The text of a manual · part 5 of 21
6910 Integrated and 6910 Telnet Gateway/Access Points User's Guide: Section 2: 6910 Integrated Gateway/Access Point, pages 23 to 30
Pages 23 to 30 of 168, from 6910 Integrated and 6910 Telnet Gateway/Access Points User's Guide
The original document is the PDF (579 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Norand 6910 and Intermec 6910
Page 23
SECTION 2
"
6910 Integrated Gateway/Access Point
3. Do not press a key within 5 seconds of the first ROM message. Wait until the FLASH (third) message displays. The FLASH message displays only at the default setting of 9600 E71 or at the speed you set in FLASH mode through the configuration menus. If you do not see the FLASH message, you have selected the wrong baud rate in the serial communications program. 4. After the FLASH message displays, enter this command to put the gateway/access point’s DIAG (HOST) port into configuration mode: CMT27,2 Note the following: Type CMT in uppercase and do not enter spaces between any characters in the command. " There is a 1 second timeout period between characters. If you wait more than 1 second to type the next character, the gateway/access point will not recognize the command. " If you type the wrong character you cannot use the backspace key to correct it. You must either wait 1 second or press [Enter] before trying again.
"
Accessing the ROM Command Monitor " NOTE:
If you are replacing an RM2216, RM3216, or RC3250 Controller, see “Notice for UHF Controllers” on page 2-10.
6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide
2-9
Page 24
SECTION 2
"
6910 Integrated Gateway/Access Point
1. Set the terminal emulation parameters. If you are configuring this device for the first time, set the parameters to the default settings for ROM mode: 9600, N81, full duplex If you have already changed the default settings, set the parameters to those you set in ROM mode through the ROM command monitor. 2. Plug the gateway/access point into the outlet. These messages appear (the first two are ROM power-up messages and the third is FLASH): Press any key within 5 seconds to enter ROM command monitor Executing file IGAP6910.BIN from segment <segment number> POWER UPMUX V9.22,16 (this is the default host port message)
3. Press any key within 5 seconds of the first ROM message. The two ROM messages display at the default setting of 9600 N81 or at the speed you set in ROM mode. Note that if the gateway/access point is in Power-Up Quiet mode (versus Power-up Normal mode, the default setting), the ROM messages do not display. 4. Refer to Section 5, “Configuration,” in the 6710 Access Point User’s Guide for more information about the ROM command monitor, PQ mode, and PN mode.
Notice for UHF Controllers If you are replacing an RM2216, RM3216, or RC3250 Controller with the integrated gateway/access point, applications that were running on the controller can become confused when the ROM power-up messages appear on the network because the host is expecting standard controller power-up messages.
2-10
6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide
Page 25
SECTION 2
"
6910 Integrated Gateway/Access Point
Do one of the following to suppress the ROM power-up messages: Access the ROM command monitor and turn Power-up Quiet mode to ON. Reboot the gateway/access point. " Plug the gateway/access point into the outlet without the host connected to the gateway/access points’ DIAG (HOST) port. After both ROM power-up messages display, connect the host to the gateway/access point. "
Gateway Default and Site Settings The gateway/access point is factory configured with the default gateway settings listed in the following chart. You may need to change the defaults to match the way your system is set up. You can record your site’s settings in the table for reference. Gateway Option
Default
Name
HOST
Gateway.Compression
Disabled
Host Type
Async
Site Setting
[Async Parms] Baud Rate
9600
Stop Bits
1
Parity
Even
Data Bits
7
Host Timeout
0
Address Type
Old
Enhanced R Polling Disabled Multiple Buffering
Disabled
6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide
2-11
Page 26
SECTION 2
"
6910 Integrated Gateway/Access Point
Gateway Options Options for the gateway application are as follows: Name Gateway.Compression Host Type [Async Parms]
" NOTE:
“HOST” <Disabled> <Async>
[Async Parms] appears only if Host Type is set to Async.
Name The Name option is an arbitrary name that identifies this gateway/access point. Wireless stations use the arbitrary name to connect to this gateway/access point. Note that Name is not your application’s host server name. The setting for Name must match the host name specified for each wireless station communicating with the host through this gateway/access point. The names must match so that the wireless stations can communicate with the host. Refer to the wireless station’s user’s guide for more information about specifying host names. The setting for Name is case sensitive. For example, if the host name specified for the wireless stations is typed in all uppercase, the name for the gateway/access point must also be typed in all uppercase. Figure 2-5 shows an example of how host name HOST1 is set on a gateway/access point and wireless station.
2-12
6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide
Page 27
SECTION 2
"
6910 Integrated Gateway/Access Point
6910 Integrated Gateway/Access Point Name: HOST1 Host type: Async
Host
Ethernet (Distribution) LAN
6710 Access Point
RT1100 Radio Terminal Name: HOST1 Firmware: Native
Figure 2-5 Host Names
The prompt for Name is: Range is: 16 chars
Type 16 or fewer alphanumeric characters for the name. The program inserts quotation marks around your entry.
6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide
2-13
Page 28
SECTION 2
"
6910 Integrated Gateway/Access Point
Gateway.Compression Gateway.Compression uses a general data compression algorithm to reduce the size of data being sent to a wireless station. Settings are: Enabled Disabled
Setting
Description
Enabled
Compresses most outbound data from the gateway/access point to the wireless stations. Inbound data sent from the station is not compressed. Compression takes place on a client-by-client basis as allowed by each client. Does not compress data.
Disabled (default)
On most systems, compression reduces the RF (radio frequency) load by compressing most of the outbound data from the host to the wireless station. It is strongly recommended that you enable Gateway.Compression. Compression does not significantly increase wireless station counts or supported transaction rates. It does improve response time consistency in applications where the same data or screens are frequently repeated. The effectiveness of compression varies with the size and number of unique screens. While compression may reduce the amount of data being sent through the RF system, it increases the gateway/access point’s processing load. Therefore, it may be beneficial to disable compression for some systems.
2-14
6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide
Page 29
SECTION 2
"
6910 Integrated Gateway/Access Point
Host Type Use Host Type to select the type of communications the host uses: Async None
Setting
Description
Async (default)
Indicates that one host connects through RS-232 and uses a proprietary protocol to multiplex all wireless stations. Use Async for NORAND Native communications and ADK. Disables gateway/access point functionality. The device functions only as a 6710 Access Point.
None
[Async Parms] Options for [Async Parms] configure RS-232 parameters and the asynchronous multiplexing protocol: Baud Rate Stop Bits Parity Data Bits Host Timeout Address Type Enhanced R Polling Multiple Buffering
<9600> <1> <Even> <7> 0 <Old> <Disabled> <Disabled>
6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide
2-15
Page 30
SECTION 2
"
6910 Integrated Gateway/Access Point
Baud Rate Baud Rate sets the serial communication speed in bits per second. Settings are: 300 1200 2400 4800 9600 19200 38400
The default is 9600. To avoid confusion, the Baud Rate setting should match the serial baud rate setting for the ROM command monitor. Different baud rate settings, however, do not affect gateway/access point operation. Refer to Section 5, “Software Download,” in the 6710 Access Point User’s Guide for more information about the serial baud rate setting for the ROM command monitor. Stop Bits Stop Bits sets the number of stop bits to be sent with each character: 1 2
The default is 1. Parity Parity sets the data parity:
2-16
6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide