For the Norand 6710

Page 171

APPENDIX C

MIB

" hwDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-only STATUS mandatory DESCRIPTION “The description of the hardware device.” ::= { hw 2 } hwRevision OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION “The revision level of the hardware device.” ::= { hw 3 } hwSerialNo OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION “The serial number of the hardware device.” ::= { hw 4 } hwID OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION “The device identifier of the hardware device. Values = 3250, 4000, 4020, 4030, 4033, 3240, 1000, 1100, 1700, 5940, 4650, 100 (ACE process), 200 (DOSNMS), 300 (Norand Proxy Agent), 6710 (Access Point).” ::= { hw 5 } file fsinfo

OBJECT IDENTIFIER ::= { nSystem 3 } OBJECT IDENTIFIER ::= { file 1 }

-- The File System Information Table 6710 Mobile Bridge User’s Guide

C-19

Page 172

APPENDIX C

"

MIB fsEnabled OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION “TRUE, if the file system is enabled.” ::= { fsinfo 1 } fsMaxSectors OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION “The number of physical sectors. A file segment consists of one or more adjacent physical sectors.” ::= { fsinfo 2 } fsSectorSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION “The size of a physical sector in bytes.” ::= { fsinfo 3 } fsNumSegments OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION “The number of logical file segments (0-MAX_SECTORS).” ::= { fsinfo 4 } fsNumFiles OBJECT-TYPE SYNTAX Gauge (0..25) ACCESS read-only STATUS mandatory DESCRIPTION “The number of files (0-25).” ::= { fsinfo 5 } C-20

6710 Mobile Bridge User’s Guide

Page 173

APPENDIX C

"

MIB fsBootSegment OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION “The index of the current boot segment. If the index is non-zero and the first file in the associated segment is executable, then control is passed to that file during the power-up sequence.” ::= { fsinfo 6 } fsDataSegment OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION “The index of the active data segment. Files stored in this segment will be accessible to an executing application.” ::= { fsinfo 7 } segment

OBJECT IDENTIFIER ::= { file 2 }

-- The File Segment Table -- Table Definition segTable OBJECT-TYPE SYNTAX SEQUENCE OF SEGEntry ACCESS not-accessible STATUS mandatory DESCRIPTION “A catalog of memory segments and their utilitization.” ::= { segment 2 } -- Row Definition segEntry OBJECT-TYPE SYNTAX SEGEntry ACCESS not-accessible STATUS mandatory INDEX { segID } ::= { segTable 1 } 6710 Mobile Bridge User’s Guide

C-21

Page 174

APPENDIX C

"

MIB

-- Columnar Object Definitions SEGEntry ::= SEQUENCE { segID INTEGER, segFirstSector INTEGER, segLastSector INTEGER, segStatus INTEGER, segSize INTEGER, segFree INTEGER } segID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION “The segment ID (1 - (NUM_SEGMENTS+1)). A non-zero number which uniquely identifies a segment.” ::= { segEntry 1 } segFirstSector OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION “The first physical sector in the segment (1 - (MAX_SECTORS + 1)).” ::= { segEntry 2 } segLastSector OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION “The last physical sector in the segment (FIRST_SECTOR - (MAX_SECTORS + 1)).” ::= { segEntry 3 }

C-22

6710 Mobile Bridge User’s Guide

Page 175

APPENDIX C

"

MIB segStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), invalid(2) } ACCESS read-only STATUS mandatory DESCRIPTION “The segment status: valid = 1, invalid = 2.” ::= { segEntry 4 } segSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION “The segment size in bytes.” ::= { segEntry 5 } segFree OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION “The number of available bytes in the segment which are not currently allocated to a file.” ::= { segEntry 6 } dir

OBJECT IDENTIFIER ::= { file 3 }

-- The File Directory Table -- Table Definition dirTable OBJECT-TYPE SYNTAX SEQUENCE OF DIREntry ACCESS not-accessible STATUS mandatory DESCRIPTION “The FileSystem Directory.” ::= { dir 2 }

6710 Mobile Bridge User’s Guide

C-23

Page 176

APPENDIX C

"

MIB

-- Row Definition dirEntry OBJECT-TYPE SYNTAX DIREntry ACCESS not-accessible STATUS mandatory INDEX { dirIndex } ::= { dirTable 1 } -- Columnar Object Definitions DIREntry ::= SEQUENCE { dirIndex INTEGER, dirName DisplayString, dirSegment INTEGER, dirType INTEGER, dirSize INTEGER, dirDate DisplayString, dirTime DisplayString, dirVersion DisplayString } dirIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION “Directory Index” ::= { dirEntry 1 } dirName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..14)) ACCESS read-only STATUS mandatory DESCRIPTION “File name” ::= { dirEntry 2 }

C-24

6710 Mobile Bridge User’s Guide

Page 177

APPENDIX C

"

MIB dirSegment OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION “File segment (1 - (NUM_SEGMENTS + 1)). The segment ID which identifies the segment containing the file.” ::= { dirEntry 3 } dirType OBJECT-TYPE SYNTAX INTEGER { executable(1), data(2), invalid(3) } ACCESS read-only STATUS mandatory DESCRIPTION “File type: executable = 1, data = 2, invalid = 3.” ::= { dirEntry 4 } dirSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION “The file size in bytes.” ::= { dirEntry 5 } dirDate OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) ACCESS read-only STATUS mandatory DESCRIPTION “The file date in MM-DD-YYYY display format.” ::= { dirEntry 6 }

6710 Mobile Bridge User’s Guide

C-25

Page 178

APPENDIX C

"

MIB dirTime OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-only STATUS mandatory DESCRIPTION “The file time in HH:MM:SS display format.” ::= { dirEntry 7 } dirVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION “The file version in v99.99 display format.” ::= { dirEntry 8 } sysErrors

OBJECT IDENTIFIER ::= { nSystem 4 } criticalErrors OBJECT IDENTIFIER ::= { sysErrors 1 } ceEnabled OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION “A value of true(1) signifies that the critical error log was successfully initialized as part of the power-up sequence. Any errors in that initialization process result in a value of false(2).” ::= { criticalErrors 1 } ceOverflow OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION “Overflow error code. If the overflow code is non-zero, it indicates that the log has overflowed and the overflow code contains the last displaced value.” ::= { criticalErrors 2 } C-26

6710 Mobile Bridge User’s Guide

Page 179

APPENDIX C

MIB

" ceReset OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-write STATUS mandatory DESCRIPTION “A user can reset the critical error log by setting ceReset to true(1). Valid values are true(1) or false(2).” ::= { criticalErrors 3 } ceLogTable OBJECT-TYPE SYNTAX SEQUENCE OF CELogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION “Critical Error Log Table” ::= { criticalErrors 4 } ceLogEntry OBJECT-TYPE SYNTAX CELogEntry ACCESS not-accessible STATUS mandatory INDEX { ceLogErrorCode } ::= { ceLogTable 1 } CELogEntry ::= SEQUENCE { ceLogErrorCode INTEGER, ceLogErrorCount Counter } ceLogErrorCode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION “Critical error code. A 16-bit value which uniquely identifies a system software error. The error codes are intended for internal Norand use.” ::= { ceLogEntry 1 } 6710 Mobile Bridge User’s Guide

C-27

Page 180

APPENDIX C

"

MIB ceLogErrorCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION “Error count for the associated ceLogErrorCode” ::= { ceLogEntry 2 } nInterfaces

OBJECT IDENTIFIER ::= { norandNet 2 } nifx

OBJECT IDENTIFIER ::= { nInterfaces 2 }

-- The Norand Extended Interfaces Table nifxTable OBJECT-TYPE SYNTAX SEQUENCE OF NIFXEntry ACCESS not-accessible STATUS mandatory DESCRIPTION “Norand Extended Interface Table” ::= { nifx 4 } nifxEntry SYNTAX NIFXEntry ACCESS not-accessible STATUS mandatory INDEX { nifxIndex } ::= { nifxTable 1 }

C-28

6710 Mobile Bridge User’s Guide

OBJECT-TYPE