Page 222

Index, A - Abort Tag, 7-6 Accessing Calibration Switch, 5-4–5-6 ASCII Code Chart, 7-77 Auto-Zero, 2-11, B - Bar Codes Quality, 6-6 Recognition, 2-1 Bar Codes - 1 Parameters, 7-22–7-24 Bar Codes - 2 Parameters, 7-25–7-27 Bar Codes - 3 Parameters, 7-28–7-30 Bar Codes - 4 Parameters, 7-31–7-32 Bi-Optic Scanning, 2-2, C - C E Mark Applicability, xii Cables, 3-21–3-26 AC Power, 3-22 DC Power, 3-21 Hole Diameters, 3-21 Interface, Casio, 3-25 Interface, Data Checker, 3-26 Interface, Epson, 3-26 Interface, Gilbarco, 3-26 Interface, IBM, 3-27 Interface, ICL, 3-27 Interface, Microbilt, 3-28

Interface, NCR, 3-23–3-25 Interface, NEC, 3-28 Interface, SASI, 3-29 Remote Display, 3-22 Calibration Displaying audit trail, 5-2 General, 5-1 Procedures Accessing the Calibration Switch, 5-4 Connecting the Field Service Calibration Display, 5-7 Exercising the Scale, 5-3 Performing the Calibration, 5-9

Securing the Calibration Switch, 5-16 Verifying, 5-11–5-15 Weight Sets, 5-2 When to perform, 5-1 Which models, 5-1 Checkstand Considerations, 3-15 Display Clearance, 3-17 Item Diverter, 3-17 Service Clearance, 3-16 Ventilation, 3-15

Hole (Cutout, Bucket), 3-18 Dimensions (Models 1000 & 2000), 3-19 Dimensions (Models 3000, 4000, 4500), 3-20

Power Requirements, 3-9 Wiring Considerations, 3-2, 3-10 Europe, 3-11 Instructions, 3-13 International, 3-12 U.S., Canada, Japan, 3-10

Communications Protocol Parameters, 713–7-17

Page 223

Index-2, D - Declaration of Conformity, xiii Decode Features, 2-2 Default Tag, 7-7 Diagnostics Determining Communications Protocol, 4-10 Digital Board Kit for upgrade, 2-12 Dimensions Checkstand Hole Models 1000 & 2000, 3-19 Models 3000, 4000, & 4500, 3-20

Scanner/Scale Models 4000 & 4500, 3-32

Scanner/Scale, Model 3000, 3-31 Scanner/Scale, Models 1000 & 2000, 330 Displays, 2-3–2-5 Clearance. See Checkstand Field Service Calibration Display, 5-7 Integrated Display, 2-4 NCR 7825 Remote Display, 2-3 No Display, 2-5, E - End Tag, 7-7 Environmental Requirements, 3-7 Extreme Operating Range, 3-7 Operating Range, 3-7 Storage Range, 3-8 Transit Range, 3-8 Exercising the Scale, 5-3, F - Fault Identification, 8-1 Field Service Calibration Display, 5-7, G - Good Read Tone Changing, 6-10 Presets, 7-73 Good Read Tone Parameters, 7-18–7-19 Good Weight Tone, 7-74, H - Hex 0 - Hex F Tags, 7-7, I - Installation, 4-1–4-11 Getting Started, 4-1 Instructions, 4-3–4-7 Setting Scale Address for IBM, 4-11 Shipping Contents, 4-1 Verifying a Successful Installation, 4-8, K - Kits, 2-12, L - Label Orientation, 6-4 Labels Country Language Specific, xvi Laser Module, xvii Laser Safety, xv Scale Identification, xiv Laser, xvii Power Requirements, xvii Load Cell, 2-11, 5-1, M - Maintenance, 6-11 Miscellaneous Parameters, 7-55–7-58

Page 224

Index-3

Motion Detector, 6-3, N - NCR 7870 Scanner/Scale About, 1-2 Available Models, 1-2 Common Features, 1-3 Dimensions, 3-30 7870-1000 & 2000, 3-30 7870-3000, 3-31 7870-4000 & 4500, 3-32

Model Descriptions, 1-4 Not-On-File Error, 6-8, O - Operation Changing Good Read Tone, 6-10 Not-On-File Error, 6-8 Power Up, 6-7 Scanning Procedure, 6-8 Weighing Procedure, 6-9, P - PACESETTER Plus, 2-2–2-3, 7-59 Host Access to Tallies, 7-64 Kit for upgrade (OCIA/IBM), 2-12 Kit for upgrade (RS-232/Datachecker), 2-13 Mode 1, 2-2, 7-59 Mode 2, 2-3, 7-60 Mode 3, 2-3, 7-62 Power Supply, 2-5–2-6 Cables and Cords. See Cables Description, 2-5–2-6 Power Up, 6-7 Programming ASCII Code Chart, 7-77

General, 7-2 How to Program the NCR 7870, 7-3 Parameters, 7-25–7-27 Bar Codes - 1, 7-22–7-24 Bar Codes - 3, 7-28–7-30 Bar Codes - 4, 7-31–7-32 Communications Protocol, 7-17 Good Read Tone, 7-18–7-19 Label Identifiers, 7-33–7-38 Miscellaneous Parameters, 7-55–7-58 RS-232 Communications Options, 7-49–7-52 RS-232 Parameters - 2, 7-42–7-44 RS-232 Parameters- 1, 7-39–7-41 RS-232 Prefix Byte, 7-45–7-46 RS-232 Terminator Byte, 7-47–7-48 Scale Parameters, 7-53–7-54 Timers, 7-20–7-21

Program Entry Example, 7-9–7-11 Programming Mode, 7-5 Programming Tags, 7-6 Quick Reference Defaults Table, A-3– A-5 Special Programming, 7-68–7-76 Tips, 7-12 Programming Mode Tag, 7-8 Programming Parameters, 2-6 Programming Worksheets Quick Reference Defaults Table, A-3– A-5 Worksheets, A-3–A-5, R - Radio Frequency Interference Statements, xi Reading the Product (Model) Number, 13 Reset / Scale Zero, 2-11, 6-3 Revision Record, x RS-232 Communications Options Parameters, 7-49–7-52 RS-232 Parameters - 2, 7-42–7-44

Page 225

Index-4

RS-232 Parameters -1, 7-41 RS-232 Prefix Byte Parameters, 7-45–7-46 RS-232 Terminator Byte Parameters, 747–7-48, S - Save and Reset Tag, 7-8 Scale Functions and Features, 2-11 Auto-Zero, 2-11 Load Cell, 2-11 Reset / Scale Zero, 2-11

Market Certifications, 2-7 Regulatory, xii Troubleshooting, 8-3 Weighting Procedure, 6-9 Scale Calibration, 5-1, 5-2 Scale Parameters, 7-53–7-54 Scan Windows, 6-2 Maintenance, 6-11 Side Scan Window Kit for, 2-12

Slot Scan Window Kit for, 2-12

Scanner Active Scan Zone, 6-5 Bar Code Quality, 6-6 Bioptic, 2-2 Description, 2-5 Multiple Reads, 6-5 Power Requirements, 2-8 Scan Zone, 2-8 Scanning Procedure, 6-8 Troubleshooting, 8-2 Use of, 6-4 Scanner Windows Side Scanner Window Description, 2-10

Slot Scanner Window

Description, 2-9

Securing the Calibration Switch, 5-16–517, 5-16–5-17 Site Preparation, 3-1–3-20 Cable Lengths and Hole Diameters. See Cables Checkstand Power and Wiring Considerations. See Checkstand Customer Responsibilities, 3-6 Environmental Requirements. See Environmental Requirements Legal Considerations, 3-4–3-5 Site Preparations Assessing Local Conditions, 3-2–3-3 Soft Power Down, 2-8 Special Programming, 7-68–7-76 Delay Weight Data to IBM, 7-68 EAN/JAN/UPC Multi-Symbol Scanning Parameters, 7-69 Early Beep Disable, 7-72 Good Read Tone Presets, 7-73 Good Weight Tone, 7-74 Terminal Coupon Interface Parameters, 7-75–7-76 Standard Decode, 2-2, T - Tallies, 7-64 Terminal Coupon Interface Parameters, 7-75–7-76 Timers Parameters, 7-20–7-21 Tone, 6-3 Top Plate Description, 2-9 Kit for Scratch-Proof (Sapphire) Window, Model 3000, 2-16 Kit for Scratch-Proof (Sapphire) Window, Models 1000 & 2000, 2-16

Page 226

Index-5

Kit for Stainless Steel, 2-12 Maintenance, 6-11 Troubleshooting, 8-1–8-5 Fault Identification, 8-1 Scale, 8-3 Scanner, 8-2 Voice Messages, 8-5, V - Verifying Calibration, 5-11–5-15 Voice Messages, 6-3 Troubleshooting, 8-5, W - Worksheets, A-3–A-5

Page 227

Cut

Please answer the questions and mail the form. READER COMMENTS

How do you rate the technical accuracy of this document? 1

2

3

4

5

How do you rate the organization of this document? 1

2

3

4

5

How easy is it for you to locate specific information in this document? Very Difficult

1

2

3

4

5

Very Easy

5

Extremely Well

How well did this document help you perform your job? Not Well

1

2

3

4

Additional comments - use space below or back of form as necessary.

If we may contact you concerning your comments, please provide the following.

Name Address

Phone Fax E-Mail BST0-2121

Issue G

NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES

BUSINESS REPLY MAIL FIRST CLASS MAIL

PERMIT NO. 3

DAYTON, OH

POSTAGE WILL BE PAID BY ADDRESSEE

NCR Corporation Information Products 2651 Satellite Boulevard Duluth, GA 30096-5810

Cut

Cut

Fold

Page 228

BST0-2121-90

Nov. 1999

Printed on recycled paper