Page 86

Appendix E Creating Cisco WLAN connection Start the Aironet Client Utility (ACU) from the start-up menu. Programs are in the Cisco folder. Create a profile and edit the settings according to your network. See the chapter Control panel, ACU to read more about Aironet Client Utility. To ensure that there is sufficient signal in the WLAN network you should use the site survey tool of the ACU. After creating the profile and settings, connect to the network using the Wireless Login Module under Startup menu within programs within Cisco. Exemplary Ad-Hoc network installation Add a network by using the Aironet Client Utility. Write the SSID code of the network you have selected. Choose the Infrastructure Mode value: No Confirm the setting by clicking OK Select active profile: AdHoc and confirm the setting by clicking OK After setting set fixed IP addresses to the PL3000 and the PC an Adhoc network is created. Set the IP address of the PL3000 from the Start menu/settings/Dial up Connections/Cisco Properties and specify an IP address The IP Address, Subnet mask, Default Gateway Primary DNS and Secondary DNS addresses must be same as for the PC. Confirm the settings by clicking OK

©2005 Nordic ID Oy Nordic ID PL3000 user manual, v. 2.4, March 2006

86

Page 87

Appendix F Creating Option GPRS connection When the GPRS card is installed the device recognises the card when the PL3000 is turned on. The text “Pin Driver, registering to network” appears on the display” to take the GPRS card into use. From the Startup menu select network and dial up connections. Choose the GPRS, connection, select the modem and choose Globetrotter and click “OK” Set the API to Internet from the “API” software in the control panel. When starting the browser or otherwise establishing the connection, a dial-up window appears in the display. If needed the password and username are supplied by the network operator. Depending on the actual SIM card and network provider you may need to manually change the settings. For the correct settings consult your network provider. If the automatic IP settings are not supported you may need to set the DNS server IP address manually. Settings/network and dial up connections, GPRS connections, properties, TCP/IP settings/name servers primary and secondary DNS. Click “OK” to save the settings

©2005 Nordic ID Oy Nordic ID PL3000 user manual, v. 2.4, March 2006

87

Page 88

Appendix G Application development Microsoft Windows CE.NET 4.2 Windows CE .NET 4.2 is a robust operating system for the professional PDT and embedded device market. The Operating System is highly configurable and customisable and includes a great deal of the features found in desktop Windows computers today. Windows CE .NET 4.2 and Windows Mobile 2003 are running the same version of the kernel, but as with previous versions, they are not compatible. The reason for this is the user interface, which differs to such a degree that compatibility is not possible. Program compatibility When looking for existing programs that will run on your PL3000, there are three things to consider. First; the target Operating System must be Windows CE .NET or one of its predecessors. If you use a program compiled for a predecessor, such as H-PC 3000, you will probably also need the dynamic link libraries it is dependent on. The one typically required is MFCCE300.DLL or MFCCE211.DLL. The PL3000 has the file MFCCE420.DLL preinstalled which is the correct one for Windows CE .NET 4.2. The second thing you need to take into account is the processor architecture. The brand name or manufacturer of the processor is not important. If the programs are wanted to run on the PL3000, they need to be compiled for the PL3000 processor. The last thing to remember is the display orientation and size. Almost all programs and drivers that work for the PL3000 have dialogues made for a PL3000 screen. If the display shape or size does not fit the PL3000 and a change cannot be made, use scroll bars and display rotating software. SDK & Application types The Software Development Kit (SDK) for the PL3000 is available by request. To register and order the SDK package please see the support section in Nordic ID web page www.nordicid.com or contact Nordic ID directly. The SDK is necessary for all solutions where a custom application will be programmed for and installed on the PL3000. For solutions using technologies such as terminal emulation or Internet Explorer you will not require the SDK. These types of applications require no development on the PL3000 unit as the application is built on the server. For terminal emulation Nordic ID can recommend third party terminal emulation software which has been tested with the PL3000. To develop software that will run on the PL3000, you will require:

©2005 Nordic ID Oy Nordic ID PL3000 user manual, v. 2.4, March 2006

88

Page 89

C++ Application development • • • • •

ActiveSync 3.5 or later installed on your host PC. eMbedded Visual C++ 4.0 The PL3000 Windows CE 4.2 SDK ht.dll version 2.1 present on your host PC. Additionally the general Windows CE .NET 4.2 SDK is good to have installed.

All of these tools are free and available from the Nordic ID SDK site, except the eMbedded Visual C++ 4.0 application. It is available free of charge from Microsoft. .NET Compact framework application development • • • •

ActiveSync 3.7 or later installed on your host PC. Microsoft Visual Studio .NET 2003 (or later) with the Compact Framework package installed The PL3000 Windows CE 4.2 SDK installed. ht_NET.dll version 2.1 present on your host PC.

HTML + J Script / VBScript Application development As this type of solution uses the Internet Explorer 6.0 application on the PL3000, no third party development tools are explicitly required. Some PL3000 specific hardware features are only available by calling a COM component trough a client side script in your solution. This COM component is documented in the Nordic ID SDK pages. You do not need to download and install the SDK for this type of solution.

©2005 Nordic ID Oy Nordic ID PL3000 user manual, v. 2.4, March 2006

89

Page 90

Appendix H Configuring the Linksys WCF54G –card This appendix describes the configuration of the wireless network with Linksys WCF54G –network adapter. Glossary of term WEP

The first security standard used in wireless networks to encrypt the wireless network traffic.

WPA

Wi-Fi Protected Access. An improved security standard for wireless networks that provides stronger data protection and network access control. It provides stronger data protection by using encryption, access controls and user authentication (not included in WEP). WPA utilizes 128-bit encryption keys and dynamic session keys to ensure the wireless network’s privacy and security.

PSK

A mechanism in Wi-Fi Protected Access (WPA) that allows the use of manually entered keys or passwords to initiate WPA security. The PSK is entered on the access point or wireless gateway and each device that is on the Wi-Fi network. The password also initiates the encryption process which, in WPA is Temporal Key Integrity Protocol (TKIP).

EAP

Extensible Authentication Protocol. A protocol that provides an authentication Framework for both wireless and wired Ethernet enterprise networks.

Required information from the network administrator: -

Network SSID (name) Type of network (AdHock or Network) Encryption used Authentication method used Network key (PSK)

Connecting to the wireless network Before configuring the wireless network settings define the IP-addresses and Name servers from the “Settings – Network and Dial-up connections” –menu. The Linksys -card should automatically create the default IP-setting file named “WLAG46F1”. By default the IP-addresses and nameservers are configured to be obtained by DHCP. Modify the setting by tapping that file and typing the IP-addresses and Name servers if needed. By default the program always pops up when new network(s) is detected, this can be disabled by unchecking the “Notify when new networks available” checkbox. If not, open the application by double tapping the Network connections –tray icon (see picture) and select the Wireless Information –tab.

©2005 Nordic ID Oy Nordic ID PL3000 user manual, v. 2.4, March 2006

90

Page 91

Fig: Detected networks in range. NID_ Fig: Wireless properties -window. Enter Fig: Network monitor -window. WLAN is being connected. Authorithe network settings here. sation process in progress.

Networks within reach are listed below Add New… -selection. Note: If the network is configured as not visible, it cannot be seen in this window. Open the network configuration window by tapping the desired network or Add New…-selection in the listbox . Fill the wireless properties with the information provided by your network administrator. Save the settings and close the window by tapping the OK-box at the top of the window. After configuring the wireless properties, choose the network to be connected from the listbox and tap the connect -button. The PL3000 tries to connect the selected network and indicates the connection status at the window below the Available networks –listbox. Also the signal strength of the selected network is shown. Network Monitor window The Network monitor application can be opened from Programs – WCF54G Wireless Network Monitor. This application shows the status of the current network connection, tools for network management and troubleshooting and controls for wlan radio power.

©2005 Nordic ID Oy Nordic ID PL3000 user manual, v. 2.4, March 2006

91