The text of a manual · part 10 of 15
RT1700 Radio Data Terminal User's Guide, pages 91 to 100
Pages 91 to 100 of 150
The original document is the PDF (1.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Norand 1700
Page 91
SECTION 3
"
Menu Screens
Link Test (UHF only)
The Link Test allows you to display data sent to the terminal, and respond to test signals from the host computer. Press [ENTER] to end the test and return to the Packet Driver menu.
Link Test Respond To Tests Enter to Exit
Link Watch (UHF only)
Link Watch allows you to view all data transmissions occurring in the terminal (between the terminal and the controller). Press [ENTER] to end the test and return to the Packet Driver menu.
Link Watch View All Traffic
Enter to Exit
RT1700 Radio Data Terminal User’s Guide
3-49
Page 92
SECTION 3
"
Menu Screens
Packet Stats
The Packet Stats (statistics) test shows the number of packets sent and received, number of errors, and number of packets dropped.
Receive Statistics Pkt Chr Err Lost xxx xxx xxx xxx
Transmit Statistics Pkt Chr Err xxx xxx xxx
Transaction Statistics Qty Sec Qty/Min Ops xxx xxx xxx xxx
RTC Statistics
3-50
RT1700 Radio Data Terminal User’s Guide
* SEE TEXT ‘HISTOGRAM OPTIONS’
Page 93
SECTION 3
"
Menu Screens
Histogram Opts
A technician or systems engineer may ask you to access this menu if your terminal has problems. From this menu you can provide that individual with vital information about your terminal. The actual menus are not shown in this manual, however some of the general terminology is shown below. Several of the menu options, such as “Clear. . ., ” are password-protected and will only be accessible if the technician or engineer provides you with the correct password. Terminology you might see: " avg tx time
" avg trans time
" ptt (push-to-talk) count
" addrs on list
" poll no data
" send retries
" rcv retries
" reset count
" interval time
" time bucket #
If you are asked to access the Stats Opts menus, the technician or engineer will walk you through it.
Histogram Opts 1) Start 2) Stop 3) View
RT1700 Radio Data Terminal User’s Guide
3-51
Page 94
SECTION 3
"
Menu Screens
Numbers
The Numbers test checks the operation of the terminal microprocessor. During the test, the terminal display is filled with hex numbers that march across the screen horizontally and scroll vertically. Character movement indicates the processor is still running. This test is helpful in detecting lockups during severe operating conditions. The Numbers test display is not shown here.
Version Info (Information) Version Info (Information) menu shows: "
The version of the program loaded in the firmware.
"
The release date of the firmware program.
"
The terminal identification number.
Use the Y(Up) or B(Down) arrows to view the version number of the EPROM program, and the H8 processor program The Version Info menu is shown below.
Version Info Firmware name Version Date
3-52
RT1700 Radio Data Terminal User’s Guide x.x ddmmyy
Page 95
SECTION 3
"
Menu Screens
Exit Menus The Exit Menus option (#6) gets you out of the terminal menus and returns the terminal to the power-up screen.
More The More selection opens Main Menu 2, which is shown below.
Main Menu 2 1) Keyboard Opts 2) Save Parms 3) Cloning Opts 4) Session Menu
Keyboard Opts (Options)
Use the Keyboard Opts menu to choose the Type-Ahead option. This lets you key in information when the terminal cannot immediately send data to the host computer.
Keyboard Opts 1) Type-Ahead
RT1700 Radio Data Terminal User’s Guide
3-53
Page 96
SECTION 3
"
Menu Screens
Save Parms
Save Parms retains the parameters you programmed into the terminal. When you save parameters, they become the default settings for the terminal. When you select Save Parms, you will be prompted to enter a sevendigit password (CR52401), as shown in the following. Once the password is correctly entered, the terminal automatically begins saving (writing to FLASH ROM) the parameters. " NOTE:
Use the Save Parms option sparingly. When you save parameters using this option, the changes are written to FLASH ROM and are not erased. Each time this option is used, it occupies additional FLASH ROM memory space.
Save Parms Enter Password > . . . . . . .
Save Parms Working Please Wait ........
3-54
RT1700 Radio Data Terminal User’s Guide
Page 97
SECTION 3
"
Menu Screens
Cloning Opts
This function allows you to “clone” (copy) either an application program or parameter settings from one terminal (the “source” terminal) to another (the “target” terminal). This requires a cloning cable and both terminals must be correctly set up for cloning. To clone an application program from one terminal to another: 1.
Connect the terminals using the cloning cable.
2.
Turn the source terminal ON, open the Cloning Opts menu, and select #1, “Clone Prgms.”
3.
Depress and hold the I key on the target (receiving) terminal, then switch it ON; the program from the source terminal will be downloaded into the target terminal.
To clone parameters from one terminal to another: 1.
Make sure the desired parameters are already set in the source terminal.
2.
Connect the terminals via the cloning cable.
3.
With both terminals ON, access the Cloning Opts menu.
4.
On the source terminal, select menu item #2, “Clone Parms.”
5.
On the target terminal, select menu item #3, “Receive Parms.”
Cloning Opts 1) Clone Prgms 2) Clone Parms 3) Receive Parms
RT1700 Radio Data Terminal User’s Guide
3-55
Page 98
SECTION 3
"
Menu Screens
Session Menu
The Session Menu allows you to define different host communication sessions and to designate a “hot key” that allows switching quickly between the different session. Use the Switch option to change the current session. The current (or intended) session must be identified (or designated) before setting Parameters. When you select Set Hot Key, the current hot key is displayed. Use the cursor up and down keys to view the available choices. When the desired key name is highlighted, press [ENTER] to make your selection. The Set Hot Key option is only available for terminals that support session switching.
Session Menu 1) Switch 2) Set Hot Key 3) Copy Setup
“Copy Setup” is password protected
Set Hot key
Select Session Use Cursor Up and Down Keys To Adjust Session: Host: <Datastream>
(1)
X XXXX XXX
“COPY SETUP” COPIES PARAMETERS OF BACKGROUND SESSION TO THE CURRENT SESSION.
3-56
RT1700 Radio Data Terminal User’s Guide
(3)
(2)
Use Cursor Up and Down Keys To Adjust
(2)
< xx >
Page 99
Section 4 Maintenance and Troubleshooting "
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
Introduction This section contains maintenance and troubleshooting procedures for the RT1700 Radio Data Terminal. Maintenance procedures include instructions on cleaning the terminal and replacing the hand strap. Troubleshooting procedures consist of problems that may be encountered when using a radio data terminal, and corrective measures you can take to isolate the problem or to restore normal operation.
Terminal Maintenance These terminals are designed to withstand normal use in your environment. However, the terminal does require occasional maintenance to ensure continued trouble-free operation. The following paragraphs include maintenance procedures that help keep your terminal in good working order. Battery Pack Maintenance
The RT1700 Radio Data Terminal contains a rechargeable battery pack. Depending upon the battery type, (e.g., nickel-cadmium or nickel metal-hydride), it will recharge inside the terminal within 2--3 hours after connection to a charging source. You can charge the battery pack in the terminal or outside the terminal. Instructions for charging the battery pack in the terminal are on page 2--4, in RT1700 Radio Data Terminal User’s Guide
4-1
Page 100
SECTION 4
"
Maintenance and Troubleshooting the paragraph Charging the Battery Pack in the Terminal. Instructions for charging the battery pack when it is removed from the terminal come with the charging device. Case Maintenance
The terminal case is designed to protect internal components from electrostatic discharges - commonly called static electricity - of up to 20,000 volts. The electronic components in the terminal can be damaged by the small electrostatic discharges (ESD) you experience nearly everyday (for instance, when turning on a light switch after walking across carpet, or getting out of your car after a short trip). The terminal case protects internal components from those discharges. In addition, the case is designed to protect the internal components of your terminal from accidental spills of noncorrosive liquids and to conceal minor scratches and blemishes. The following procedures explain what to do if liquid is spilled on the terminal, and how to clean the terminal when it becomes soiled. B CAUTION:
Do not use abrasives or solvents (or any product containing these substances) to clean the display. Permanent damage to the display cover will occur.
B CAUTION:
Never use ketonic solvents (acetone or ketone) or aromatic solvents (toluene or xylene) to clean any part of your terminal. Doing this can damage the terminal.
4-2