Page 211

APPENDIX C

"

MIB rtHopAddr16 OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION “16-bit MAC-D address ( if rtHopAddrLen is twoByte(2) ).” ::= { rtEntry 9 } rtHopEaddr OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION “48-bit MAC-D address ( if rtHopAddrLen is sixByte(6) ).” ::= { rtEntry 10 } rtIsBound OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION “True if the destination is fully attached and the path can be used to forward data.” ::= { rtEntry 11 } rtIsRemote OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION “True if the destination is a non-OWL node.” ::= { rtEntry 12 } rtIsChild OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION “True if the destination is a child node.” ::= { rtEntry 13 } 6710 Mobile Bridge User’s Guide

C-59

Page 212

APPENDIX C

"

MIB rtIsAp OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION “True if the destination is an AP.” ::= { rtEntry 14 } rtIsDistributed OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION “True if the path is through a distributed AP (root node only).” ::= { rtEntry 15 } rtIsRemoteLan OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION “True if the destination is a remote LAN.” ::= { rtEntry 16 } rtNS OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION “MAC-R send sequence number for terminal nodes. The 16-bit (0-65535) sequence number of last OWL data request PDU sent to the destination.” ::= { rtEntry 17 }

C-60

6710 Mobile Bridge User’s Guide

Page 213

APPENDIX C

"

MIB rtNR OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION “MAC-R receive sequence number for terminal nodes. The 16-bit (0-65535) sequence number of the last OWL data request PDU received from the destination.” ::= { rtEntry 18 } brg

OBJECT IDENTIFIER ::= { nBridge 3 } -- The BRG Table -- Table Definition brgTable OBJECT-TYPE SYNTAX SEQUENCE OF BRGEntry ACCESS not-accessible STATUS mandatory DESCRIPTION “Each entry in this table provides bridge information for child nodes which are reachable via a bridge.” ::= { brg 2 } -- Row Definition brgEntry OBJECT-TYPE SYNTAX BRGEntry ACCESS not-accessible STATUS mandatory INDEX { brgDestination } ::= { brgTable 1 } -- Columnar Object Definition BRGEntry ::= SEQUENCE { brgDestination PhysAddress, brgPort INTEGER, brgAge INTEGER, brgType INTEGER, brgIsPermanent INTEGER, brgTimestamp TimeTicks } 6710 Mobile Bridge User’s Guide

C-61

Page 214

APPENDIX C

"

MIB

-- Leaf Definition brgDestination OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION “The 802 address of the destination.” ::= { brgEntry 1 } brgPort OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION “MAC-R port ID (1-4). A number which uniquely identifies the port.” ::= { brgEntry 2 } brgAge OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION “Time (in minutes) since the entry was updated.” ::= { brgEntry 3 } brgType SYNTAX INTEGER {

OBJECT-TYPE primary(1), secondary(2), inbound(4) }

ACCESS read-only STATUS mandatory DESCRIPTION “Entry Type: primary = 1, secondary = 2, inbound = 4.” ::= { brgEntry 4 }

C-62

6710 Mobile Bridge User’s Guide

Page 215

APPENDIX C

"

MIB brgIsPermanent OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION “TRUE, if the entry is permanent.” ::= { brgEntry 5 } brgTimestamp OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION “The time when the primary or inbound entry was added or the time when the secondary entry was added or reattached.” ::= { brgEntry 6 } addr

OBJECT IDENTIFIER ::= { nBridge 4 }

-- The Addr Table -- Table Definition addrTable OBJECT-TYPE SYNTAX SEQUENCE OF AddrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION “Each entry in this table provides address information for all OWL nodes in the network. table exists only at the root node.” ::= { addr 2 }

This

-- Row Definition addrEntry OBJECT-TYPE SYNTAX AddrEntry ACCESS not-accessible STATUS mandatory INDEX { addrDestination } ::= { addrTable 1 }

6710 Mobile Bridge User’s Guide

C-63

Page 216

APPENDIX C

"

MIB

-- Columnar Object Definition AddrEntry ::= SEQUENCE { addrDestination PhysAddress, addrAge INTEGER, addrNodeId INTEGER, addrAlias DisplayString, addrDeviceId INTEGER, addrIpAddress IpAddress } -- Leaf Definition addrDestination OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION “The 802 address of the registered port.” ::= { addrEntry 1 } addrAge OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION “The time (in minutes) since the entry was updated.” ::= { addrEntry 2 } addrNodeId OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION “16-bit (0-65535) node/port ID” ::= { addrEntry 3 } addrAlias OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION “An alias for the 802 address.” ::= { addrEntry 4 } C-64

6710 Mobile Bridge User’s Guide

Page 217

APPENDIX C

"

MIB addrDeviceId OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION “Device ID (0-65535). An OWL node can, optionally, set a device ID in a registration request PDU.” ::= { addrEntry 5 } addrIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION “32-bit IP address for IP nodes (e.g. APs).” ::= { addrEntry 6 } brgState

OBJECT IDENTIFIER ::= { nBridge 6 }

-- The Bridge State Group bsAddress SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION “802 address of the AP.” ::= { brgState 3 }

OBJECT-TYPE bsLanId SYNTAX INTEGER (0..254) ACCESS read-only STATUS mandatory DESCRIPTION “OWL LAN ID (0-254).” ::= { brgState 4 }

OBJECT-TYPE bsCostToRoot SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION “Path cost to the root.” ::= { brgState 5 }

OBJECT-TYPE

6710 Mobile Bridge User’s Guide

C-65

Page 218

APPENDIX C

"

MIB bsIsRoot OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION “TRUE, if the AP is the root.” ::= { brgState 6 } bsIsAttached OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION “TRUE, if the AP is attached.” ::= { brgState 7 } bsAttachId OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION “16-bit (0-65535) ATTACH sequence number. This number is incremented each time the AP sends an ATTACH request.” ::= { brgState 8 } bsMyRootPriority OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION “Root priority of the AP (0-7). An AP with a root priority of 0 cannot become the root node. The AP with the highest priority will become the root in an OWL LAN.” ::= { brgState 9 }

C-66

6710 Mobile Bridge User’s Guide

Page 219

APPENDIX C

"

MIB bsRootPort OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION “MAC-R root port number. The port number (1-4) of the port used to communicate with the parent node.” ::= { brgState 10 } bsDesignatedRootAddress OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION “802 address of the current root.” ::= { brgState 11 } bsDesignatedRootPriority OBJECT-TYPE SYNTAX INTEGER (1..7) ACCESS read-only STATUS mandatory DESCRIPTION “Root priority of the current root (1-7).” ::= { brgState 12 } bsDesignatedRootSequence OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION “Root sequence of the current root (0-255). The sequence number identifies a single instance of the root.” ::= { brgState 13 } bsParentAddress OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION “802 address of the parent AP.” ::= { brgState 14 } 6710 Mobile Bridge User’s Guide

C-67

Page 220

APPENDIX C

"

MIB bsPortCount SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION “Number of MAC-R ports” ::= { brgState 15 }

OBJECT-TYPE bsNodeId OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION “16-bit node ID (0-65535). The node ID uniquely identifies the node in an OWL LAN.” ::= { brgState 16 } bsRootChangedCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION “Number of times that the root has changed.” ::= { brgState 17 } bsRootCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION “Number of times that the AP became the root.” ::= { brgState 18 } bsAttachCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION “Number of times that the AP has changed from an unattached state to an attached state.” ::= { brgState 19 } C-68