wide standards. With a small size housing of 26 mm x 28 mm (1.0 x 1.1 in.), the ability to mount on a single plane, and segment increments as small as 75 mm (2.95 in.), the MCJ4700 provides the cleanest, most elegant safety solution.
MCF4700 Application Here, a three-segment MicroSafe Flexible series system forms a “U-shaped” guard zone to protect all unguarded sides of a small machine. Without the MicroSafe Flexible, mirrors or three conventional safety light curtains would have to be used.
Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
For the Latest Information On the Internet: www.sti.com or www.omron.ca
D21
D safety light curtains not terminated, which allows the length to be easily shortened in the field. The MCF4700 consists of at least two transmitter and receiver segments, combined with an LCM series controller and appropriate interconnecting cables. The MicroSafe MCJ4700 also consists of at least two transmitter and receiver segments, mechanically linked at a 90° angle. Interconnect cables are not required. For easy alignment, the MicroSafe series features Omron STI’s patented Individual Beam Indicator lights.
Page 3
MC4700, MCF4700 and MCJ4700
■
Specifications for Transmitter and Receiver
Performance Protected Height:
safety light curtains
D
12 mm, 100 to 1200 mm (3.9 to 62.9 in.) in 100 mm increments 14 mm, 150 to 1800 mm (5.9 to 71.2 in.) in 75 mm increments
20 mm, 150 to 1800 mm (5.9 to 71.2 in.) in 75 mm increments
30 mm, 150 to 1800 mm (5.9 to 71.2 in.) in 150 mm increments
Operating Range:
MC47SR and MC47SRS; MCF47 and MCF47S; MCJ47 and MCJ47S 12 mm, 0.2 to 3 m (0.7 to 10 ft.)
14 mm, 0.3 to 5 m (1 to 17 ft.) for MC4700 and MCJ4700; 14 mm, 0.3 to 3 m (1 to 10 ft.) for MCF4700
20 mm, 0.3 to 7 m (1 to 23 ft.)
30 mm, 0.3 to 7 m (1 to 23 ft.)
MC47LR and MC47LRS
12 mm, 0.2 to 5 m (0.7 to 17 ft.)
20 mm, 0.3 to 12 m (1 to 39 ft.)
30 mm, 0.3 to 12 m (1 to 39 ft.)
Resolution:
12 mm, 0.47 in.*
14 mm, 0.55 in.*
20 mm, 0.79 in.*
30 mm, 1.2 in.*
* Use of exact channel select and/or floating blanking may increase this value.
Effective Aperture Angle: ±2.5° transmitter and receiver Light Source: 850 nm LED Light Source Life: 100,000 hours Indicators: Channel Select or Floating blanking – amber; Interlock or Fault – yellow; Machine Stop – red, Individual Beam Indicators – red; Machine Run – green. Mechanical Enclosure: IP65 transmitter and receiver enclosure. Polyurethane powder-painted aluminum yellow. Cable Length:
Transmitter – maximum 30 m (100 ft.); standard 3 m (10 ft.)
Receiver – maximum 30 m (100 ft.); standard 3 m (10 ft. )
*For MCF4700 Series: Interconnect cables are available from 0.3 m (12 in.) to 10 m (33 ft.). Maximum total length of a system is 15 m
(49 ft.). Consult factory for longer lengths.
Cable Connections: Circular style, 5-conductor for transmitter, 8-conductor for receiver Environmental Protection Rating: Transmitter and receiver – IP65; Available controllers: 35 mm DIN mount - IP20, Metal Chassis - IP65 (for more information see the LCM Series section) Operating Temperature: 0 to 55°C (32 to 133°F) Storage Temperature: -25 to 75°C (-13 to 167°F) Relative Humidity: 95% maximum, non-condensing Vibration: 5–60 Hz maximum on all 3 axes Shock: 10 g for 0.016 seconds; 1,000 shocks for each axis on two axis Conformity Tested To/Approvals Approvals: IEC61496, CE Mark Conforming to Standards: ANSI/RIA R15.06-1999, ANSI B11.19-2003, OSHA 1910.27(c), OSHA 1910.212 Other Approvals: All MC4700 systems have been EC type examined to the requirements of IEC 61496-1, -2 for a Type 4 ESPE. Registration Go toTUV the Engineering Guide Number: BB201132801, BB211167401, BB221006201. CSA Certificate 1289466. UL listed. Specifications are subject to change without notice. Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 D22
For the Latest Information On the Internet: www.sti.com or www.omron.ca
A
For in-depth information on safety standards and use.
Page 4
MC4700, MCF4700 and MCJ4700
■
Dimensions for MC4700 Series - mm/in. 41.4 [1.63] dimensions on the LCM Series ✎ For Controller, see page D106 SlOtS
DimenSiOnS:
16.7 lg X 6.8 DiA 0.27 0.66
44.3 [1.74]
28.0 [1.10]
25.9 [1.02]
31.0 [1.22]
14.2 [0.56]
D mm (+\-.3)
12.2 0.48
40.5 [1.59]
1.02 [26.0]
30.3 [1.19]
"A" DetectiOn ZOne
"B" safety light curtains incheS (+\-.01)
"c"
42.8 1.68
56.0 [2.20] A = DetectiOn ZOne B=A+ c=A+
O.D.
41.4 [1.63]
67.2 +/- 5.0 2.65 +/- 0.20 96.5
14.2 0.56 frOnt VieW
3.80
7.0 DiA. 0.28 cl
27.3 c 1.08 l
SiDe VieW
MicroSafe MC4700 Dimensions
MC4700-12
MC4700-14 and MC4700-20
MC4700-30
A mm/in.
B mm/in.
C mm/in.
A mm/in.
B mm/in.
C mm/in.
A mm/in.
B mm/in.
C mm/in.
102/4.0
169/6.7
198/7.8
159/6.3
226/8.9
255/10.0
159/6.3
226/8.9
255/10.0
202/8.0
269/10.6
298/11.7
235/9.3
302/11.9
331/13.0
309/12.2
376/14.8
405/15.9
302/11.9
369/14.5
398/15.7
309/12.2
376/14.8
405/15.9
459/18.0
526/20.7
555/21.9
402/15.8
469/18.5
498/19.6
385/15.2
452/17.8
481/18.9
609/24.0
676/26.6
705/27.8
502/19.8
569/22.4
598/23.5
459/18.1
526/20.7
555/21.9
759/29.9
826/32.5
855/33.7
602/23.7
669/26.3
698/27.5
535/21.1
602/23.7
631/24.8
909/35.8
976/38.4
1005/39.6
769/30.3
798/31.4
609/24.0
676/26.6
705/27.8
1059/41.7
1126/44.3
1155/45.5
802/31.6
869/34.2
898/35.4
685/27.0
752/29.6
781/30.7
1209/47.6
1276/50.2
1305/51.4
902/35.5
969/38.1
DETECTION 1002/39.5 1069/42.1 ZONE
998/39.3
759/29.9
826/32.5
855/33.6
1359/53.5
1426/56.1
1455/57.3
1098/43.2
835/32.9
902/35.5
931/36.7
1509/59.4
1576/62.0
1605/63.2
1102/43.4
1169/46.0
1198/47.2
909/35.8
976/38.4
1005/39.6
1659/65.3
1726/68.0
1755/69.1
1269/50.0
1298/51.1
985/38.9
1052/41.4
1081/42.6
1809/71.2
1876/73.9
1905/75.0
1059/41.7
1126/44.3
1155/45.5
1135/44.7
1202/47.3
1231/48.5
1209/47.6
1276/50.2
1305/51.4
1285/50.6
1352/53.2
1381/54.4
1359/53.5
1426/56.1
1455/57.3
1435/56.5
1502/59.1
1531/60.3
1509/59.4
1576/62.0
1605/63.2
1585/62.4
1652/65.0
1681/66.2
1659/65.3
1726/68.0
1755/69.1
1735/68.3
1802/70.9
1831/72.1
1809/71.2
1876/73.9 MC4700-12
1905/75.0MC4700-14,-20,-30
RECEIVER 702/27.6
1202/47.3
LED INDICATORS
TRANSMITTER
LCM-XXX (NEMA BOX)
AVAILABLE DETECTION AVAILABLE DETECTION ZONE LENGTHS "A": ZONE LENGTHS "A":
Omron Scientific Technologies, Inc. For the Latest Information 100mm/3.94" INCREMENTS 150mm/5.91" INCREMENTS USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 On the Internet: www.sti.com or www.omron.ca mm 102.0 202.0 302.0 inches 4.02 7.95 11.89 mm 159.0 309.0 inches 6.26 12.17
D23
Page 5
MC4700, MCF4700 and MCJ4700
■ safety light curtains
D
Ordering for MC4700 Series
To order a MicroSafe MC4700 system, simply fill in the fields in the model number sequence given below. Each field is numbered and information on completing a specific field can be found in the sections which follow.
MC47LR
12 mm - 0.2 to 5 m (0.7 to 17 ft. ). For applications where the transmitter and receiver will be mounted less than 3 m (9.9 ft.) apart, please select the SR version above. 20 mm - 0.3 to 12 m (1 to 39 ft.). For applications where the transmitter and receiver will be mounted less than 7 m (23 ft.) apart, please select the SR version above.
specifications and dimensions on the ✎ For LCM Series Controller, see page D106 ____ - ____ - ____ - ____ - ____X - ____R - ____ 1 2 3 4 5 5 6
MC47SRS
Example: MC47SR-12-300-LCM1-10X-10R-RM1
Designator MC47SR
30 mm - 0.3 to 12 m (1 to 39 ft.). For applications where the transmitter and receiver will be mounted less than 7 m (23 ft.) apart, please select the SR version above. Low ESD MicroSafe System. Range based on minimum object resolution of the system. 12 mm - 0.2 to 3 m (0.7 to 10 ft.). For applications where the transmitter and receiver will be mounted less than 3 m (9.9 ft.) apart.
This MicroSafe system is short range has 12 mm (0.47 in.) minimum object resolution, a 300 mm (11.8 in.) protection height, an LCM1 controller, 10 m (33 ft.) transmitter and receiver cables, and an RM-1 relay output module. 1 Information required. Indicates operating range of the light curtain and if the MicroSafe system is manufactured to low ESD requirements. ESD systems are used where the build-up of an electrostatic charge on the light curtain and its subsequent discharge may harm the product being produced by the guarded machine (i.e. integrated circuits, disk drives, electronic components, etc.).
Range based on minimum object resolution of the system.
14 mm - 0.3 to 5 m (1 to 17 ft.). 20 mm - 0.3 to 7 m (1 to 23 ft.). For applications where the transmitter and receiver will be mounted less than 7 m (23 ft.) apart.
MC47LRS
30 mm - 0.3 to 7 m (1 to 23 ft.). For applications where the transmitter and receiver will be mounted less than 7 m (23 ft.) apart. Low ESD MicroSafe System. Range based on minimum object resolution of the system. 12 mm - 0.2 to 5 m (0.7 to 17 ft.). For applications where the transmitter and receiver will be mounted less than 3 m (9.9 ft.) apart, please select the SRS version above.
Description Range based on minimum object resolution of the system.
20 mm - 0.3 to 12 m (1 to 39 ft.). For applications where the transmitter and receiver will be mounted less than 7 m (23 ft.) apart, please select the SRS version above.
12 mm - 0.2 to 3 m (0.7 to 10 ft.). For applications where the transmitter and receiver will be mounted less than 3 m (9.9 ft.) apart.
30 mm - 0.3 to 12 m (1 to 39 ft.). For applications where the transmitter and receiver will be mounted less than 7 m (23 ft.) apart, please select the SRS version above.
14 mm - 0.3 to 5 m (1 to 17 ft.). 20 mm - 0.3 to 7 m (1 to 23 ft.). For applications where the transmitter and receiver will be mounted less than 7 m (23 ft.) apart. 30 mm - 0.3 to 7 m (1 to 23 ft.). For applications where the transmitter and receiver will be mounted less than 7 m (23 ft.) apart.
2 Information required. Represents the minimum object resolution of the light curtain in millimeters. Designators are described below. Designator
Minimum Object Resolution
12
12 mm (0.47 in.)
14
14 mm (0.55 in.)
20
20 mm (0.79 in.)
30
30 mm (1.18 in.)
A Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 D24
For the Latest Information On the Internet: www.sti.com or www.omron.ca
Go to the Engineering Guide For in-depth information on safety standards and use.
Page 6
MC4700, MCF4700 and MCJ4700
14 mm and 20 mm Minimum Object Resolution Systems
30 mm Minimum Object Resolution Systems
Designator # Beams
Protection Height
Designator # Beams
Protection Height
150
159 mm (6.3 in.)
150
7
159 mm (6.3 in.)
14
309 mm (12.2 in.)
14
225
21
235 mm (9.3 in.)
300
300
28
309 mm (12.2 in.)
450
21
459 mm (18.1 in.)
375
35
385 mm (15.2 in.)
600
28
609 mm (24.0 in.)
450
42
459 mm (18.1 in.)
750
35
759 mm (29.9 in.)
42
909 mm (35.8 in.)
525
49
535 mm (21.1 in.)
900
600
56
609 mm (24.0 in.)
1050
49
1059 mm (41.7 in.)
675
63
685 mm (27.0 in.)
1200
56
1209 mm (47.6 in.)
750
70
759 mm (29.9 in.)
1350
63
1359 mm (53.3 in.)
70
1509 mm (59.4 in.)
12 mm Minimum Object Resolution Systems
825
77
835 mm (32.9 in.)
1500
Designator # Beams
Protection Height
900
84
909 mm (35.8 in.)
1650
77
1659 mm (65.3 in.)
100
102 mm (4.0 in.)
975
91
985 mm (38.8 in.)
1800
84
1809 mm (71.2 in.)
98
1059 mm (41.7 in.)
16
200
32
202 mm (8.0 in.)
1050
300
48
302 mm (11.9 in.)
1125
105
1135 mm (44.7 in.)
400
64
402 mm (15.8 in.)
1200
112
1209 mm (47.6 in.)
500
80
502 mm (19.8 in.)
1275
119
1285 mm (50.6 in.)
126
1359 mm (53.3 in.)
600
96
602 mm (23.7 in.)
1350
700
112
702 mm (27.6 in.)
1425
133
1435 mm (56.5 in.)
800
128
802 mm (31.6 in.)
1500
140
1509 mm (59.4 in.)
900
144
902 mm (35.5 in.)
1575
147
1585 mm (62.4 in.)
154
1659 mm (65.3 in.)
1000
160
1002 mm (39.5 in.)
1650
1100
176
1102 mm (43.4 in.)
1725
161
1735 mm (68.3 in.)
1200
192
1202 mm (47.3 in.)
1800
168
1809 mm (71.2 in.)
D safety light curtains
3 Information required. Represents protective heights of the light curtain in millimeters. Protection heights available are a function of minimum object resolution. Designators are described below and divided into three sections, those for 12 mm resolutions, those for 14/20 mm and those for 30 mm resolutions.
4 Information required. Represents controller version. Designators and descriptions are given below. Designator
Description
LCM1
DIN-mount, IP20, solid-state safety output, 24 VDC
LCM2
DIN-mount, IP20, solid-state safety output, 24 VDC, DeviceNet interface
LCM3
DIN-mount, IP20, solid-state safety output, 24 VDC, non-CE-marked, multiple stored channel select patterns
LCM100
Metal enclosure, IP65, relay safety output, 100-230 VAC
LCM200
Metal enclosure, IP65, relay safety output, 100-230 VAC, DeviceNet interface
LCM300
Metal enclosure, IP65, relay safety output, 100-230 VAC, non-CE-marked, multiple stored channel select patterns
LCM110
Metal enclosure, IP65, relay safety output, 100-230 VAC, lid-mounted reset switch
LCM210
Metal enclosure, IP65, relay safety output, 100-230 VAC, lid-mounted reset switch, DeviceNet interface
LCM310
Metal enclosure, IP65, relay safety output, 100-230 VAC, lid-mounted reset switch, non-CE marked, multiple stored channel select patterns
LCM120
Metal enclosure, IP65, solid-state safety output, 24 VDC
LCM220
Metal enclosure, IP65, solid-state safety output, 24 VDC, DeviceNet interface (continued on next page)
Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
For the Latest Information On the Internet: www.sti.com or www.omron.ca
D25
Page 7
MC4700, MCF4700 and MCJ4700
■ safety light curtains
D
Ordering for MC4700 Series (continued)
LCM320
Metal enclosure, IP65, solid-state safety output, 24 VDC, non-CE-marked, multiple stored channel select patterns
LCM130
Metal enclosure, IP65, solid-state safety output, 24 VDC, lid-mounted reset switch
LCM230
Metal enclosure, IP65, solid-state safety output, 24 VDC, lid-mounted reset switch, DeviceNet interface
LCM330
Metal enclosure, IP65, solid-state safety output, 24 VDC, lid-mounted reset switch, non-CE marked, multiple stored channel select patterns
LCM140
Metal enclosure, IP65, relay safety output, 24 VDC
LCM240
Metal enclosure, IP65, relay safety output, 24 VDC, DeviceNet interface
LCM340
Metal enclosure, IP65, relay safety output, 24 VDC, non-CE-marked, multiple stored channel select patterns
LCM150
Metal enclosure, IP65, relay safety output, 24 VDC, lid-mounted reset switch
LCM250
Metal enclosure, IP65, relay safety output, 24 VDC, lid-mounted reset switch, DeviceNet interface
LCM350
Metal enclosure, IP65, relay safety output, 24 VDC, lid-mounted reset switch, non‑CE marked, multiple stored channel select patterns
Note: For more configurations with quick-disconnect connectors refer to the LCM controller section.
5 Information required. Represents transmitter (X) and receiver (R) cable length. Designators and descriptions are given below. Designator
Description
3
3 m (10 ft.)
10
10 m (33 ft.)
30
30 m (99 ft.)
6 Information optional. Indicate if you would like an Omron STI RM series resource module. Designator
Description
RM1
Include RM-1 resource module, force-guided relay output
RM3
Include RM-3 resource module, mute module
RM4
Include RM-4 resource module, allow for wiring up to four MC4700 systems
RMX
Include RM-X resource module
(Blank)
No RM series resource module information on Resource ✎ For Modules, see page D138 information on safety light ✎ For curtain accessories, see page D184
A Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 D26
For the Latest Information On the Internet: www.sti.com or www.omron.ca
Go to the Engineering Guide For in-depth information on safety standards and use.
Page 8
MC4700, MCF4700 and MCJ4700
Safety Standards and Precautions All models of the MicroSafe meet ANSI/RIA R15.06-1999, ANSI B11.19-2003. When used with mechanical power presses, OSHA industrial safety standards apply, as stated in 1910.217(c). For other applications, the machine guarding requirements found in section 1910.212 apply. The MicroSafe meets ANSI control reliability requirements for point-of-operation presence sensing devices. All controllers have CSA-CUS acceptance and are designed to meet UL508. MicroSafe systems employing LCM controllers (except those with the ability to store multiple channel select patterns) have been EC type examined to the requirements of category 4, EN 954-1 (type 4, IEC 61496). The MicroSafe should only be used on machinery that can consistently and immediately stop anywhere in its cycle or stroke. Never use a MicroSafe on a full revolution clutched power press or machine. If the light curtain does not protect all access to the point of operation, the unprotected access must be guarded by other appropriate devices such as mechanical guards. The purchaser, installer and employer have the responsibility to meet all local, state and federal government laws, rules, codes or regulations relating to the proper use, installation, operation and maintenance of this control and the guarded machine. See the Installation and Operation Manual for additional information. All application examples described are for illustration purposes only. Actual installations will differ from those indicated.
safety light curtains
Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D
For the Latest Information On the Internet: www.sti.com or www.omron.ca
D27
Page 9
MC4700, MCF4700 and MCJ4700
■
Dimensions for MCF4700 Series - mm/in. 16.7 X 6.8 DiA lg 0.66 0.27 SlOtS safety light curtains
D
25.9 [1.02] 40.5 [1.59]
"A" DectectiOn ZOne
"B" dimensions on the LCM Series ✎ For Controller, see page D106
0.56 [14.2]
"c" 255.4 [10.06] ShOWn
56.0 2.20 41.4 1.63 lASt Segment
"c" 270.9 [10.67] ShOWn
"A" DectectiOn ZOne
"B" miD Segment(S)
41.4 1.63 56.0 2.20
26.0 1.02
"A" DectectiOn ZOne
"B"
2.20 56.0 firSt Segment frOnt VieW
12.2 0.48
29.7 1.17 42.8 1.68
D28
27.3 c 1.08 l cl
SiDe VieW
A Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
"c"
30.3 1.19
41.4 O.D. 14.2 .56 DiA. 7.0 1.63 .28
28.0 1.10
31.0 1.22
44.3 1.74
For the Latest Information On the Internet: www.sti.com or www.omron.ca
Go to the Engineering Guide For in-depth information on safety standards and use.