Page 27

5

Handling the device

5.1

Cleaning the device

The PL3000 casing and keyboard should be cleaned with clean, moist, non-abrasive, lint-free cloth. Note that intensive rubbing of the soft rubber part of the top-cover and the back of battery pack cover may harm the rubber coating. The PL3000 display window and the imager window may be cleaned with a clean, non-abrasive, lint-free cloth. NOTE: The use alcohol or detergents may harm the casing and is therefore not recommended. Any moisture inside the battery compartment or in the headset jack may be harmful for the device. 5.2

Using the keyboard

Nordic ID recommends the use of the keyboard. The user friendly keyboard of the PL3000 has 29 large-size keys which are easily operated with a thumb. The keyboard has also a backlight and individual key light activation which will guide the user if needed. 5.3

Using stylus and touch screen

Use the touch screen only with a stylus supplied by Nordic ID, do not use extensive force since it may damage the display’s surface. To prevent loosing the stylus, it can be connected to the PL3000 with a string.

Fig.28 Using stylus

©2005 Nordic ID Oy Nordic ID PL3000 user manual, v. 2.4, March 2006

27

Page 28

5.4

Resetting the device

5.4.1

Software resets

A short press of the power key can start the software-reset process. A shutdown application window will appear on the display of the PL3000. In the shutdown selection window there are: • • • •

Suspend Warm reset Cold reset and Windows CE reload

Select the type of reset required. The description of the reset type is shown in dialogue box of the shutdown window. In the suspend mode the display is switched off. When restarted Windows will continue from where it was. Use suspend mode when you want to save the battery life but wish to continue the use of the device from where you were. Suspend should be used in normal use.

Fig.29 Suspend window

©2005 Nordic ID Oy Nordic ID PL3000 user manual, v. 2.4, March 2006

28

Page 29

In a warm reset the memory and windows registry remains, but all unsaved data will be lost. The installation of software may require a warm reset of the device. In a cold reset the RAM will be cleared and unsaved registry modifications will be lost. Use the Cold reset when you want to remove installed software. In the Reload Windows CE RAM memory will be reloaded from FLASH memory. All unsaved data and registry modifications will be lost. Reloading Windows CE is mostly used by software developers when a device image is updated. Reset with reset switch The reset switch is located on the left side inside the battery compartment. By pressing the reset switch the device starts the reloading of Windows CE. Unnecessary reset with the reset switch is not recommended.

Reset switch

Fig.30 Reset switch of PL3000

Starting the device after reset The device remains switched off after a reset and starts with loading Windows when the power key is pressed again and the battery cover is in place.

©2005 Nordic ID Oy Nordic ID PL3000 user manual, v. 2.4, March 2006

29

Page 30

5.4.2

Managing battery power

The battery power and power save functionality can be controlled from the controlpanel’s Power properties. See the chapter 6.5.16. for details. To save the battery power, do not use the keyboard backlight display if not necessary and suspend the device when not in use. With the Pistol Grip accessory a second battery pack can be taken into use to prolong the battery life. When longer than normal operating time is required the use of spare batteries is recommended. The PL3000 requires a constant supply of power in order to be operational.

Fig.31 Power properties windows

5.4.3

Changing the battery pack

When the power of the PL3000 battery has decreased to 5% of the full charge, a pop-up window will appear on the display of the device, notifying the user that the battery level is low. This indicates that the device should be placed immediately in the charger.

©2005 Nordic ID Oy Nordic ID PL3000 user manual, v. 2.4, March 2006

30

Page 31

After this indication you should save all unsaved data and settings, and then change the battery pack or charge the battery. If at any point the power level drops below the final threshold value (2% of full charge) the PL3000 enters into suspend mode. When the battery cover is opened the PL3000 performs a file system backup and suspends Windows CE. The memory with all settings and files is maintained with the backup battery for about 2 hours. During this period the main battery should be installed again. The backup battery is fully charged after every 20 hours of use. The battery is located in the compartment inside the PL3000 handle. Open the compartment by loosing the screw on the bottom of the device and lifting off the back cover. Place the bottom of the battery to the bottom of the battery compartment. Press it against the support foam so that battery connectors face the connectors in the device. Push the top end of the battery into the compartment If you are using a hand strap, note that it is easier to slip it under the holding bar when battery cover is not closed. Close the battery cover and tighten the screw. If the battery cover is not properly closed the PL3000 IPrating may be lost. 5.4.4

File System Backup

The File System Backup application allows you to backup all files in the RAM file system of the PL3000 to FLASH memory. At the same time as the backup is made, a monitor file is created in the Windows folder. Every time the device boots up the File System Backup verifies that the file is present. If not, it means either that there has been a power failure that has led to the erasing of the RAM or that a hard reset has been made. In both cases File System Backup proceeds to restore the backed up files to their correct place in RAM. Using file backup system prevents losing programs or data from RAM memory even when the PL3000’s battery is removed. Choose “File System Backup” from the Nordic ID folder under programs in the start-up menu. Choose “Backup RAM Files” The device shows the backup progress on the display.

©2005 Nordic ID Oy Nordic ID PL3000 user manual, v. 2.4, March 2006

31

Page 32

Fig.32 File System Backup window

When the backup is complete, the text “Backup Complete, files copied to \FLASH\RAMBackup” appears on the display. Close the File System Backup by selecting “Close”. Before closing the file is compressed, this takes a few seconds. The backup copies of the RAM files are contained in a single file in the FLASH folder: /FLASH/RamBackup/RamBackup.pak 5.4.5

Saving the registry

Saving the registry saves the PL3000’s settings permanently. Save the Windows registry by choosing the program “RegBackup” from the Nordic ID folder under programs in the start-up menu. Select yes for saving the registry. When saving the registry, the dialogue window in figure 33 appears on the display. Answer “start” and close the window.

©2005 Nordic ID Oy Nordic ID PL3000 user manual, v. 2.4, March 2006

32

Page 33

Fig.33 Saving registry window

5.4.6

Setting time and date

Double click the time icon on the bar menu. Set the date and time from the display and select “Apply”. Start using the settings by pressing the OK key on the keyboard.

©2005 Nordic ID Oy Nordic ID PL3000 user manual, v. 2.4, March 2006

33

Page 34

5.4.7

Reading codes

The optimum reading distance varies with the barcode type and size. Typically the optimum distance is about 15 cm. With LED-sighting device a good distance is when the green aiming light covers the code area from side to side. If the code is not read check the reader settings from your system integrator. Reading is fastest when the code is read at right angle to the reader. Start code reading with scan button.

Fig.34 Reading codes

5.4.8

Utilising virtual keyboard

Open the virtual keyboard menu from the control bar’s keyboard icon. Select Keyboard from the menu. The keyboard appears at the bottom of the display. The virtual keyboard is displayed in the figure 35. You can move the keyboard by grabbing it from the upper bar and dragging it onto the screen.

©2005 Nordic ID Oy Nordic ID PL3000 user manual, v. 2.4, March 2006

34

Page 35

Fig.35 Virtual keyboard

Special characters can be chosen by selecting the SHIFT key. Scandic letters and other special characters can be used by selecting the [áü] key. You can close the virtual keyboard by opening the keyboard menu from the control bar and by selecting “Hide input panel”.

©2005 Nordic ID Oy Nordic ID PL3000 user manual, v. 2.4, March 2006

35