WT4070/90 Wearable Terminal Integrator Guide: Maintenance & Troubleshooting

Pages 167 to 178 of 206, from WT4070/90 Wearable Terminal Integrator Guide

The original document is the PDF (7.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Motorola WT4090

Page 167

Chapter 10 Maintenance & Troubleshooting Introduction This chapter includes instructions on cleaning and storing the wearable terminal, and provides troubleshooting solutions for potential problems during wearable terminal operating.

Maintaining the Wearable Terminal For trouble-free service, observe the following tips when using the wearable computer:

• Do not scratch the touch screen of the wearable computer. When activating with the wearable computer touch screen, use finger tips. Never use a pen or pencil or other sharp object on the surface of the screen. Zebra requires using a screen protector, p/n KT-114032-01R or KT-114032-02R.

• A screen protector is applied to the wearable computer touch screen. Zebra requires using this to minimize wear and tear. Screen protectors enhance the usability and durability of touch screen displays. Benefits include: • Protection from scratches and gouges • Durable touch surface with tactile feel • Abrasion and chemical resistance • Keeping the device’s screen looking new • Quick and easy installation.

• Protect the wearable computer with a touch screen from temperature extremes. • Do not store or use the wearable computer with a touch screen in any location that is extremely dusty, damp, or wet.

• Use a soft lens cloth to clean the wearable computer display/touch screen. • Periodically replace the rechargeable Li-ion battery to ensure maximum battery life and product performance. Battery life depends on individual usage patterns.

• The screen of the wearable computer contains glass. Take care not to drop the wearable computer or subject it to strong impact.

Page 168

10 - 2 WT4070/90 Wearable Terminal Integrator Guide

• Regularly replace all Velcro® straps on the wrist mount and wearable scanners, to ensure adequate adhesion of the Velcro.

• On touch screen versions, periodically replace the screen protector, especially if it is scratched.

Wrist Mount Cleaning Instructions It may be necessary to wash the wrist mount straps and replaceable pad when they become soiled. Remove the straps and pad from the wrist mount. Hand wash in cold water with a mild detergent (such as Woolite®). Do not use bleach. Air dry. Do not use a dryer. Replaceable Pad

Strap

Figure 10-1 Wrist Mount Soft Goods

Arm Sleeve Cleaning Instructions It may be necessary to wash the arm sleeve when it become soiled. Hand wash in cold water with a mild detergent (such as Woolite®). Do not use bleach. Air dry. Do not use a dryer.

Removing the Screen Protector NOTE

Not using a screen protector on a touch panel device can affect warranty coverage. To purchase replacement protectors, contact your local account manager or Zebra. These include screen protector installation instructions. Part number: KT-67525-01R or KT-67525-02R Screen Protector 3/pk.

A screen protector is applied to the wearable terminal with touch screen. Zebra mandates using this to minimize wear and tear. Screen protectors enhance the usability and durability of touch screen displays. To remove the screen protector, lift the corner using a thin plastic card, such as a credit card, then carefully lift it off the display.

Page 169

Maintenance & Troubleshooting 10 - 3

Lift Screen Protector Corner

Figure 10-2 Removing the Screen Protector

CAUTION

Do not use a sharp object to remove the protector. Doing so can damage the touch screen.

Battery Safety Guidelines • The area in which the units are charged should be clear of debris and combustible materials or chemicals. Particular care should be taken where the device is charged in a non commercial environment.

• Improper battery use may result in a fire, explosion, or other hazard. • To charge the mobile device battery, the battery and charger temperatures must be between 0 ºC and +40 ºC (+32 ºF and +104 ºF).

• Do not use incompatible batteries and chargers. Use of an incompatible battery or charger may present a risk of fire, explosion, leakage, or other hazard. If you have any questions about the compatibility of a battery or a charger, contact Zebra support.

• Do not disassemble or open, crush, bend or deform, puncture, or shred. • Severe impact from dropping any battery-operated device on a hard surface could cause the battery to overheat.

• Do not short circuit a battery or allow metallic or conductive objects to contact the battery terminals. • Do not modify or remanufacture, attempt to insert foreign objects into the battery, immerse or expose to water or other liquids, or expose to fire, explosion, or other hazard.

• Do not leave or store the equipment in or near areas that might get very hot, such as in a parked vehicle or near a radiator or other heat source. Do not place battery into a microwave oven or dryer.

• Battery usage by children should be supervised. • Please follow local regulations to promptly dispose of used re-chargeable batteries. • Do not dispose of batteries in fire.

Page 170

10 - 4 WT4070/90 Wearable Terminal Integrator Guide

• Seek medical advice immediately if a battery has been swallowed. • In the event of a battery leak, do not allow the liquid to come in contact with the skin or eyes. If contact has been made, wash the affected area with large amounts of water and seek medical advice.

• If you suspect damage to your equipment or battery, contact Zebra support to arrange for inspection.

Cleaning WARNING!

CAUTION

Avoid exposing this product to contact with hot oil or other flammable liquids. If such exposure occurs, unplug the device and clean the product immediately in accordance with these guidelines.

Always wear eye protection. Read warning label on compressed air and alcohol product before using. If you have to use any other solution for medical reasons please contact Zebra for more information.

Materials Required • Alcohol wipes • Soft lens cloth • Cotton tipped applicators • Isopropyl alcohol • Can of compressed air with a tube.

Cleaning the Wearable Terminal Housing Using the alcohol wipes, wipe the housing including keys and in-between keys.

Display The display can be wiped down with the alcohol wipes, but care should be taken not to allow any pooling of liquid around the edges of the display. Immediately dried the display with a soft, non-abrasive cloth to prevent streaking. For WT4090 with touch panel, only use a soft lens cloth to clean the touch panel overlay surface.

Connectors Clean all three connectors, two interface connectors on the sides of the wearable terminal and the cradle connector on the back. 1.

Remove the main battery from mobile computer. See Installing the Main Battery on page 1-4.

2.

Remove connector rubber plugs, if required.

3.

Dip the cotton portion of the cotton tipped applicator in isopropyl alcohol.

Page 171

Maintenance & Troubleshooting 10 - 5

4.

Rub the cotton portion of the cotton tipped applicator back-and-forth across each connector. Do not leave any cotton residue on the connector.

5.

Repeat at least three times.

6.

Use the cotton tipped applicator dipped in alcohol to remove any grease and dirt near the connector area.

7.

Use a dry cotton tipped applicator and repeat steps 4 through 7. CAUTION

Do not point nozzle at yourself and others, ensure the nozzle or tube is away from your face.

8.

Spray compressed air on the connector areas by pointing the tube/nozzle about ½ inch away from the surface.

9.

Inspect the area for any grease or dirt, repeat if required.

10. Replace connector rubber plugs, if required.

Cleaning the RS309, RS409 and RS507 Housing Using the alcohol wipes, wipe the housing including keys and in-between keys.

Scanner Exit Window Wipe the scanner exit window periodically with a lens cloth or other material suitable for cleaning optical material such as eyeglasses.

Connectors 1.

Disconnect the scanner from mobile computer.

2.

Dip the cotton portion of the cotton tipped applicator in isopropyl alcohol.

3.

Rub the cotton portion of the cotton tipped applicator back-and-forth across the connector pins. Do not leave any cotton residue on the connector.

4.

Repeat at least three times.

5.

Use the cotton tipped applicator dipped in alcohol to remove any grease and dirt near the connector area.

Use a dry cotton tipped applicator and repeat steps 3 through 5. CAUTION

Do not point nozzle at yourself and others, ensure the nozzle or tube is away from your face.

6.

Spray compressed air on the connector area by pointing the tube/nozzle about ½ inch away from the surface.

7.

Inspect the area for any grease or dirt, repeat if required.

Cleaning Cradle Connectors To clean the connectors on a cradle: 1.

Remove the DC power cable from the cradle.

2.

Dip the cotton portion of the cotton tipped applicator in isopropyl alcohol.

Page 172

10 - 6 WT4070/90 Wearable Terminal Integrator Guide

3.

Rub the cotton portion of the cotton tipped applicator along the pins of the connector. Slowly move the applicator back-and-forth from one side of the connector to the other. Do not let any cotton residue on the connector.

4.

All sides of the connector should also be rubbed with the cotton tipped applicator. CAUTION

Do not point nozzle at yourself and others, ensure the nozzle or tube is away from your face.

5.

Spray compressed air in the connector area by pointing the tube/nozzle about ½ inch away from the surface.

6.

Ensure that there is no lint left by the cotton tipped applicator, remove lint if found.

7.

If grease and other dirt can be found on other areas of the cradle, use lint free cloth and alcohol to remove. 8.

Allow at least 10 to 30 minutes (depending on ambient temperature and humidity) for the alcohol to air dry before applying power to cradle. If the temperature is low and humidity is high, longer drying time is required. Warm temperature and dry humidity requires less drying time.

Cleaning Frequency The cleaning frequency is up to the customer’s discretion due to the varied environments in which the mobile devices are used. They may be cleaned as frequently as required. However when used in dirty environments it may be advisable to periodically clean the ring scanners’ exit windows to ensure optimum scanning performance.

Troubleshooting Wearable Terminal Table 10-1 Troubleshooting the Wearable Terminal

Problem

Cause

Solution

Wearable terminal does not turn on.

Lithium-ion battery not charged.

Charge or replace the lithium-ion battery in the wearable terminal.

Lithium-ion battery not installed properly.

Ensure battery is installed properly. See Installing and Removing the Main Battery on page 1-4.

System crash.

Perform a warm boot. If the wearable terminal still does not turn on, perform a cold boot. See Resetting the Wearable Terminal on page 1-8.

Page 173

Maintenance & Troubleshooting 10 - 7

Table 10-1 Troubleshooting the Wearable Terminal (Continued)

Problem Rechargeable lithium-ion battery did not charge.

Cause

Solution

Battery failed.

Replace battery. If the wearable terminal still does not operate, try a warm boot, then a cold boot. See Resetting the Wearable Terminal on page 1-8.

Wearable terminal removed from cradle while battery was charging.

Insert wearable terminal in cradle and begin charging.

Ambient temperature of the cradle is too warm or too cold.

Move the cradle to an area where the ambient temperature is between 0 °C and 40 °C (32 °F and 104 °F).

Cannot see characters on display (not applicable to voice only configuration).

Wearable terminal not powered on.

Press the Power button.

Display on touch panel version is hard to read (not applicable to voice only configuration).

Screen protector may be scratched or worn.

Replace screen protector.

During data communication, no data was transmitted, or transmitted data was incomplete.

Wearable terminal removed from cradle or unplugged from host computer during communication.

Replace the wearable terminal in the cradle, or reattach the Synchronization cable and re-transmit.

Incorrect cable configuration.

See the System Administrator.

Communication software was incorrectly installed or configured.

Perform setup. See Chapter 2, Accessories for details. Ensure that Microsoft ActiveSync 4.1 or greater is installed on the host computer.

Volume setting is low or turned off.

Adjust volume. Change volume settings by selecting Start > Settings > Control Panel > Volume & Sounds icon > Volume tab.

No sound is audible.

Move the slider to change the volume level or use volume control on voice application.

Page 174

10 - 8 WT4070/90 Wearable Terminal Integrator Guide

Table 10-1 Troubleshooting the Wearable Terminal (Continued)

Problem

Cause

Solution

Wearable terminal turns itself off.

Wearable terminal is inactive.

The wearable terminal turns off after a period of inactivity. If the wearable terminal is running on battery power, this period can be set to 30 sec., 1, 2, 3, 4, 5 or 6 minutes. If the wearable terminal is running on external power, this period can be set to 1, 2, 3, 5, 10, 15 and 30 minutes. Check the power settings by selecting Start > Settings > Control Panel > Power icon > Power Off tab. Change the setting if you need a longer delay before the automatic shutoff feature activates.

Voice Only WT4090 was set to suspend.

Return Voice Only WT4090 suspend setting to factory default (disabled).

Battery is depleted.

Replace or recharge the battery.

Battery is not inserted properly.

Insert the battery properly (see Installing and Removing the Main Battery on page 1-4).

The wearable computer’s battery is low and it powers down to protect memory content.

Replace or recharge the battery.

Too many files stored on the wearable terminal.

Delete unused memos and records. You can save these records on the host computer.

Too many applications installed on the wearable terminal.

If you have installed additional applications on the wearable terminal, remove them to recover memory. Select Start > Settings > Control Panel > Remove Programs icon. Select the unused program and select Remove.

A message appears stating that the wearable terminal memory is full. (not applicable to voice only configuration).

Page 175

Maintenance & Troubleshooting 10 - 9

Table 10-1 Troubleshooting the Wearable Terminal (Continued)

Problem

Cause

Solution

The wearable terminal does not accept scan input.

Scanning application is not loaded.

Verify that the unit is loaded with a scanning application. See the System Administrator.

Unreadable bar code.

Ensure the symbol is not defaced.

Distance between exit window and bar code is incorrect.

Ensure wearable terminal is within proper scanning range.

Wearable terminal is not programmed for the bar code.

Ensure the wearable terminal is programmed to accept the type of bar code being scanned.

Wearable terminal is not programmed to generate a beep.

If a beep on a good decode is expected and a beep is not heard, check that the application is set to generate a beep on good decode.

Battery is low.

If the scanner stops emitting a laser beam when the trigger is pressed, check the battery level. When the battery is low, the scanner shuts off before the wearable terminal low battery condition notification. Note: If the scanner is still not reading symbols, contact the distributor or Zebra.

Headset adapter without a headset is connected to the wearable terminal during a cold boot.

Disconnect the headset adapter prior to performing a cold boot.

Scanner trigger is held down during a cold boot.

Do not press trigger during a cold boot.

P1 or P2 key is held down during a cold boot.

Do not press the P1 or P2 key during a cold boot.

If all three LEDs are lit solid.

Voice Only WT4090 is in IPL mode.

Perform cold boot. See Resetting the Wearable Terminal on page 1-8.

WLAN connection is lost when the wearable terminal is connected to a host computer using ActiveSync.

Microsoft security feature prevents connection to two separate networks.

Disconnect from the WLAN network prior to connecting to a host computer using ActiveSync.

Wearable terminal goes into IPL mode after cold boot.

Page 176

10 - 10 WT4070/90 Wearable Terminal Integrator Guide

Four Slot Spare Battery Charger Table 10-2 Troubleshooting The Four Slot Spare Battery Charger

Symptom Batteries not charging.

Possible Cause

Solution

Battery was removed from the charger or charger was unplugged from AC power too soon.

Re-insert the battery in the charger or re-connect the charger’s power supply.

Battery is faulty.

Verify that other batteries charge properly. If so, replace the faulty battery.

Battery contacts not connected to charger.

Verify that the battery is seated in the battery well correctly with the contacts facing down.

Ambient temperature of the charger is too warm or too cold.

Move the charger to an area where the ambient temperature is between 0 °C and 40 °C.

Four Slot Ethernet Cradle Table 10-3 Troubleshooting the Four Slot Ethernet Cradle

Problem

Cause

Solution

Wearable terminal amber Charge Status LED does not light when wearable terminal inserted.

Cradle is not receiving power.

Ensure the power cable is connected securely to both the cradle and to AC power.

Wearable terminal is not correctly seated.

Remove and re-insert the wearable terminal into the cradle, ensuring it is correctly seated.

Wearable terminal battery is not charging.

Wearable terminal was removed from cradle or cradle was unplugged from AC power too soon.

Ensure cradle is receiving power. Ensure the wearable terminal is seated correctly.

Battery is faulty.

Verify that other batteries charge properly. If so, replace the faulty battery.

The wearable terminal is not fully seated in the cradle.

Remove and re-insert the wearable terminal into the cradle, ensuring it is correctly seated.

Ambient temperature of the cradle is too warm or too cold.

Move the cradle to an area where the ambient temperature is between 0 °C and 40 °C (32 °F and 104 °F).

Page 177

Maintenance & Troubleshooting 10 - 11

Table 10-3 Troubleshooting the Four Slot Ethernet Cradle (Continued)

Problem

Cause

During data communication, no data was transmitted, or transmitted data was incomplete.

Solution

Wearable terminal removed from cradle during communication.

Replace wearable terminal in cradle and retransmit.

Incorrect cable configuration.

See the system administrator.

Ethernet connection error. Link LED is not lit (see Link LED on page 2-10).

See the system administrator. Probable Ethernet connection error.

Single Slot USB Cradle Table 10-4 Troubleshooting the Single Slot USB Cradle

Symptom

Possible Cause

LEDs do not light when wearable terminal or spare battery is inserted.

Cradle is not receiving power.

Ensure the power cable is connected securely to both the cradle and to AC power.

Wearable terminal is not seated firmly in the cradle.

Remove and re-insert the wearable terminal into the cradle, ensuring it is firmly seated.

Spare battery is not seated firmly in the cradle.

Remove and re-insert the spare battery into the charging slot, ensuring it is firmly seated.

Wearable terminal was removed from cradle or cradle was unplugged from AC power too soon.

Ensure cradle is receiving power. Ensure wearable terminal is seated correctly. Confirm main battery is charging. View battery status by selecting Start > Settings > Control Panel > Power icon.

Battery is faulty.

Verify that other batteries charge properly. If so, replace the faulty battery.

The wearable terminal is not fully seated in the cradle.

Remove and re-insert the wearable terminal into the cradle, ensuring it is firmly seated.

Ambient temperature of the cradle is too warm or too cold.

Move the cradle to an area where the ambient temperature is between 0 °C and 40 °C (32 °F and 104 °F).

Battery not fully seated in charging slot.

Remove and re-insert the spare battery into the cradle, ensuring it is firmly seated.

Battery inserted incorrectly.

Ensure the contacts are facing down and toward the back of the cradle.

Battery is faulty.

Verify that other batteries charge properly. If so, replace the faulty battery.

Wearable terminal battery is not charging.

Spare battery is not charging.

Action

Page 178

10 - 12 WT4070/90 Wearable Terminal Integrator Guide

Table 10-4 Troubleshooting the Single Slot USB Cradle (Continued)

Symptom

Possible Cause

During data communications, no data was transmitted, or transmitted data was incomplete.

Wearable terminal removed from cradle during communications.

Replace wearable terminal in cradle and retransmit.

Incorrect cable configuration.

See the System Administrator.

Communications software is not installed or configured properly.

Perform setup as described in Chapter 2, Accessories.

Cannot ActiveSync with Host Computer

Action

Ensure that Microsoft ActiveSync 4.1 or greater is installed on the host computer.

Wrong USB cable used.

Ensure that the cable has a USB A connector on one end and a USB mini B connector on the other end.

Host computer not configured properly.

Ensure that ActiveSync on the host computer is set to allow USB connections.

The wearable computer is not fully seated in the cradle.

Remove and re-insert the wearable computer into the cradle, ensuring it is firmly seated.