Inner Boards
High-speed Counter Board CQM1H-CTB41
High-speed Counter Board
CQM1H-CTB41 The High-speed Counter Board is an Inner Board that counts up to 4 high-speed pulse inputs at up to 500 kHz, and can perform tasks according to the number of pulses counted. • Can count 4-axis high-speed pulses at up to 500 kHz. • Provides 4 external outputs on the Board. • Both linear and ring counting modes are supported. • The input can be a voltage input or an RS-422A line driver input. • Three input modes are available: differential phase mode, up/ down mode, and pulse + direction mode • The counters can be set to record the present values in decimal or hexadecimal.
Example System Configuration High-speed Counter Board
Incremental encoders
Specifications Item
Specifications
Name
High-speed Counter Board
Model number
CQM1H-CTB41
Applicable CPU Units
CQM1H-CPU51/61
Unit classification
CQM1H-series Inner Board
Mounting location/No. of Boards
Maximum of two Boards can be mounted simultaneously in slots 1 and 2.
Pulse inputs
4 inputs
External outputs
4 outputs
Current consumption (Supplied from Power Supply Unit)
5 V DC, 400 mA max.
Dimensions
25 × 110 × 107 mm (W × H × D)
Weight
90 g max.
Standard accessories
Plugs: XM2D-1501 (OMRON) x 2 Hoods: XM2S-1511 (OMRON) x 2
35
Page 33
Inner Boards
High-speed Counter Board CQM1H-CTB41
Pulse Inputs (High-speed Counters) Pulse Input Function Item
Specifications
Number of counters
4 counters (4 ports)
Input modes (Set in the PLC Setup.)
Differential Phase Inputs
Input method
Two single-phase inputs Switching between inputs using phase difference multiples of 1x, 2x, or 4x. (Set in the PLC Setup.)
Single-phase pulse and direction inputs
Count frequency (Set for each port in the PLC Setup.)
25 kHz (default) or 250 kHz 50 kHz (default) or 500 kHz
50 kHz (default) or 500 kHz
Count values
Linear counting:–8388608 to 8388607 BCD, F8000000 to 07FFFFFF Hex Ring counting:00000000 to 08388607 BCD, 00000000 to 07FFFFFF Hex
Control method
Up/Down Pulse Inputs
Pulse/Direction Inputs
Target value comparison
Up to 48 target values and external/internal output bit patterns registered.
Range comparison
Up to 16 upper limits, lower limits, and external/internal output bit patterns registered.
Pulse Input Specifications Item
Specifications
Number of pulse inputs
4 inputs (Ports 1 to 4 = High-speed counters 1 to 4)
Signals
Encoder inputs A and B; pulse input Z
Input voltage
Switched by means of input voltage switch on the Board (Specified separately for phases A, B, and Z.) 24 V DC±10%
RS-422A line driver (AM26LS31 or equivalent)
Phase A and B
Phase Z
Phase A and B
Phase Z
Input current
5 mA typical
8 mA typical
10 mA typical
13 mA typical
ON voltage
19.6 V DC min.
18.6 V DC min.
---
---
OFF voltage
4.0 V DC min.
4.0 V DC min.
---
---
External Output Specifications Item
Specifications
Number of external outputs
4 transistor outputs (The four outputs are set together as sinking or sourcing outputs in the PLC Setup.)
Function
The target comparison or range comparison results of high-speed counters 1 to 4 output four user-defined 4-bit external bit patterns (bits 08 to 11 of either IR 208 to IR 211 or IR 240 to IR 243). An OR is taken of corresponding bits in these four bit patterns, and the result is output on external outputs 1 to 4.
External power supply
5 to 24 V DC±10%
Switching capacity
16 mA/4.5 V DC to 80 mA/26.4 V
Leakage current
0.1 mA max.
Residual voltage
0.8 V max.
Response time
ON response: 0.1 ms max.; OFF response: 0.4 ms max.
36
Page 34
Inner Boards
Pulse I/O Board CQM1H-PLB21
Pulse I/O Board
CQM1H-PLB21 The Pulse I/O Board is an Inner Board that supports two pulse inputs and two pulse outputs.
Pulse Inputs • The two pulse inputs to high-speed counters count pulses at up to 50 kHz (signal phase) or 25 kHz (differential phase). Interrupt can be created based on the counter present values (PV).
Interrupts The Board can execute an interrupt subroutine when the counter PV matches a specified target value (target value comparison) or falls within a specified comparison range (range comparison.)
Pulse Outputs 1 and 2 Two 10 Hz to 50 kHz pulses can be output. Both fixed and variable duty factors can be used.
• The fixed duty factor can be used to change the output frequency (accelerate or decelerate) from 10 Hz to 50 kHz smoothly. • The variable duty factor performs using a duty factor ranging from 1% to 99%. Variable duty factor pulses can be used for applications such as time-proportional control.
Example System Configuration Pulse I/O Board
Pulse input 2
Incremental encoder
Pulse output 1
Pulse output 2 Motor driver
Motor driver
Motor
Motor
Pulse input 1
Incremental encoder
37
Page 35
Inner Boards
Pulse I/O Board CQM1H-PLB21
Specifications Item
Specifications
Name
Pulse I/O Board
Model number
CQM1H-PLB21
Applicable CPU Units
CQM1H-CPU51/61
Unit classification
CQM1H-series Inner Board
Mounting locations/No. of Boards
One in Inner Board slot 2 (right slot)
Pulse inputs
2 inputs
Pulse outputs
2 outputs
Current consumption (Supplied from Power Supply Unit)
5 V DC, 160 mA max.
Dimensions
25 × 110 × 107 mm (W × H × D)
Weight
90 g max.
Standard accessories
Two XM2D-1501 Plugs and two XM2S-1511 Hoods (OMRON)
■ Pulse Input (High-speed Counter) Specifications Pulse Input Function Item
Specifications
Number of counters
2 counters (ports)
Input Modes (Set for each port in the PLC Differential phase input Setup.)
Pulse/Direction input
Up/Down pulse input
Input method
Phase difference multiple of 4 (Fixed)
Single-phase pulse + direction
Single-phase input x 2
Count frequency
25 kHz
50 kHz
50 kHz
Count values
Linear counting: –8388608 to 8388607 BCD Ring counting: 00000000 to 00064999 BCD
Control method
Target value comparison
Register up to 48 target values and interrupt subroutine numbers.
Range comparison
Register up to 8 upper limits, lower limits, and interrupt subroutine numbers.
Pulse Input Specifications Item Number of pulse inputs
Specifications 2 inputs (Ports 1 and 2 = Pulses 1 and 2)
Signal names
Encoder input A, encoder input B, pulse input Z
Input voltage
Switched by means of connector pins (Can be specified separately for phases A, B, and Z.) 12 V DC±10%
Input current
24 V DC±10%
Phases A and B
Phase Z
Phases A and B
Phase Z
5 mA typical
12 mA typical
5 mA typical
12 mA typical
ON voltage
10.2 V DC min.
20.4 V DC min.
OFF voltage
3.0 V DC min.
4.0 V DC min.
38
Page 36
Inner Boards
Pulse I/O Board CQM1H-PLB21
■ Pulse Output Specifications Pulse Output Function Pulse output function is determined by the output method, as indicated below. Item
Fixed duty factor Without trapezoidal acceleration/ deceleration
Variable duty factor
With trapezoidal acceleration/deceleration Same acceleration/ deceleration rates
Separate acceleration/ deceleration rates
Instruction
PULS(65)/SPED(64)
PLS2(––)
PULS(65)/ ACC(––)
PWM(––)
Output frequency
10 Hz to 50 kHz (10 Hz to 20 kHz for stepping motor)
0 Hz to 50 kHz
100 Hz to 50 kHz
91.6 Hz, 1.5 kHz, 5.9 kHz
Output frequency pitch
1 or 10 Hz
10 Hz
Duty factor
50% fixed
1 to 99%
Number of output pulses
1 to 16,777,215
---
Acceleration/ deceleration rate
---
---
10 Hz to 2 kHz (every 4.08 ms)
---
Output Specifications Item Number of pulse outputs
Specifications 2 outputs (Ports 1 and 2 = Pulse outputs 1 and 2)
Signal names
CW and CCW pulse output
Max. output frequency
50 kHz (20 kHz with stepping motor connected.)
External power supply
5 V DC±5% 30 mA min.; 24 V DC +10%/–15% 30 mA min.
Max. switching capacity
NPN open collector, 30 mA/5 to 24 V DC±10%
Min. switching capacity
NPN open collector, 7 mA/5 to 24 V DC±10%
Leakage current
0.1 mA max.
Residual voltage
0.4 V max.
39