For the Norand 6710

Page 141

SECTION 6

"

Indicator Lights

STATUS The STATUS (left) light indicates the 6710 Mobile Bridge’s operating status. When the light is OFF, the 6710 Mobile Bridge is operating normally. When the light is ON, it is in error mode. " NOTE:

In certain cases the following text refers to the indicator lights by number. Lights are numbered from left to right. Light 1 is labeled LINK and Light 8 is labeled NIC2.

The 6710 Mobile Bridge enters error mode when it detects a malfunction during the power-on self tests or when certain hardware malfunctions occur during normal operation. When the STATUS light is ON to indicate the error mode, indicator lights 4 through 8 (the STATUS MODE light and the NETWORK and PCMCIA light pairs) display a binary error status code between 1 and 31. This code indicates the specific condition causing the error status as shown in Table 6-2. Descriptions of errors are on page 6-4. Table 6-2 Error Mode Status Codes Status Mode

R-LINK

W-LINK NIC1 NIC2 Error Status

ON

OFF

OFF

OFF

OFF

ON

Hardware error 1.

ON

OFF

OFF

OFF

ON

OFF

Hardware error 2.

ON

OFF

OFF

OFF

ON

ON

Hardware error 3.

ON

OFF

OFF

ON

OFF

OFF

Internal serial loopback test failed.

ON

OFF

OFF

ON

OFF

ON

Internal MACE AUI loopback test failed.

ON

OFF

OFF

ON

ON

OFF

Internal 10BASE-T loopback test failed.

ON

OFF

OFF

ON

ON

ON

Timer test failed.

6710 Mobile Bridge User’s Guide

6-3

Page 142

SECTION 6

" NOTE:

6-4

"

Indicator Lights

Contact the Customer Response Center for help with errors. Error Status

Description

Hardware errors 1, 2, and 3

These errors indicate an internal hardware error or malfunction. The errors can occur when you apply power to the 6710 Mobile Bridge. If it encounters a hardware error, it no longer functions.

Internal serial loopback test failed

This failure occurs if the 6710 Mobile Bridge does not successfully complete the power-on self-test. The error indicates a probable hardware malfunction associated with the DIAG port. In most cases, the unit continues to operate normally, but the error condition still exists.

Internal MACE (Media Access Controller for Ethernet) AUI loopback test failed

This failure occurs if the 6710 Mobile Bridge does not successfully complete the power-on self-test. The error indicates a probable hardware malfunction associated with the AUI port. In most cases, the unit continues to operate normally, but the error condition still exists.

Internal 10BASE-T loopback test failed

This failure occurs if the 6710 Mobile Bridge does not successfully complete the power-on self-test. The error indicates a probable hardware malfunction associated with the 10BASE-T port. In most cases, the unit continues to operate normally, but the error condition still exists.

Timer test failed

This failure occurs when the 6710 Mobile Bridge timer circuit malfunctions. If a timer error occurs, the unit no longer functions.

6710 Mobile Bridge User’s Guide

Page 143

SECTION 6

"

Indicator Lights

MODE The right STATUS light is labeled MODE. It indicates the current status of the 6710 Mobile Bridge (Table 6-3). Table 6-3 MODE Indicator Light Status

Indication

ON

6710 Mobile Bridge is not functional and is locked up.

BLINK

6710 Mobile Bridge is in network mode, the normal operating condition.

OFF

6710 Mobile Bridge is in command mode. It enters this mode when it detects a key press from an attached PC before it enters boot mode, or when it detects an incoming signal from an attached modem.

NETWORK MODE Lights NETWORK MODE indicator lights show the status of the 6710 Mobile Bridge’s network link. The lights are labeled R-LINK (left indicator) and W-LINK (right indicator). They work together to indicate the type of network link the 6710 Mobile Bridge has established. Table 6-4 shows links. Table 6-4 NETWORK MODE Indicator Lights R-LINK W-LINK Network Link Description OFF

OFF

OFF

ON

ON

ON

No network link established (6710 Mobile Bridge is not connected to the network, or is reconfiguring). 6710 Mobile Bridge is attached to the network through an Ethernet port. 6710 Mobile Bridge is operating as the super root.

6710 Mobile Bridge User’s Guide

6-5

Page 144

SECTION 6

"

Indicator Lights

PCMCIA Lights PCMCIA indicator lights show the status of the two PC card slots, which are labeled NIC1 and NIC2. The left light shows the status of NIC1; the right light shows the status of NIC2. Table 6-5 shows light indications for both ports. Table 6-5 PCMCIA Indicator Lights Status

Indication

OFF

A functional or enabled RS-485 PC card is not installed in the slot.

ON

A functional and enabled RS-485 PC card is installed in the slot.

When the 6710 Mobile Bridge reboots in ROM mode, the R-LINK, W-LINK, NIC1, and NIC2 indicator lights show, for about 9 seconds, the DIAG port’s baud rate. The lights show the status about 8 seconds after the W-LINK light stops blinking. Table 6-6 shows baud rates. Table 6-6 DIAG Port Baud Rates, ROM Mode

6-6

R-LINK

W-LINK

NIC1

NIC2

Baud Rate

OFF

OFF

OFF

ON

2400

OFF

OFF

ON

OFF

4800

OFF

OFF

ON

ON

9600

OFF

ON

OFF

OFF

14400

OFF

ON

OFF

ON

19200

OFF

ON

ON

OFF

28800

OFF

ON

ON

ON

38400

ON

OFF

OFF

OFF

57600

6710 Mobile Bridge User’s Guide

Page 145

SECTION 6

"

Indicator Lights

Power-Up Sequence When you power on the 6710 Mobile Bridge, it performs a power-up sequence that does the following: Tests the indicator lights. " Tests the functional circuits. " Determines the operational status. " Determines the boot sequence. You can monitor the power-up sequence through the indicator lights. During power-up the lights operate in this order: "

1. LINK indicator light turns ON and stays ON. 2. STATUS, MODE, R-LINK, W-LINK, NIC1, and NIC2 lights blink three times to indicate they are operational. 3. After the previous lights stop blinking, W-LINK light blinks three more times. 4. About eight seconds after W-LINK stops blinking, R-WINK, W-LINK, NIC1 and NIC2 lights either turn ON or stay OFF to indicate the DIAG port’s baud rate (see page 6-6). 5. MODE light blinks constantly to indicate it is in network mode, the normal operating condition. After the 6710 Mobile Bridge completes its boot sequence, it enters its normal operating mode. During normal operation the STATUS indicator light is OFF.

6710 Mobile Bridge User’s Guide

6-7

Page 146

SECTION 6

6-8

"

Indicator Lights

6710 Mobile Bridge User’s Guide

Page 147

Appendix A

Specifications "

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

Product Specifications Processor:

AMD 29200 RISC.

Memory:

4 MB RAM/2 MB FLASH ROM.

LAN compatibility:

ANSI/IEEE 802.3 (Ethernet communication standard) and DIX Version 2.0.

Interface:

10BASE2 (thinnet), 10BASE5 (AUI or thicknet), and 10BASE-T (twisted pair) through ports on bottom panel. RS-485 through ports on top panel.

Card slots:

Two RS-485 PC card slots.

Mounting options:

Tabletop or wall.

Electrical Specifications The 6710 Mobile Bridge has one IEC connector for industry-standard three conductor ac input. The bridge’s internal power supply automatically detects the voltage level and frequency of the source power. Following are source power specifications. Voltages:

Autosensing 100 to 240 V ac

Frequency:

50 to 60 Hz

Safety:

UL 1950 CAN/CSA--C22.2 No. 950--M93 IEC 950/EN 60950 (CB REPORT)

6710 Mobile Bridge User’s Guide

A-1

Page 148

APPENDIX A

"

Specifications

The 6710 Mobile Bridge complies with the following standards. Immunity:

EN (Euro Norm) 50082-1 Generic Immunity Standard

Emissions:

FCC Class B verified, IC ICES--003 Class B, CISPR* 22 (EN 55022) Class B radiated and conducted emissions under EN 50081-1, Generic Emissions Standard * Comite International Special des Perturpations Radioelecturques/International Special Committee on Radio Interference

Environmental Specifications Operating temperature (standard):

--22 dF to 122 dF (--30 dC to 50 dC)

Humidity:

Remains operational when exposed to 90 percent humidity, noncondensing conditions.

Physical Characteristics

A-2

Approximate size:

3.75 in x 6.88 in x 14.5 in (LWH) (9.5 cm x 17.5 cm x 36 cm)

Approximate weight:

3.75 lbs (1.70 kg)

6710 Mobile Bridge User’s Guide

Page 149

Appendix B

Port and Cable Pin-Outs "

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

This appendix lists pin-outs for the 6710 Mobile Bridge’s DIAG, RS-485, and AUI ports. It also shows pin-outs for the standard null modem (DIAG port) cable and RS-485 LAN cable.

DIAG Port Pin-Outs The following chart defines the signals present on the pins for the DIAG port. Pin numbering is from left to right and top to bottom. For example, pin 1 is on the top left of the connector, and the last pin is on the bottom right. Pin Number

Signal Name

1 2 3 4 5 6 7 8 9

Not used TXD RXD DTR GND DSR Not used Not used Not used

Signal Level RS-232 RS-232 RS-232 RS-232

6710 Mobile Bridge User’s Guide

B-1

Page 150

APPENDIX B

"

Port and Cable Pin-Outs

RS-485 Port Pin-Outs The following chart defines the signals present on the pins for the RS-485 port. Pin Number

Signal Name

2 3 7 8

RS-485+ RS-485-Ground Ground

AUI Port Pin-Outs The following chart defines the signals present on the pins for the AUI port. Pin numbering is from left to right and top to bottom. For example, pin 1 is on the top left of the connector, and the last pin is on the bottom right.

B-2

Pin Number

Signal Name

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

GND Data Data Not used Data GND Not used Not used Data Data Not used Data 12 V dc Not used Not used

6710 Mobile Bridge User’s Guide