The text of a manual · part 15 of 24
6710 Mobile Bridge User's Guide, pages 141 to 150
Pages 141 to 150 of 236
The original document is the PDF (1.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Norand 6710
Page 141
SECTION 6
"
Indicator Lights
STATUS The STATUS (left) light indicates the 6710 Mobile Bridge’s operating status. When the light is OFF, the 6710 Mobile Bridge is operating normally. When the light is ON, it is in error mode. " NOTE:
In certain cases the following text refers to the indicator lights by number. Lights are numbered from left to right. Light 1 is labeled LINK and Light 8 is labeled NIC2.
The 6710 Mobile Bridge enters error mode when it detects a malfunction during the power-on self tests or when certain hardware malfunctions occur during normal operation. When the STATUS light is ON to indicate the error mode, indicator lights 4 through 8 (the STATUS MODE light and the NETWORK and PCMCIA light pairs) display a binary error status code between 1 and 31. This code indicates the specific condition causing the error status as shown in Table 6-2. Descriptions of errors are on page 6-4. Table 6-2 Error Mode Status Codes Status Mode
R-LINK
W-LINK NIC1 NIC2 Error Status
ON
OFF
OFF
OFF
OFF
ON
Hardware error 1.
ON
OFF
OFF
OFF
ON
OFF
Hardware error 2.
ON
OFF
OFF
OFF
ON
ON
Hardware error 3.
ON
OFF
OFF
ON
OFF
OFF
Internal serial loopback test failed.
ON
OFF
OFF
ON
OFF
ON
Internal MACE AUI loopback test failed.
ON
OFF
OFF
ON
ON
OFF
Internal 10BASE-T loopback test failed.
ON
OFF
OFF
ON
ON
ON
Timer test failed.
6710 Mobile Bridge User’s Guide
6-3
Page 142
SECTION 6
" NOTE:
6-4
"
Indicator Lights
Contact the Customer Response Center for help with errors. Error Status
Description
Hardware errors 1, 2, and 3
These errors indicate an internal hardware error or malfunction. The errors can occur when you apply power to the 6710 Mobile Bridge. If it encounters a hardware error, it no longer functions.
Internal serial loopback test failed
This failure occurs if the 6710 Mobile Bridge does not successfully complete the power-on self-test. The error indicates a probable hardware malfunction associated with the DIAG port. In most cases, the unit continues to operate normally, but the error condition still exists.
Internal MACE (Media Access Controller for Ethernet) AUI loopback test failed
This failure occurs if the 6710 Mobile Bridge does not successfully complete the power-on self-test. The error indicates a probable hardware malfunction associated with the AUI port. In most cases, the unit continues to operate normally, but the error condition still exists.
Internal 10BASE-T loopback test failed
This failure occurs if the 6710 Mobile Bridge does not successfully complete the power-on self-test. The error indicates a probable hardware malfunction associated with the 10BASE-T port. In most cases, the unit continues to operate normally, but the error condition still exists.
Timer test failed
This failure occurs when the 6710 Mobile Bridge timer circuit malfunctions. If a timer error occurs, the unit no longer functions.
6710 Mobile Bridge User’s Guide
Page 143
SECTION 6
"
Indicator Lights
MODE The right STATUS light is labeled MODE. It indicates the current status of the 6710 Mobile Bridge (Table 6-3). Table 6-3 MODE Indicator Light Status
Indication
ON
6710 Mobile Bridge is not functional and is locked up.
BLINK
6710 Mobile Bridge is in network mode, the normal operating condition.
OFF
6710 Mobile Bridge is in command mode. It enters this mode when it detects a key press from an attached PC before it enters boot mode, or when it detects an incoming signal from an attached modem.
NETWORK MODE Lights NETWORK MODE indicator lights show the status of the 6710 Mobile Bridge’s network link. The lights are labeled R-LINK (left indicator) and W-LINK (right indicator). They work together to indicate the type of network link the 6710 Mobile Bridge has established. Table 6-4 shows links. Table 6-4 NETWORK MODE Indicator Lights R-LINK W-LINK Network Link Description OFF
OFF
OFF
ON
ON
ON
No network link established (6710 Mobile Bridge is not connected to the network, or is reconfiguring). 6710 Mobile Bridge is attached to the network through an Ethernet port. 6710 Mobile Bridge is operating as the super root.
6710 Mobile Bridge User’s Guide
6-5
Page 144
SECTION 6
"
Indicator Lights
PCMCIA Lights PCMCIA indicator lights show the status of the two PC card slots, which are labeled NIC1 and NIC2. The left light shows the status of NIC1; the right light shows the status of NIC2. Table 6-5 shows light indications for both ports. Table 6-5 PCMCIA Indicator Lights Status
Indication
OFF
A functional or enabled RS-485 PC card is not installed in the slot.
ON
A functional and enabled RS-485 PC card is installed in the slot.
When the 6710 Mobile Bridge reboots in ROM mode, the R-LINK, W-LINK, NIC1, and NIC2 indicator lights show, for about 9 seconds, the DIAG port’s baud rate. The lights show the status about 8 seconds after the W-LINK light stops blinking. Table 6-6 shows baud rates. Table 6-6 DIAG Port Baud Rates, ROM Mode
6-6
R-LINK
W-LINK
NIC1
NIC2
Baud Rate
OFF
OFF
OFF
ON
2400
OFF
OFF
ON
OFF
4800
OFF
OFF
ON
ON
9600
OFF
ON
OFF
OFF
14400
OFF
ON
OFF
ON
19200
OFF
ON
ON
OFF
28800
OFF
ON
ON
ON
38400
ON
OFF
OFF
OFF
57600
6710 Mobile Bridge User’s Guide
Page 145
SECTION 6
"
Indicator Lights
Power-Up Sequence When you power on the 6710 Mobile Bridge, it performs a power-up sequence that does the following: Tests the indicator lights. " Tests the functional circuits. " Determines the operational status. " Determines the boot sequence. You can monitor the power-up sequence through the indicator lights. During power-up the lights operate in this order: "
1. LINK indicator light turns ON and stays ON. 2. STATUS, MODE, R-LINK, W-LINK, NIC1, and NIC2 lights blink three times to indicate they are operational. 3. After the previous lights stop blinking, W-LINK light blinks three more times. 4. About eight seconds after W-LINK stops blinking, R-WINK, W-LINK, NIC1 and NIC2 lights either turn ON or stay OFF to indicate the DIAG port’s baud rate (see page 6-6). 5. MODE light blinks constantly to indicate it is in network mode, the normal operating condition. After the 6710 Mobile Bridge completes its boot sequence, it enters its normal operating mode. During normal operation the STATUS indicator light is OFF.
6710 Mobile Bridge User’s Guide
6-7
Page 146
SECTION 6
6-8
"
Indicator Lights
6710 Mobile Bridge User’s Guide
Page 147
Appendix A
Specifications "
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
Product Specifications Processor:
AMD 29200 RISC.
Memory:
4 MB RAM/2 MB FLASH ROM.
LAN compatibility:
ANSI/IEEE 802.3 (Ethernet communication standard) and DIX Version 2.0.
Interface:
10BASE2 (thinnet), 10BASE5 (AUI or thicknet), and 10BASE-T (twisted pair) through ports on bottom panel. RS-485 through ports on top panel.
Card slots:
Two RS-485 PC card slots.
Mounting options:
Tabletop or wall.
Electrical Specifications The 6710 Mobile Bridge has one IEC connector for industry-standard three conductor ac input. The bridge’s internal power supply automatically detects the voltage level and frequency of the source power. Following are source power specifications. Voltages:
Autosensing 100 to 240 V ac
Frequency:
50 to 60 Hz
Safety:
UL 1950 CAN/CSA--C22.2 No. 950--M93 IEC 950/EN 60950 (CB REPORT)
6710 Mobile Bridge User’s Guide
A-1
Page 148
APPENDIX A
"
Specifications
The 6710 Mobile Bridge complies with the following standards. Immunity:
EN (Euro Norm) 50082-1 Generic Immunity Standard
Emissions:
FCC Class B verified, IC ICES--003 Class B, CISPR* 22 (EN 55022) Class B radiated and conducted emissions under EN 50081-1, Generic Emissions Standard * Comite International Special des Perturpations Radioelecturques/International Special Committee on Radio Interference
Environmental Specifications Operating temperature (standard):
--22 dF to 122 dF (--30 dC to 50 dC)
Humidity:
Remains operational when exposed to 90 percent humidity, noncondensing conditions.
Physical Characteristics
A-2
Approximate size:
3.75 in x 6.88 in x 14.5 in (LWH) (9.5 cm x 17.5 cm x 36 cm)
Approximate weight:
3.75 lbs (1.70 kg)
6710 Mobile Bridge User’s Guide
Page 149
Appendix B
Port and Cable Pin-Outs "
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
This appendix lists pin-outs for the 6710 Mobile Bridge’s DIAG, RS-485, and AUI ports. It also shows pin-outs for the standard null modem (DIAG port) cable and RS-485 LAN cable.
DIAG Port Pin-Outs The following chart defines the signals present on the pins for the DIAG port. Pin numbering is from left to right and top to bottom. For example, pin 1 is on the top left of the connector, and the last pin is on the bottom right. Pin Number
Signal Name
1 2 3 4 5 6 7 8 9
Not used TXD RXD DTR GND DSR Not used Not used Not used
Signal Level RS-232 RS-232 RS-232 RS-232
6710 Mobile Bridge User’s Guide
B-1
Page 150
APPENDIX B
"
Port and Cable Pin-Outs
RS-485 Port Pin-Outs The following chart defines the signals present on the pins for the RS-485 port. Pin Number
Signal Name
2 3 7 8
RS-485+ RS-485-Ground Ground
AUI Port Pin-Outs The following chart defines the signals present on the pins for the AUI port. Pin numbering is from left to right and top to bottom. For example, pin 1 is on the top left of the connector, and the last pin is on the bottom right.
B-2
Pin Number
Signal Name
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
GND Data Data Not used Data GND Not used Not used Data Data Not used Data 12 V dc Not used Not used
6710 Mobile Bridge User’s Guide