Page 195

Chapter 8: Troubleshooting

This chapter discusses the troubleshooting a user may perform to diagnose problems which may occur during use of the NCR 7870. For more comprehensive repair and service information, refer to the NCR 7870 Scanner/Scale Repair Guide (D2-0966-A).

Fault Identification The NCR 7870 Scanner/Scale performs internal diagnostic checks upon various functions during operation and the power-up sequence. Scanner operational problems are signaled by • a series of tones,

•

Voice Messages (if available), and

•

Status Indicator light flashing.

Scale operational problems are signaled by an error code displayed on the NCR 7825 Remote Display or the integrated display. Like the scanner, the scale unit performs diagnostic checks during the power-up sequence and while in operation. Troubleshooting consists of troubleshooting charts that are designed for locating and correcting certain problems without the aid of a trained technician. If the problem cannot be corrected by using these charts, a trained technician can then use the on-board diagnostics to help identify a faulty component.

Page 196

8-2

Chapter 8: Troubleshooting

Scanner Troubleshooting Chart Problem

Status Indicator

Tone

Possible Cause

Corrective Action

Scanner does not operate

Red Off Green Off

Off

No power

Check outlet for proper power

Scanner does not operate

Red Flashing Green Flashing

Off

Sleep mode

Pass anything in front of Motion Detector

Scanner does not operate

Red Flashing

Off

Communication 1. Verify the IBM terminal is IBM 468x and is off. scanner is off2. Verify the IBM terminal line is recognizing the 7870. 3. Verify the Interface Cable is properly connected. Host terminal has sent a “disable scanner” command

Scanner does not read tags

Red On

Off

Internal failure

1. Turn off circuit breaker to the 7870 then turn back on. 2. If problem remains, have the 7870 repaired.

Scanner reads only two tags

Red On

Off

7870 is not communicating with host terminal

1. Check host terminal for proper operation. 2. Verify the Interface Cable is properly connected.

Page 197

Chapter 8: Troubleshooting

8-3

Scale Troubleshooting Chart Note: This information does not apply to the NCR 7870-4000 which uses a Bizerba scale. For information on troubleshooting or servicing an NCR 7870-4000 scale unit, refer to the Bizerba documentation or contact the Bizerba representative.

Problem

Possible Cause

Corrective Action

Error code 5 - - - displays

Scale drift

1. Verify nothing is on scale. 2. Lift Top Plate and verify no objects are under it. 3. Push Reset/Scale Zero button. 4. Power down/up unit. 5. If error code persists, have unit repaired.

Error code 4 - - - displays

Possible scale error

1. Press Scale Zero button and retry.

Error code 4 - - - displays during calibration

Slight vibration to scale during calibration

Calibrate scale. Ensure there is no external scale movement while weights are on scale.

Scale display is blank

Top Plate prevented from moving down

1. Remove any interference around edge of Top Plate and checkstand.

2. If error code persists, have unit repaired.

2. Remove any foreign objects from under Top Plate. 3. Push Reset/Scale Zero button. Intermittent error codes

+12 VDC is unstable

Have 7870 repaired.

Page 198

Chapter 8: Troubleshooting

8-5

Voice Messages Troubleshooting Chart Problem

Possible Cause

Corrective Action

No Voice Messages

Firmware does not have voice capability.

Check firmware on the Digital Board. •

Power unit OFF and then ON.

•

Scan the Diagnostic Mode tag.

•

Scan Hex 4 and Hex A tags.

Firmware version should appear in display. Version must be 497-0301951 or higher to have Voice Messaging feature. Voice Messages option turned off.

Toggle Voice Messages Option. •

Power unit OFF and then ON.

•

Scan Programming Mode tag.

•

Scan Hex 3, Hex 2, and Hex D tags.

This will turn option on if it were off.

Page 199

8-6

Chapter 8: Troubleshooting