Page 195
Chapter 8: Troubleshooting
This chapter discusses the troubleshooting a user may perform to diagnose problems which may occur during use of the NCR 7870. For more comprehensive repair and service information, refer to the NCR 7870 Scanner/Scale Repair Guide (D2-0966-A).
Fault Identification The NCR 7870 Scanner/Scale performs internal diagnostic checks upon various functions during operation and the power-up sequence. Scanner operational problems are signaled by • a series of tones,
•
Voice Messages (if available), and
•
Status Indicator light flashing.
Scale operational problems are signaled by an error code displayed on the NCR 7825 Remote Display or the integrated display. Like the scanner, the scale unit performs diagnostic checks during the power-up sequence and while in operation. Troubleshooting consists of troubleshooting charts that are designed for locating and correcting certain problems without the aid of a trained technician. If the problem cannot be corrected by using these charts, a trained technician can then use the on-board diagnostics to help identify a faulty component.
Page 196
8-2
Chapter 8: Troubleshooting
Scanner Troubleshooting Chart Problem
Status Indicator
Tone
Possible Cause
Corrective Action
Scanner does not operate
Red Off Green Off
Off
No power
Check outlet for proper power
Scanner does not operate
Red Flashing Green Flashing
Off
Sleep mode
Pass anything in front of Motion Detector
Scanner does not operate
Red Flashing
Off
Communication 1. Verify the IBM terminal is IBM 468x and is off. scanner is off2. Verify the IBM terminal line is recognizing the 7870. 3. Verify the Interface Cable is properly connected. Host terminal has sent a “disable scanner” command
Scanner does not read tags
Red On
Off
Internal failure
1. Turn off circuit breaker to the 7870 then turn back on. 2. If problem remains, have the 7870 repaired.
Scanner reads only two tags
Red On
Off
7870 is not communicating with host terminal
1. Check host terminal for proper operation. 2. Verify the Interface Cable is properly connected.
Page 197
Chapter 8: Troubleshooting
8-3
Scale Troubleshooting Chart Note: This information does not apply to the NCR 7870-4000 which uses a Bizerba scale. For information on troubleshooting or servicing an NCR 7870-4000 scale unit, refer to the Bizerba documentation or contact the Bizerba representative.
Problem
Possible Cause
Corrective Action
Error code 5 - - - displays
Scale drift
1. Verify nothing is on scale. 2. Lift Top Plate and verify no objects are under it. 3. Push Reset/Scale Zero button. 4. Power down/up unit. 5. If error code persists, have unit repaired.
Error code 4 - - - displays
Possible scale error
1. Press Scale Zero button and retry.
Error code 4 - - - displays during calibration
Slight vibration to scale during calibration
Calibrate scale. Ensure there is no external scale movement while weights are on scale.
Scale display is blank
Top Plate prevented from moving down
1. Remove any interference around edge of Top Plate and checkstand.
2. If error code persists, have unit repaired.
2. Remove any foreign objects from under Top Plate. 3. Push Reset/Scale Zero button. Intermittent error codes
+12 VDC is unstable
Have 7870 repaired.
Page 198
Chapter 8: Troubleshooting
8-5
Voice Messages Troubleshooting Chart Problem
Possible Cause
Corrective Action
No Voice Messages
Firmware does not have voice capability.
Check firmware on the Digital Board. •
Power unit OFF and then ON.
•
Scan the Diagnostic Mode tag.
•
Scan Hex 4 and Hex A tags.
Firmware version should appear in display. Version must be 497-0301951 or higher to have Voice Messaging feature. Voice Messages option turned off.
Toggle Voice Messages Option. •
Power unit OFF and then ON.
•
Scan Programming Mode tag.
•
Scan Hex 3, Hex 2, and Hex D tags.
This will turn option on if it were off.
Page 199
8-6