Page 137

Chapter 7: Programming

7-21

Active Time (Minutes) You can program specific lengths of time that your NCR 7870 Scanner/Scale stays on after the last good read. There are four options in the Active Time parameter: no shut down, shut down after 15 minutes, shut down after 30 minutes, and shut down after 60 minutes. Select these times using the Hex 0 through Hex 3 tags, respectively. The default time is 15 minutes. Selecting no shut down results in the scanner/scale being active all the time. Note: NCR suggests that you do not set the Active Time parameter to “no shut down.” Leaving the laser light on all the time reduces its life expectancy.

Program Example Following is an example of a completed Timer programming worksheet. In this example the time-outs are programmed for the following. •

Lockout Time – 900 milliseconds

•

Restart Lockout Timer – off

•

Active Time – 30 minutes

Your Program

1 Timers

2

A

B

C

3

0

2

Lockout Time

Restart Timer

Active Time 11814

Page 138

7-22

Chapter 7: Programming

Bar Codes – 1 The Bar Codes 1 programming mode contains programming parameters for UPC/EAN bar codes.

Defaults Parameter

Default Value

UPC/EAN

Enable

Version D

None

Extend UPC-A to EAN-13

Disable

Extend UPC-E to UPC-A

Disable

Periodic Codes

Disable

Periodic Codes Extension

2-Digit & 5-Digit

Send Data

Data as Decoded

Specific Program Parameters UPC/EAN The UPC/EAN parameter controls reading UPC/EAN bar codes. Disable reading UPC/EAN bar codes by scanning the Hex 0 tag and enable reading by scanning the Hex 1 tag. The default is to enable reading. If you choose to disable reading UPC/EAN bar codes, there are no other entries allowed for this parameter. However, if you enable reading UPC/EAN bar codes, you can program the remaining parameters. Version D The Version D parameter permits you to enable or disable reading UPC Version D bar codes. There are six choices: None, D-1, D-2, D-3, D-4, and D-5. Scan the appropriate Hex 0 through Hex 5 tag to input

Page 139

Chapter 7: Programming

7-23 this parameter. The default is None and scanning a valid Hex tag ends the input for this parameter option. Extend UPC-A to EAN-13 The Extend UPC-A to EAN-13 parameter determines whether to pad the tag data, changing 12-digit UPC tags to 13-Character EAN tags. The program does this by putting a zero (0) at the front of the tag data. Scan the Hex 0 tag to disable this option or the Hex 1 tag to enable it. The default is Disable and scanning a valid Hex tag ends the input for this parameter option. Extend UPC-E to UPC-A The Extend UPC-E to UPC-A parameter determines whether to pad the tag data, changing 6-digit truncated UPC tags to 12-Character UPC-A tags. Scan the Hex 0 tag to disable this option or the Hex 1 tag to enable it. The default is Disable and scanning a valid Hex tag ends the input for this parameter option. Periodic Codes The Periodical Codes parameter controls the processing of Periodical Codes. Disable Periodical Codes by scanning the Hex 0 tag and enable them by scanning the Hex 1 tag. The default is to disable Periodical Codes. If you choose to disable Periodical Codes, there are no other entries allowed for this parameter. Scanning the Hex 0 tag also causes the scanner/scale to go back to the Base Programming State. However, if you enable Periodical Codes, you must also program the Periodical Code Extension and Send Data parameters. Note: Use of optional add-on bar codes may require additional programming. See Early Beep Disable and Terminal Coupon Interface Parameters in the Special Programming section of this chapter. Periodic Code Extension The Periodical Code Extension parameter has three selections: 2-digit extension only, 5-digit extension only, and either 2- or 5-digit extensions. Scan the Hex 0 tag for 2-digit extension only, the Hex 1 tag for 5-digit extension only, or the Hex 2 tag for both the 2- and 5-digit

Page 140

7-24

Chapter 7: Programming extension. The default is 2- and 5-digit extensions and scanning a valid Hex tag causes the program to go to the next parameter option. Send Data The Send Data parameter has three selections: Data As Decoded, Periodical Code Data Only, and CF Hex If Periodical Data Not Decoded. If you scan the Hex 0 tag, the data is sent as decoded, whether or not there are extension digits. If you scan the Hex 1 tag, only valid periodical codes are sent. If you scan the Hex 2 tag, a hexadecimal CF is sent as the extension if the scanner/scale could not read a 2- or 5-digit code. The default is Data as Decoded. Scanning a valid Hex tag causes the program to go to the Base Programming State.

Program Example In this example the UPC/EAN bar codes are programmed to have: •

UPC/EAN – enabled

•

Version D tags – not read

•

Extend UPC-A to EAN-13 – disabled

•

Extend UPC-E to UPC-A – disabled

•

Periodical Codes – enabled

•

Periodical Code Extensions – 2- and 5-digit extensions

•

Send data data – as decoded

Your Program

1

3

Bar Codes - 1

A

B

C

D

E

1

0

0

0

1

UPC/EAN Version D

2

0

Extend Extend Periodical Periodical Send UPC-A UPC-E Codes Code Data Extension

B055

Page 141

Chapter 7: Programming

7-25

Bar Codes – 2 The Bar Codes 2 programming mode contains programming parameters for Code 39.

Defaults Parameter

Default Value

Code 39

Disable

Minimum Characters Allowed

8

Full ASCII

Disable

Check Digit Present

Disable

Transmit Check Digit

Disable

Allow 1-or-2 Character Tags

Disable

Specific Program Parameters Code 39 The Code 39 parameter controls reading Code 39 bar codes. Disable reading Code 39 bar codes by scanning the Hex 0 tag and enable reading by scanning the Hex 1 tag. The default is to disable reading. If you choose to disable reading Code 39 bar codes, there are no other entries allowed for this parameter. However, if you enable reading Code 39 bar codes, you can program the rest of the parameters. Minimum Characters Allowed The Minimum Characters Allowed parameter defines how many characters in a bar code must be read the same by two separate scans before determining a valid read has occurred. You should set this option to the number of characters in a typical tag. This ensures that the scanner/scale reads typical tags with at least two complete good scans before sending the tag data to the host terminal.

Page 142

7-26

Chapter 7: Programming

There are 15 selections for this parameter option (2 through 16 characters). Scan the proper Hex tag (Hex 2 through Hex F) to enter your selection. The default is 4 characters. Full ASCII Code 39 permits full ASCII capability by encoding the additional characters. Disable this function by scanning the Hex 0 tag, and scan the Hex 1 tag to enable this function. Disable is the default. Check Digit Present The Check Digit Present parameter permits you to determine if the bar code must contain a correct check digit to be identified as valid. If this function is enabled, the bar code is ignored if a check digit is not present. Scan the Hex 0 tag to disable this option, or the Hex 1 tag to enable it. Disable is the default. Transmit Check Digit The Transmit Check Digit parameter selects whether to send the check digit to the host terminal. Scan the Hex 0 tag to disable this option, or the Hex 1 tag to enable it. The default is to disable sending the check digit. Allow 1- or 2-Character Tags The Allow One- or Two-Character Tags parameter selects whether or not to permit the scanner to read a one- or two-character Code 39 label. If your application does not require that the scanner read a one- or two-character Code 39 label, scan the Hex 0 tag to disable this option. If your application requires this capability, scan the Hex 1 tag to enable it. The default is to disable reading a one- or two-character Code 39 label.

Page 143

Chapter 7: Programming

7-27

Program Example Following is an example of a completed Bar Codes 2 programming worksheet. In this example, Code 39 is enabled with the following options. •

Code 39 – enabled

•

Minimum Characters Allowed – 5

•

Full ASCII – disabled

•

Check Digit Present – enabled

•

Transmit Check Digit – enabled

•

Allow One- or Two-Character Tags – disabled

Your Program

1

4

Bar Codes - 2

A

B

C

D

E

F

1

5

0

1

1

0

Code 39

Minimum Characters Allowed

Full ASCII

Check Digit Present

Transmit Check Digit

Allow Single Character Tags R0068

Page 144

7-28

Chapter 7: Programming

Bar Codes – 3 The Bar Codes 3 programming mode contains programming parameters for Interleaved 2 of 5.

Defaults Parameter

Default Value

Interleaved 2 of 5

Disable

Bar Code Length

Range Check

Value 1

04

Value 2

16

Check Digit Present

Disable

Transmit Check Digit

Disable

Specific Program Parameters Interleaved 2 of 5 The Interleaved 2 of 5 parameter controls reading Interleaved 2 of 5 bar codes. Disable reading Interleaved 2 of 5 bar codes by scanning the Hex 0 tag and enable reading by scanning the Hex 1 tag. The default is to disable reading. If you choose to disable reading Interleaved 2 of 5 bar codes, there are no other entries allowed for this parameter. However, if you enable reading Interleaved 2 of 5 bar codes, you can program the remaining parameters.

Page 145

Chapter 7: Programming

7-29

Bar Code Length The Bar Code Length parameter selects the method for determining if an Interleaved 2 of 5 bar code is a valid length. The Range Check method identifies a length range by specifying the minimum and maximum number of characters. The Specific Check method identifies two specific bar code lengths by specifying the number of characters in each. With this option, the number of characters in all Interleaved 2 of 5 bar codes must be one of the two numbers. Scan the Hex 0 tag to use the Range Check method, scan the Hex 1 tag to use the Specific Check method. The default is the Range Check method. Value 1 and 2 The Value 1 and Value 2 parameter specifies the valid Interleaved 2 of 5 bar code lengths. Use this option with the Bar Code Length parameter option described in Bar Code Length. If you select the Range Check method, Value 1 specifies the minimum number of characters in a valid Interleaved 2 of 5 bar code and Value 2 specifies the maximum number of characters. If you select the Specific Check method, Value 1 contains one specific number of characters and Value 2 contains another. Accepted values for Value 1 and Value 2 are 4 to 38 readable characters. The number of readable characters must be an even number; if you specify an odd number, it is rounded down one. Each value is input using two Hex tags. The first can be Hex 0 through Hex 3 and the second can be Hex 0 through Hex 9. The default for Value 1 is 08 and for Value 2 is 16 Check Digit Present The Check Digit Present parameter permits you to determine if the bar code must contain a correct check digit to be identified as valid. If this function is enabled, the bar code is ignored if a check digit is not present. Scan the Hex 0 tag to disable this option, or the Hex 1 tag to enable it. Disable is the default.

Page 146

7-30

Chapter 7: Programming

Transmit Check Digit The Transmit Check Digit parameter selects whether to send the check digit to the host terminal. Scan the Hex 0 tag to disable this option, or the Hex 1 tag to enable it. The default is to disable sending the check digit.

Program Example Following is an example of a completed Bar Codes - 3 programming worksheet. In this example Interleaved 2 of 5 is programmed for the following. •

Interleaved 2 of 5 – enabled

•

Bar Code Length – range check method

•

Minimum bar code length – 4 characters

•

Maximum bar code length – 10 characters

•

Check Digit Present – enabled

•

Transmit Check Digit – enabled

Your Program

1

5

Bar Codes - 3

A

B

1

0

Interleaved Bar Code 2 of 5 Length

0 4

1 0

Value 1

Value 2

C

D

1

1

Check Digit Transmit Present Check Digit R0069