Page 15

Section 2

6910 Integrated Gateway/Access Point "

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

Features and Functional Overview " NOTE:

Refer to Section 2, “Features and Function Overview,” in the 6710 Access Point User’s Guide for information about access point bridging functionality, configuration, network management, and hardware components.

The 6910 Integrated Gateway/Access Point combines the functionality of a gateway device and the 6710 Access Point to support the NORANDR Native communications type for small installations. As an optional wired bridge, the gateway/access point bridges frames between the wired Ethernet LAN and wireless stations on the radio network. An optional function is to serve as the connection point for several types of wireless stations, which include terminal emulation stations and PC-compatible computers. When configured with host options, the gateway/access point picks up data frames from the wireless stations. It translates the frames into the appropriate host protocol and sends the data to the host through its DIAG (HOST) port. This section describes how to set host and gateway configuration options. For more information about the Native communications type, refer to the Native Terminal Emulation Asynchronous Programmer’s Reference Guide (P/N 977-047-038). 6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide

2-1

Page 16

SECTION 2

"

6910 Integrated Gateway/Access Point

Wireless Station Support The gateway/access point with the WLIF or 900 MHz radio option supports these wireless stations: "

RT1100, RT1700, and RT5900 series radio terminals

PEN*KEYR 6400, 6500, and 6550 Computers The S-UHF radio supports these wireless stations: "

" "

"

RT5921 Mobile Mount Radio Terminal TM1100 Radio Terminal with RM31 (integrated scanning) and RM11 radio modules TM1700 Radio Terminal with RM31 (integrated scanning) and RM11 radio modules

Configuration of individual radio options is discussed in the 6710 Access Point User’s Guide.

Host Connectivity Figure 2-1 is a sample configuration with host connectivity.

Host

RT1100 Radio Terminal

6910 Integrated Gateway/ Access Point

PEN*KEY 6400 Computer

Figure 2-1 Sample Host Connectivity Configuration

2-2

6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide

Page 17

SECTION 2

"

6910 Integrated Gateway/Access Point

Ethernet Connectivity Figure 2-2 is a sample configuration with Ethernet connectivity. The figure also shows 6710 Access Points, which can provide additional coverage and wireless links to secondary Ethernet LANs.

LAN Server

Ethernet (Distribution) LAN

6910 Integrated Gateway/Access Point

6710 Access Point

6710 Access Point (Designated Bridge)

RT1100 Radio Terminal

PEN*KEY 6400 Computer

Secondary Ethernet LAN

Desktop

Figure 2-2 Sample Ethernet Connectivity Configuration

Configuration of secondary Ethernet LANs and wireless links is discussed in the 6710 Access Point User’s Guide. 6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide

2-3

Page 18

SECTION 2

"

6910 Integrated Gateway/Access Point

Installation Refer to Section 3, “Installation,” in the 6710 Access Point User’s Guide for information about the following: " Preparing for the installation. " Collecting the proper Ethernet components and communication equipment. Note that the gateway/access point and 6710 Access Point use different DIAG port cables. See “Local DIAG (HOST) Port Access” below for the appropriate cables for the gateway/access point. " Finding the best location. " Mounting the access point. " Connecting the access point to Ethernet media. " Installing WLIF, 900 MHz, and S-UHF PC cards. " Applying power to the access point.

Local DIAG (HOST) Port Access The gateway/access point’s DIAG (HOST) port is a 9-pin D-sub communication port that communicates at RS-232 levels. Use this port to configure the gateway/access point, download new software, retrieve statistics, and connect to the host computer. The following chart lists the cables that connect a PC to the gateway/access point’s DIAG (HOST) port. Cable pin-outs start on page 2-21. PC Port

Cable P/N

9-pin male 25-pin male

226-208-00X* 226-208-00X* plus the 9-pin to 25-pin adapter provided with the cable 25-pin female 226-243-00X* * -001 = 10 feet, -002 = 25 feet, -003 = 50 feet

2-4

6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide

Page 19

SECTION 2

"

6910 Integrated Gateway/Access Point

Connecting to the Host To connect the gateway/access point to the host, see Figure 2-3 and the procedure following it.

10 BASE 2

10 BASE T

AUI

DIAG

AC INPUT 110/220 VAC Host cable (page 2-4 lists cables)

Figure 2-3 Host Connection

1. Plug the 9-pin male connector on the host cable into the DIAG (HOST) port. 2. Plug the connector on the other end of the cable into the designated communications port on the host.

6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide

2-5

Page 20

SECTION 2

"

6910 Integrated Gateway/Access Point

Configuration The following pages describe how to create a local DIAG (HOST) port session with the gateway/access point and access FLASH and ROM. The pages also describe host and gateway options and how to configure them. Refer to Section 4, “Configuration,” in the 6710 Access Point User’s Guide for information about how to do the following: Create a Telnet session and Web browser session. " Set up TCP/IP, bridge, and security options. However, see page 2-19 in this section for specific gateway/access point configuration guidelines. Refer to Section 5, “Software Download,” in the 6710 Access Point User’s Guide for information about the software download process, including the file system structure, File Menu commands, and the ROM command monitor. When referring to Section 5, substitute USTART29.BIN (the FLASH file for the 6710 Access Point) with IGAP6910.BIN (the FLASH file for the integrated gateway/access point). "

Creating a Local DIAG Port Session DIAG port functionality is shared on the gateway/access point as follows: When the gateway/access point initially powers up, its DIAG port functions as the ROM command interpreter. ROM DIAG port default settings are 9600, N81. " As the device continues to power up, the DIAG port becomes a host port with default settings of 9600, E71. The functional DIAG port and host port settings are independent and must be configured separately. "

2-6

6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide

Page 21

SECTION 2

"

6910 Integrated Gateway/Access Point

You establish a local DIAG (HOST) port session with the gateway/access point through a VT100 terminal emulation program, such as PROCOMM PLUS installed on a PC. When the program is running you issue host command “CMT27,2” to put the DIAG (HOST) port into configuration mode. When you exit the configuration menus, the port automatically switches into host mode. To create a local session, see Figure 2-4 and the procedure following it. You should carefully review the procedure first to become familiar with the process. 1

2

3

10BASE2

10BASET

AUI

DIAG

AC INPUT 110/220 VAC

1. PC with terminal emulation program 2. Cable: P/N 226-208-00X for a 9-pin male PC COM port (a 9-pin to 25-pin adapter is required for a 25-pin port) or Cable: P/N 226-243-00X for a 25-pin female PC COM port 3. 6910 Integrated Gateway/Access Point DIAG (HOST) port

Figure 2-4 Local DIAG (HOST) Port Session

6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide

2-7

Page 22

SECTION 2

"

6910 Integrated Gateway/Access Point

1. Ensure the terminal emulation program is installed on the PC. 2. With both the PC and gateway/access point powered OFF, connect the communication cable to the appropriate PC COM port. 3. Connect the other end of the communication cable to the DIAG port on the gateway/access point. Turn the PC on. 4. After the PC boots, start the terminal emulation program. 5. Set the terminal emulation program’s options according to what you want to do: Access the configuration menus, or access the ROM command monitor.

Accessing the Configuration Menus 1. Set the terminal emulation parameters. If you are configuring this gateway/access point for the first time, set the parameters to the default settings for FLASH mode: 9600, E71, full duplex If you have already changed the default settings, set the parameters to those you set in FLASH mode through the configuration menus. 2. Plug the gateway/access point into the outlet. These messages appear (the first two are ROM power-up messages and the third is FLASH): Press any key within 5 seconds to enter ROM command monitor Executing file IGAP6910.BIN from segment <segment number> POWER UPMUX V9.22,16 (this is the default host port message)

2-8

6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide