Page 93

APPENDIX A

"

MIB ceLogTable OBJECT-TYPE SYNTAX SEQUENCE OF CELogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION ”Critical Error Log Table” ::= { criticalErrors 4 } ceLogEntry OBJECT-TYPE SYNTAX CELogEntry ACCESS not-accessible STATUS mandatory INDEX { ceLogErrorCode } ::= { ceLogTable 1 } CELogEntry ::= SEQUENCE { ceLogErrorCode INTEGER, ceLogErrorCount Counter } ceLogErrorCode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION ”Critical error code. A 16-bit value which uniquely indentifies a system software error. The error codes are intended for internal Norand use.” ::= { ceLogEntry 1 } ceLogErrorCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”Error count for the associated ceLogErrorCode” ::= { ceLogEntry 2 } nInterfaces

OBJECT IDENTIFIER ::= { norandNET 2 } nifx

OBJECT IDENTIFIER ::= { nInterfaces 2 }

-- The Norand Extended Interfaces Table nifxTable OBJECT-TYPE SYNTAX SEQUENCE OF NIFXEntry ACCESS not-accessible STATUS mandatory DESCRIPTION ”Norand Extended Interface Table” ::= { nifx 4 }

6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide

A-41

Page 94

APPENDIX A

"

MIB nifxEntry OBJECT-TYPE SYNTAX NIFXEntry ACCESS not-accessible STATUS mandatory INDEX { nifxIndex } ::= { nifxTable 1 } NIFXEntry ::= SEQUENCE { nifxIndex nifxType nifxInDisabledDiscards nifxInOverruns nifxInHWOverruns nifxInUcastDPkts nifxInNUcastDPkts nifxInLenErrors nifxExcessiveDeferrals nifxInNetIDDiscards nifxInFragDiscards nifxInUFilterDiscards nifxInNUFilterDiscards nifxInQFullDiscards } nifxIndex SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION ”Interface index” ::={ nifxEntry 1 } nifxType SYNTAX INTEGER {

INTEGER, INTEGER, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter

OBJECT-TYPE

OBJECT-TYPE ether(4), bb485(33), owlIP(66), proxim24(132), nor24(195), falcon902(197), uhf(198)

} ACCESS read-only STATUS mandatory DESCRIPTION ”Norand Interface Type” ::={ nifxEntry 2 }

A-42

6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide

Page 95

APPENDIX A

"

MIB nifxInDisabledDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”The number of received unicast frames which do not require forwarding. Unicast ethernet frames are discarded if ether-to-radio flooding is disabled and the destination is unknown; otherwise, unicast frames are discarded if the bridge has learned that the destination port is the same as the source port” ::={ nifxEntry 3 } nifxInOverruns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”The number of received frames discarded because the frame could not be queued for the MAC-D task” ::={ nifxEntry 4 } nifxInHWOverruns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”The number of received frames discarded due to hardware overruns.” ::={ nifxEntry 5 } nifxInUcastDPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”The number of received unicast frames successfully delivered to the MAC-D task” ::={ nifxEntry 6 } nifxInNUcastDPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”The number of received multicast frames successfully delivered to the MAC-D task” ::={ nifxEntry 7 }

6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide

A-43

Page 96

APPENDIX A

"

MIB nifxInLenErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”The number received frames with length errors” ::={ nifxEntry 8 } nifxExcessiveDeferrals OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”The number of aborted transmissions due to excessive deferrals” ::={ nifxEntry 9 } nifxInNetIDDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”The number of received frames discarded because the LAN ID did not match” ::={ nifxEntry 10 } nifxInFragDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”The number of received frame fragments discarded because a fragmented frame could not be re-assembled” ::={ nifxEntry 11 } nifxInUFilterDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”The number of enabled received unicast frames discarded due to a unicast filter expression” ::={ nifxEntry 12 } nifxInNUFilterDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”The number of enabled received multicast frames discarded due to a multicast filter expression” ::={ nifxEntry 13 }

A-44

6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide

Page 97

APPENDIX A

"

MIB nifxInQFullDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”The number of received frames discarded because the frame could not be queued for the MAC-R task” ::={ nifxEntry 14 } portState

OBJECT IDENTIFIER ::= { nInterfaces 3 }

-- The Port State Table psTable OBJECT-TYPE SYNTAX SEQUENCE OF PSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION ”MAC-R port state variables” ::= { portState 4 } psEntry SYNTAX PSEntry ACCESS not-accessible STATUS mandatory INDEX { psPort } ::= { psTable 1 }

OBJECT-TYPE

PSEntry ::= SEQUENCE { psPort INTEGER, psIfIndex INTEGER, psAddress PhysAddress, psType INTEGER, psState INTEGER, psCost INTEGER, psHelloPeriod INTEGER, psHelloCount Counter, psMacdWindow INTEGER, psMacdQSize Gauge, psMacdTimeouts Counter, psIsPrimary INTEGER, psIsSecondary INTEGER, psIsSecondaryCandidate INTEGER, psSecondaryUniFlooding INTEGER, psSecondaryMultiFlooding INTEGER, psIsRadio INTEGER, psPendEnabled INTEGER }

6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide

A-45

Page 98

APPENDIX A

"

MIB psPort SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION ”MAC-R port ID (1-4). the port.” ::= { psEntry 1 }

OBJECT-TYPE

A number which uniquely identifies psIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION ”MAC-D interface index. The index matches the interface index of the associated row in the mib-II interface table.” ::= { psEntry 2 } psAddress OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION ”802 address of the port” ::= { psEntry 3 } psType SYNTAX INTEGER {

OBJECT-TYPE ether(4), bb485(33), owlIP(66), proxim24(132), nor24(195), falcon902(197), uhf(198)

} ACCESS read-only STATUS mandatory DESCRIPTION ”Norand port type: ether = 4, Proxim = 196, Falcon = 197, UHF = 198” ::= { psEntry 4 }

A-46

6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide

Page 99

APPENDIX A

"

MIB

6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide

A-47 psState OBJECT-TYPE SYNTAX INTEGER { disabled(0), idle(1), open(2), receive(3), transmit(4) } ACCESS read-only STATUS mandatory DESCRIPTION ”Port state: disabled = 0, idle = 1, open = 2, receive = 3, transmit = 4 ” ::= { psEntry 5 } psCost OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION ”Incremental path cost of the port. Default values: ether = 20, Falcon = 100, UHF = 255 ” ::= { psEntry 6 } psHelloPeriod OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION ”Inter-HELLO time (.01 secs.)” ::= { psEntry 7 } psHelloCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”HELLO transmit count” ::= { psEntry 8 } psMacdWindow OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION ”Max. number of active MAC-D transmit requests” ::= { psEntry 9 }

Page 100

APPENDIX A

"

MIB psMacdQSize OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION ”Current number of active MAC-D transmit requests” ::= { psEntry 10 } psMacdTimeouts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”MAC-D transmit timeout errors” ::= { psEntry 11 } psIsPrimary OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION ”TRUE, for primary bridge ports” ::= { psEntry 12 } psIsSecondary OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION ”TRUE, for secondary bridge ports” ::= { psEntry 13 } psIsSecondaryCandidate OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION ”TRUE, if secondary bridge port candidates” ::= { psEntry 14 } psSecondaryUniFlooding OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION ”TRUE, for secondary bridge ports which require unicast flooding” ::= { psEntry 15 }

A-48

6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide

Page 101

APPENDIX A

"

MIB psSecondaryMultiFlooding OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION ”TRUE, for secondary bridge ports which require multicast flooding” ::= { psEntry 16 } psIsRadio OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION ”TRUE, for radio ports” ::= { psEntry 17 } psPendEnabled OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION ”TRUE, if the port supports pending messages” ::= { psEntry 18 } portStats

OBJECT IDENTIFIER ::= { nInterfaces 4 } pstcTable OBJECT-TYPE SYNTAX SEQUENCE OF PSTCEntry ACCESS not-accessible STATUS mandatory DESCRIPTION ”MAC-R port state variables” ::= { portStats 4 } pstcEntry SYNTAX PSTCEntry ACCESS not-accessible STATUS mandatory INDEX { pstcPort } ::= { pstcTable 1 }

OBJECT-TYPE

6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide

A-49

Page 102

APPENDIX A

"

MIB

PSTCEntry ::= SEQUENCE { pstcPort pstcInOWLPkts pstcInUcastOWLDataPkts pstcInNUcastOWLDataPkts pstcInOWLErrors pstcOutOWLPkts pstcOutUcastOWLDataPkts pstcOutNUcastOWLDataPkts pstcOutOWLErrors pstcParentLinkErrors pstcAlertLinkErrors pstcInUcastRelayPkts pstcInNUcastRelayPkts pstcOutUcastRelayPkts pstcOutNUcastRelayPkts pstcInUcastInbound pstcInUcastOutbound pstcInUcastSec pstcInUcastFlood pstcInUcastDiscards pstcInNUcastDiscards pstcInUcastToIFC pstcInNUcastToIFC pstcOutDelayDiscards } pstcPort SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION ”MAC-R port ID (1-4). the port.” ::= { pstcEntry 1 }

INTEGER, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter

OBJECT-TYPE

A number which uniquely identifies pstcInOWLPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”Total received OWL packets” ::= { pstcEntry 2 } pstcInUcastOWLDataPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”Received OWL unicast data packets” ::= { pstcEntry 3 }

A-50

6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide