The text of a manual · part 7 of 24
6710 Mobile Bridge User's Guide, pages 61 to 70
Pages 61 to 70 of 236
The original document is the PDF (1.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Norand 6710
Page 61
SECTION 4
"
Configuration
1. Ensure the 6710 Mobile Bridge is connected to the Ethernet cable, and has an assigned IP address and cable type. 2. Ensure the PC or workstation has an installed and configured Ethernet interface card. 3. Ensure the Telnet VT emulator is installed on the PC or workstation. 4. Open a new Telnet session on the PC or workstation. 5. Enter the 6710 Mobile Bridge’s IP address in the host name or IP address field. 6. See “Configuring the 6710 Mobile Bridge” on page 4-10.
Default and Site Settings The 6710 Mobile Bridge is factory configured with the default settings listed in the following charts. You may need to change the defaults to match the way your system is set up. You can record your site’s settings in the table for reference.
TCP/IP Options Option
Default
IP Address IP Subnet Mask IP Router IP Frame Type DHCP
0.0.0.0 255.255.255.0 0.0.0.0 DIX Enabled, if IP Address is zero Norand DHCP Server 5
DHCP Server Name Auto ARP Minutes
Site Setting
6710 Mobile Bridge User’s Guide
4-7
Page 62
SECTION 4
"
Configuration
Security Options Option
Default
Password Service Password
CR52401 Enabled
Site Setting
Bridge Options Option
Default
Serial Number Lan ID [Root] Root Priority [Global Flooding] Inbound Multicast Unicast Outbound to Secondaries Multicast Unicast [Ports] Ethernet port: Name MAC Address Status Hello Period [Ethernet] OWL Frame Type Cable Type [Static Addresses] [Normal RX Filter] [Frame Types] Action Scope
(Read-only) 0
4-8
6710 Mobile Bridge User’s Guide
1
Primary Disabled Disabled Disabled omde (Unique number) Enabled 2 seconds DIX Auto Detect 00:00:00:00:00:00
Pass Unlisted
Comments
Page 63
SECTION 4
Option
Default
[SubTypes 1] Action SubType Scope [SubTypes 2] Action SubType Scope [Advanced RX Filter] [Expressions] ExprSeq Offset Op Value Id Action [Values] Value RS-485 port: Name MAC Address Status Hello Period [B_B485] Baud Rate ARP Server Mode
"
Configuration
Comments
Pass (Various) (Various) Pass DIX--IP--TCP--Port 00 00
0 0 EQ 0 And 0 omd485a or omd485b (Ethernet MAC address) Enabled 2 seconds 115200 No Flooding
Notes:
6710 Mobile Bridge User’s Guide
4-9
Page 64
SECTION 4
"
Configuration
Configuring the 6710 Mobile Bridge When you create a local DIAG port or remote Telnet session with the 6710 Mobile Bridge, the configuration program’s password screen appears: Configuration of 6710 Mobile Bridge Copyright (c) 1995-1998 Intermec Technologies Corporation. All rights reserved. Portions copyright Epilogue Technology Corporation 1988-1995. All rights reserved
IP: Serial:
0.0.0.0 (Unique 10-digit number.)
Password:
" NOTE:
A different screen appears when you create a session through a Web browser. See page 4-46 for information about Web browser sessions.
The password screen shows the current settings for the IP address and serial number. It also shows the prompt for the top-level password. Enter the password (case insensitive) to display the Main Menu. The default password is CR52401.
Main Menu After you enter the top-level password, the Main Menu appears:
4-10
6710 Mobile Bridge User’s Guide
Page 65
SECTION 4
"
Configuration
Loading configuration from EEPROM Command File View Clear Read Write Reboot Exit ?
Description File system menu View/modify the configuration Set the configuration to default values Read the configuration from EEPROM Write the configuration to EEPROM Restart using last written configuration Disconnect Display this help
>
The menu lists the commands you can use to do various tasks, described on the following pages. The screen also displays the command prompt (>). At the prompt, type the name of the command you want to perform and press [Enter]. (Commands are case insensitive.) The Main Menu redisplays when you enter an invalid command. The following chart describes how to use the commands. Use
To
File
List file system commands and descriptions. Section 5, “Software Download,” describes the commands and file system methodology.
View
View or modify configuration program settings. See “Using the View Command” on page 4-12.
Clear
Reset the 6710 Mobile Bridge’s configuration to the factory-set default settings, which start on page 4-7.
Read
Load the most recent configuration from EEPROM. The configuration that was written to EEPROM since the 6710 Mobile Bridge was last rebooted becomes the new configuration.
6710 Mobile Bridge User’s Guide
4-11
Page 66
SECTION 4
"
Configuration
Use
To
Read The 6710 Mobile Bridge’s configuration is stored in (Continued) EEPROM. You reprogram the EEPROM whenever you change the configuration, write (save) the new configuration to EEPROM, and reboot the 6710 Mobile Bridge. Write Write (save) a new configuration to EEPROM. This command overwrites the previous configuration. You must write the new configuration to EEPROM and reboot the 6710 Mobile Bridge for any changes to take effect. Reboot Reboot the 6710 Mobile Bridge. You must reboot it for any changes you made to the configuration to take effect. Exit
Quit the configuration program. If you exit a new configuration without writing it to EEPROM, any changes you made are not saved.
?
Display online help for a command, option, or setting.
Using the View Command To view or modify configuration program settings, type View at the command prompt. The Main Options Menu appears: [Tcpip] [Bridge] [Security]
The following chart describes how to use the options.
4-12
6710 Mobile Bridge User’s Guide
Page 67
SECTION 4
"
Configuration
Use
To
[Tcpip] Page 4-14
Set options necessary for communications with this 6710 Mobile Bridge. The options apply to all TCP/IP ports. Telnet, SNMP, and HTTP communications are supported.
[Bridge] Page 4-21
Control the bridging of messages among the RS-485 and Ethernet ports for this 6710 Mobile Bridge. Settings to control interaction with other 6710 Mobile Bridges are also under the [Bridge] option. Set the configuration program’s top-level password and service password.
[Security] Page 4-45
The screens in this section show the options’ default settings. Some settings (such as the serial number) are unique to each 6710 Mobile Bridge. Other settings are automatically set and you cannot change them. This section identifies the settings you cannot change as “read-only.” The following chart shows how to navigate the View command’s menus and edit data. Press
To
[-] or [--]
Scroll up through items in a list.
[¯], [+], [=], or [Tab]
Scroll down through items in a list.
[®], [Enter], or [Spacebar]
Display an option’s settings or prompt after you highlight the option. Also use these keys to select the desired setting.
[¬], [Esc], or [Backspace]
Exit a menu or prompt.
[Esc]
Cancel editing.
[Enter]
Complete editing.
6710 Mobile Bridge User’s Guide
4-13
Page 68
SECTION 4
"
Configuration
TCP/IP Options Use [Tcpip] to set options necessary for communications with this 6710 Mobile Bridge, such as IP addresses. Addresses are required for remote setup or SNMP network management. Options are: IP Address IP Subnet Mask IP Router IP Frame Type DHCP DHCP Server Name Auto ARP Minutes
0.0.0.0 255.255.255.0 0.0.0.0 <DIX> <Enabled, if IP address is zero> “Norand DHCP Server” 5
IP Address IP Address is the unique address locally assigned to this 6710 Mobile Bridge. The prompt is: Range is: 4 nums 0..255
The default is 0.0.0.0, which disables the ability to use TCP/IP. Following are suggestions for setting the address: If you are installing this 6710 Mobile Bridge on an existing Ethernet segment, you should allocate the IP address from the same pool as the existing computers on the segment. " If you are installing this 6710 Mobile Bridge on a new Ethernet segment that is not going to connect to the Internet, try using this Class B address: 172.16.h.h
"
4-14
6710 Mobile Bridge User’s Guide
Page 69
SECTION 4
"
Configuration
The host number is “h.h.” This Class B network address is reserved by the numbering authority for a company’s internal use. If the Class B address appears on the Internet, routers drop the data. Note the following: If the IP address is 0.0.0.0 and DHCP is enabled, this IP address is obtained through DHCP. " If the IP address is 0.0.0.0 and DHCP is disabled, TCP/IP access to this 6710 Mobile Bridge is disabled. A discussion of DHCP starts on page 4-18. "
IP Subnet Mask IP subnets partition traffic and are connected by routers. The subnet mask indicates how many bits of the IP address represent a network number and how many indicate a host number. The prompt is: Range is: 4 nums 0..255
The default is 255.255.255.0. Following are suggestions for setting the subnet mask: If you are installing this 6710 Mobile Bridge on an existing Ethernet segment, the subnet mask should match the other computers on the segment. " If you are using the 172.16.h.h address suggested for IP Address, you may want to use a subnet mask of 255.255.248.0. This mask provides the network 172.16 with 30 subnets of 2046 computers each. "
6710 Mobile Bridge User’s Guide
4-15
Page 70
SECTION 4
"
Configuration
The IP address breakdown is: 16 bits of network address. " 5 bits of subnet address. Do not use all 0’s or all 1’s. " 11 bits of host address. Do not use all 0’s or all 1’s. The following chart lists IP addresses when the submask is 255.255.248.0. "
Subnet 1 2 3 . . . 30
First Address 172.16.8.1 172.16.16.1 172.16.24.1
Last Address 172.16.15.254 172.16.23.254 172.16.31.254
172.16.240.1
172.16.247.254
If you are using DHCP to obtain an IP subnet mask for this 6710 Mobile Bridge, the subnet mask obtained from DHCP overrides the setting for the IP Subnet Mask option.
IP Router " NOTE:
The IP address of the router is required only if this 6710 Mobile Bridge will communicate with devices on the other side of the router.
IP Router identifies the default router used to forward data frames to addresses on another subnet. The prompt is: Range is: 4 nums 0..255
4-16