The text of a manual · part 12 of 21
6910 Integrated and 6910 Telnet Gateway/Access Points User's Guide: Appendix A: MIB, pages 83 to 92
Pages 83 to 92 of 168, from 6910 Integrated and 6910 Telnet Gateway/Access Points User's Guide
The original document is the PDF (579 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Norand 6910 and Intermec 6910
Page 83
APPENDIX A
"
MIB
Table A-29 ahost GROUP Asynchronous Host norand.manage.norandNet.nApplication.ahost.x (1.3.6.1.4.1.469.1000.2.104.2.x) OID 1 2 3 4 5 6 7 8 9 10 11 12 13 15 16 17 18
Object Name ahstReset ahstLastReset ahstFramesOut ahstFramesIn ahstIdleDetected ahstNoErrors ahstSyntaxErrors ahstLengthErrors ahstDisabledErrors ahstGapErrors ahstCheckErrors ahstNoBuffersErrors ahstSequenceErrors ahstParityErrors ahstFrameErrors ahstNoiseErrors ahstBreakErrors
Object Type INTEGER TimeTicks Counter Counter Counter Counter Counter Counter Counter Counter Counter Counter Counter Counter Counter Counter Counter
Access write read read read read read read read read read read read read read read read read
6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide
A-31
Page 84
APPENDIX A
"
MIB
Table A-30 tgate GROUP (Applies only to the 6910 Telnet Gateway/Access Point) Gateway Connection Table norand.manage.norandNet.nApplication.tgate.x (1.3.6.1.4.1.469.1000.2.104.3.x) OID
Object Name
Object Type Access
3.1.1 3.1.2 3.1.3 3.1.4 3.1.5 3.1.6 3.1.7 3.1.8 3.1.9 tgateIndex tgateTerminal tgateHostIpAddress tgateHostPort tgateGatePort tgateEvent tgateEventAge tgateIdleTime tgateOfflineTime
INTEGER INTEGER IpAddress INTEGER INTEGER INTEGER TimeTicks TimeTicks TimeTicks read read read read read read read read read
Control Groups Objects in the following groups exert control over the 6710 Access Point. Present functions include rebooting and scheduling software downloads. " NOTE:
The MIB definition for each group starts on the page given below.
powerUp Power Up Objects (page A-110) " softwareDownLoad Software Download (page A-110) "
A-32
6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide
Page 85
APPENDIX A
"
MIB
Table A-31 powerUp GROUP Device Power Up Objects norand.manage.norandNet.nControl.powerUp.x (1.3.6.1.4.1.469.1000.2.105.1.x) OID
Object Name
Object Type Access
1 pwrPowerUpCount
Counter read
2 pwrNextPowerUpTime
TimeTicks write
Table A-32 softwareDownLoad GROUP Device Software Download norand.manage.norandNet.nControl.softwareDownLoad.x (1.3.6.1.4.1.469.1000.2.105.2.x) OID
Object Name
Object Type
Access
1 sdStartTime
TimeTicks write
2 sdServerIpAddress
IpAddress write
3 sdScriptFilename
DisplayString write
4 sdStatus
INTEGER
5 sdErrorString
DisplayString read
6 sdCheckPoint
INTEGER write
7 sdSetActivePointers
INTEGER write
8 sdTerminate
INTEGER write read
MIB Definitions Following are the MIB definitions for the 6910 Integrated Gateway/Access Point and 6910 Telnet Gateway/Access Point.
6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide
A-33
Page 86
APPENDIX A
"
MIB
-- ****************************************************************** -- * -- * 6910IMIB.MIB Version 1.32 -- * -- ****************************************************************** -- ****************************************************************** -- * -- * 6910TMIB.MIB Version 1.32 -- * -- ****************************************************************** OWL DEFINITIONS ::= BEGIN IMPORTS enterprises, IpAddress, Counter, Gauge, TimeTicks FROM RFC1155-SMI PhysAddress, DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212; ---
This MIB module uses the extended OBJECT-TYPE macro as defined in RFC-1212;
norand manage products ap6710 gw4030 wnas ts6950 gwap6910 uap2100 msd6710 norandNET nSystem hw
OBJECT IDENTIFIER ::= { enterprises 469 } OBJECT IDENTIFIER ::= { norand 1000 } OBJECT IDENTIFIER ::= { manage 1 } OBJECT IDENTIFIER ::= { products 1 } OBJECT IDENTIFIER ::= { products 2 } OBJECT IDENTIFIER ::= { products 3 } OBJECT IDENTIFIER ::= { products 4 } OBJECT IDENTIFIER ::= { products 5 } OBJECT IDENTIFIER ::= { products 6 } OBJECT IDENTIFIER ::= { products 7 } OBJECT IDENTIFIER ::= { manage 2 } OBJECT IDENTIFIER ::= { norandNET 1 } OBJECT IDENTIFIER ::= { nSystem 1 } -- The Hardware Parameters Group hwPartNo OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION ”The Norand part number of the hardware device.” ::= { hw 1 } hwDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-only STATUS mandatory DESCRIPTION ”The description of the hardware device.” ::= { hw 2 }
A-34
6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide
Page 87
APPENDIX A
"
MIB hwRevision OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION ”The revision level of the hardware device.” ::= { hw 3 } hwSerialNo OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION ”The serial number of the hardware device.” ::= { hw 4 } hwID OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION ”The device identifier of the hardware device. Values = 3250, 4000, 4020, 4030, 4033, 3240, 1000, 1100, 1700, 5940, 4650, 100 (ACE process), 200 (DOSNMS), 300 (Norand Proxy Agent), 6710 (Access Point).” ::= { hw 5 } file
OBJECT IDENTIFIER ::= { nSystem 3 } fsinfo
OBJECT IDENTIFIER ::= { file 1 }
-- The FileSystem Information Table fsEnabled OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION ”TRUE, if the file system is enabled” ::= { fsinfo 1 } fsMaxSectors OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION ”The number of physical sectors. A file segment consists of one or more adjacent physical sectors.” ::= { fsinfo 2 } fsSectorSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION ”The size of a physical sector in bytes.” ::= { fsinfo 3 }
6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide
A-35
Page 88
APPENDIX A
"
MIB fsNumSegments OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION ”The number of logical file segments (0-MAX_SECTORS)” ::= { fsinfo 4 } fsNumFiles OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION ”The number of files (0-25)” ::= { fsinfo 5 } fsBootSegment OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION ”The index of the current boot segment. If the index is non-zero and the first file in the associated segment is executable, then control is passed to that file during the power-up sequence.” ::= { fsinfo 6 } fsDataSegment OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION ”The index of the active data segment. Files stored in this segment will be accessible to an executing application.” ::= { fsinfo 7 } segment
OBJECT IDENTIFIER ::= { file 2 }
-- The File Segment Table -- Table Definition segTable OBJECT-TYPE SYNTAX SEQUENCE OF SEGEntry ACCESS not-accessible STATUS mandatory DESCRIPTION ”” ::= { segment 2 } -- Row Definition
A-36
6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide
Page 89
APPENDIX A
"
MIB segEntry OBJECT-TYPE SYNTAX SEGEntry ACCESS not-accessible STATUS mandatory INDEX { segID } ::= { segTable 1 } -- Columnar Object Definitions SEGEntry ::= SEQUENCE { segID INTEGER, segFirstSector INTEGER, segLastSector INTEGER, segStatus INTEGER, segSize INTEGER, segFree INTEGER } segID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION ”The segment ID (1 - (NUM_SEGMENTS+1)). A non-zero number which uniquely identifies a segment.” ::= { segEntry 1 } segFirstSector OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION ”The first physical sector in the segment (1 - (MAX_SECTORS + 1))” ::= { segEntry 2 } segLastSector OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION ”The last physical sector in the segment (FIRST_SECTOR - (MAX_SECTORS + 1))” ::= { segEntry 3 } segStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), invalid(2) } ACCESS read-only STATUS mandatory DESCRIPTION ”The segment status: valid = 1, invalid = 2 ” ::= { segEntry 4 }
6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide
A-37
Page 90
APPENDIX A
"
MIB segSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION ”The segment size in bytes” ::= { segEntry 5 } segFree OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION ”The number of available bytes in the segment which are not currently allocated to a file.” ::= { segEntry 6 } dir
OBJECT IDENTIFIER ::= { file 3 }
-- The File Directory Table -- Table Definition dirTable OBJECT-TYPE SYNTAX SEQUENCE OF DIREntry ACCESS not-accessible STATUS mandatory DESCRIPTION ”The FileSystem Directory” ::= { dir 2 } -- Row Definition dirEntry OBJECT-TYPE SYNTAX DIREntry ACCESS not-accessible STATUS mandatory INDEX { dirIndex } ::= { dirTable 1 } -- Columnar Object Definitions DIREntry ::= SEQUENCE { dirIndex INTEGER, dirName DisplayString, dirSegment INTEGER, dirType INTEGER, dirSize INTEGER, dirDate DisplayString, dirTime DisplayString, dirVersion DisplayString }
A-38
6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide
Page 91
APPENDIX A
"
MIB dirIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION ”Directory Index” ::= { dirEntry 1 } dirName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..14)) ACCESS read-only STATUS mandatory DESCRIPTION ”File name” ::= { dirEntry 2 } dirSegment OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION ”File segment (1 - (NUM_SEGMENTS + 1)). The segment ID which identifies the segment containing the file.” ::= { dirEntry 3 } dirType OBJECT-TYPE SYNTAX INTEGER { executable(1), data(2), invalid(3) } ACCESS read-only STATUS mandatory DESCRIPTION ”File type: executable = 1, data = 2, invalid = 3 ” ::= { dirEntry 4 } dirSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION ”The file size in bytes” ::= { dirEntry 5 } dirDate OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) ACCESS read-only STATUS mandatory DESCRIPTION ”The file date in MM-DD-YYYY display format.” ::= { dirEntry 6 }
6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide
A-39
Page 92
APPENDIX A
"
MIB dirTime OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-only STATUS mandatory DESCRIPTION ”The file time in HH:MM:SS display format.” ::= { dirEntry 7 } dirVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION ”The file version in v99.99 display format.” ::= { dirEntry 8 } sysErrors
OBJECT IDENTIFIER ::= { nSystem 4 } criticalErrors OBJECT IDENTIFIER ::= { sysErrors 1 } ceEnabled OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION ”A value of true(1) signifies that the critical error log was successfully initialized as part of the power-up sequence. Any errors in that initialization process result in a value of false(2).” ::= { criticalErrors 1 } ceOverflow OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION ”Overflow error code. If the overflow code is non-zero, it indicates that the log has overflowed and the overflow code contains the last displaced value.” ::= { criticalErrors 2 } ceReset OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-write STATUS mandatory DESCRIPTION ”A user can reset the critical error log by setting ceReset to true(1). Valid values are true(1) or false(2).” ::= { criticalErrors 3 }
A-40
6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide