Page 97

Wireless Applications 5 - 31

• ICMP Ping - tests the wireless network connection. • Trace Route - tests a connection at the network layer between the wearable terminal and any place on the network.

• Known APs - displays the APs in range using the same ESSID as the wearable terminal. • Quit - Exits the Wireless Diagnostics window. To return to the Wireless Diagnostics window from an option window, press ESC.

ICMP Ping Window The ICMP Ping window allows testing a connection at the network layer (part of the IP protocol) between the wearable terminal and an AP. Ping tests only stop when you select the Stop Test button, close the Wireless Diagnostics application, or if the wearable terminal switches between infrastructure and ad-hoc modes. To open the ICMP Ping window, press 1.

Figure 5-40 ICMP Ping Window

To perform an ICMP ping: 1.

In the IP field, enter an IP address or select an IP address from the drop-down list.

2.

Press TAB to highlight the Size drop-down list.

3.

Using the navigation keys, select a size value.

4.

Press TAB to highlight Start Test.

5.

Press Blue - BKSP (SPACE). The ICMP Ping test starts. Information of the ping test displays in the appropriate fields.

Trace Route Window Trace Route traces a packet from a computer to a host, showing how many hops the packet requires to reach the host and how long each hop takes. The Trace Route utility identifies where the longest delays occur.

The Trace Route window allows testing a connection at the network layer (part of the IP protocol) between the wearable terminal and any place on the network. To open the Trace Route window, press 2.

Page 98

5 - 32 WT4070/90 Wearable Terminal Integrator Guide

Figure 5-41 Trace Route Window

Enter an IP address or a DNS Name in the IP combo box. Press TAB to highlight Start Test. Press Blue - BKSP. The IP combo box should match the information shown in the ICMP Ping window’s IP combo box. When starting a test, the trace route attempts to find all routers between the wearable terminal and the destination. The Round Trip Time (RTT) between the wearable terminal and each router appears, along with the total test time. The total test time may be longer than all RTTs added together because it does not only include time on the network.

Known APs Window The Known APs window displays the APs in range using the same ESSID as the wearable terminal. This window is only available in Infrastructure mode. To open the Known APs window, press 3.

Figure 5-42 Known APs Window

See Table 5-22 for the definitions of the icons next to the AP. Table 5-22 Current Profile Window

Icon

Description Indicates that the AP is the associated access point, and is set to mandatory. Indicates that the AP is the associated access point, but is not set to mandatory. Indicates that the wearable terminal is not associated to this AP, but the AP is set as mandatory. Indicates that the wearable terminal is not associated to this AP, and AP is not set as mandatory.

Using the navigation keys select an AP. Press Blue key - TAB (Menu) to display a pop-up menu with the following options: Set Mandatory and Set Roaming. Select Set Mandatory to prohibit the wearable terminal from associating with a different AP. The letter M displays on top of the icon. The wearable terminal connects to the selected AP and never roams until:

• You select Set Roaming

Page 99

Wireless Applications 5 - 33

• The wearable terminal roams to a new profile • The wearable terminal suspends • The wearable terminal resets (warm or cold). Select Set Roaming to allow the wearable terminal to roam to any AP with a better signal. These settings are temporary and never saved to the registry. Select Refresh to update the list of the APs with the same ESSID. The highest signal strength value is 32.

Options Use the wireless Option dialog box to select one of the following operation options from the drop-down list:

• Operating Mode Filtering • Regulatory • Band Selection • System Options • Change Password • Export. To open the Options window, press ALT - w, select Options using the navigation keys and press ENTER.

Operating Mode Filtering The Operating Mode Filtering options cause the Find WLANs application to filter the available networks found.

Figure 5-43 OP Mode Filtering Dialog Box

Page 100

5 - 34 WT4070/90 Wearable Terminal Integrator Guide

The AP Networks and Ad-Hoc Networks check boxes are selected by default. To select/de-select the checkboxes, press TAB to highlight a checkbox. Press Blue - BKSP to select or de-select the checkbox. Table 5-23 OP Mode Filtering Options

Field

Description

AP Networks

Select the AP Networks check box to display available AP networks and their signal strength within the Available WLAN Networks (see Find WLANs Application on page 4-5). These are the APs available to the wearable terminal profile for association. If this option was previously disabled, refresh the Available WLAN Networks window to display the AP networks available to the wearable terminal.

AD-Hoc Networks

Select the Ad-Hoc Networks check box to display available peer (adapter) networks and their signal strength within the Available WLAN Networks. These are peer networks available to the wearable terminal profile for association. If this option was previously disabled, refresh the Available WLAN Networks window to display the Ad Hoc networks available to the wearable terminal.

Press TAB to highlight Save and then press ENTER to save the settings or press ESC to discard any changes. Press ESC to exit the Options dialog box.

Regulatory Options Use the Regulatory settings to configure the country the wearable terminal is in. Due to regulatory requirements (within a country) a wearable terminal is only allowed to use certain channels.

Figure 5-44 Regulatory Options Dialog Box Table 5-24 Regulatory Options

Field

Description

Settings

Select the country from the drop-down list. To connect to a profile, the profile country must match this setting, or the AP country setting if you select the Enable 802.11d check box.

Enable 802.11d

If you enable this setting the WLAN adapter attempts to retrieve the country setting from the APs. Profiles which use Infrastructure mode can only connect if this country setting is the same as the AP country setting or if the profile country setting is set to Allow Any Country. All APs must be configured to transmit the country information.

1.

Press TAB to highlight the Settings drop-down menu. Use the scroll keys to select a country from the list.

2.

Press TAB to highlight the Enable 802.11d checkbox. Press Blue - BKSP to enable or disable the check box.

3.

Press TAB to highlight Save and then press ENTER to save the settings or press ESC to discard any changes.

4.

Press ESC to exit the Options dialog box.

Page 101

Wireless Applications 5 - 35

Band Selection The Band Selection settings identify the frequency bands to scan when finding WLANs. These values refer to the 802.11 standard networks. NOTE

Select one band for faster access when scanning for WLANs.

Figure 5-45 Band Selection Dialog Box Table 5-25 Band Selection Options

Field

Description

2.4GHz Band

The Find WLANs application list includes all networks found in the 2.4 GHz band (802.11b and 802.11g).

5GHz Band

The Find WLANs application list includes all networks found in the 5 GHz band (802.11a).

1.

Press TAB to highlight the 2.4 GHz Band check box. Press Blue - BKSP to enable or disable the check box.

2.

Press TAB to highlight the 5 GHz Band check box. Press Blue - BKSP to enable or disable the check box.

3.

Press TAB to highlight Save and then press ENTER to save the settings or press ESC to discard any changes.

4.

Press ESC to exit the Options dialog box.

System Options Use System Options to set miscellaneous system setting.

Figure 5-46 System Options Dialog Box

Page 102

5 - 36 WT4070/90 Wearable Terminal Integrator Guide

Table 5-26 System Options

Field

Description

Profile Roaming

Configures the wearable terminal to roam to the next available WLAN profile when it moves out of range of the current WLAN profile.

Enable IP Mgmt

Enables the Wireless Companion Services to handle IP address management. The Wireless Companion Service configures the IP based on what is configured in the network profile. Deselect this to manually configure the IP in the standard Windows IP window. Enabled by default.

Auto Time Config

Enables automatic update of the system time. Network association updates the device time based on the time set in the AP. This proprietary feature is only supported with Zebra infrastructure. Enabled by default.

1.

Press TAB to highlight the Profile Roaming check box. Press Blue - BKSP to enable or disable the check box.

2.

Press TAB to highlight the Enable IP Mgmt check box. Press Blue - BKSP to enable or disable the check box.

3.

Press TAB to highlight the Auto Time Config check box. Press Blue - BKSP to enable or disable the check box.

4.

Press TAB to highlight Save and then press ENTER to save the settings or press ESC to discard any changes.

5.

Press ESC to exit the Options dialog box.

Change Password Use Change Password to require a password before editing a profile. This allows pre-configuring profiles and prevents users from changing the network settings. The user can use this feature to protect settings from a guest user. By default, the password is not set.

Figure 5-47 Change Password Window

To create a password for the first time, enter the new password in the New: and Confirm: text boxes. Select Save. The Current: text box does not appear if a password was not previously set. To change an existing password, enter the current password in the Current: text box and enter the new password in the New: and Confirm: text boxes. Select Save. To delete the password, enter the current password in the Current: text box and leave the New: and Confirm: text boxes empty. Select Save. NOTE

Passwords are case sensitive and can not exceed 160 characters.

Page 103

Wireless Applications 5 - 37

Export NOTE

Exporting options enables settings to persists after cold boot.

Use Export to export all profiles to a registry file, and to export the options to a registry file.

Figure 5-48 Options - Export Dialog Box

To export options: 1.

Select Export Options and press Blue - BKSP. The Save As dialog box displays.

Figure 5-49 Export Options Save As Dialog Box 2.

Enter a filename in the Name: field. The default filename is WCS_OPTIONS.REG.

3.

Select Save and press ALT- BKSP.

To export all profiles: 1.

Select Export All Profiles and press ALT- BKSP. The Save As dialog box displays.

Figure 5-50 Export All Profiles Save As Dialog Box 2.

Enter a filename in the Name: field. The default filename is WCS_PROFILES.REG.

3.

In the Folder: drop-down list, select the desired folder.

4.

Select Save and press ALT- BKSP.

Page 104

5 - 38 WT4070/90 Wearable Terminal Integrator Guide

Selecting Export All Profiles saves the current profile. This information is used to determine which profile to connect with after a warm boot or cold boot.

Persistence Export options and profiles to provide cold boot persistence for Windows CE 5.0 devices. Save the exported registry files in the Application folder to use them on a cold boot or clean boot and restore previous profile and option settings. Currently, only server certificates can be saved for persistence. To save server certificates for persistence, save the certificate files in the folder Application to install the certificates automatically on a cold or clean boot. NOTE

User certificates cannot be saved for cold boot or clean boot persistence at this time.

Registry Settings Use a registry key to modify some of the parameters. The registry path is: HKLM\SOFTWARE\Symbol Technologies, Inc.\Configuration Editor Table 5-27 Registry Parameter Settings

Key

Type

Default

Description

CertificateDirectory

REG_SZ

\\Application

The default directory to find certificates.

EncryptionMask

REG_DWORD

0x0000001F

Defines the supported encryption types. This is a bitwise mask with each bit corresponding to an encryption type. 1 = Type is supported 0 = Type is not supported Bit Number 0 1 2 3 4

Encryption Type None 40-Bit WEP 128-Bit WEP TKIP AES (Fusion 2.5 only)

Page 105

Wireless Applications 5 - 39

Log On/Off Application When the user launches the Log On/Off application, the wearable terminal may be in two states; the user may be logged onto the wearable terminal by already entering credentials through the login box, or there are no user logged on. Each of these states have a separate set of use cases and a different look to the dialog box.

User Already Logged In If already logged into the wearable terminal, the user can launch the login dialog box for the following reasons:

• Connect to and re-enable a cancelled profile. To do this: • Launch the Log On/Off dialog. • Select the cancelled profile from the profile list. • Login to the profile. NOTE

Re-enable cancelled profiles using the Profile Editor Wizard and choosing to connect to the cancelled profile. Cancelled profiles are also re-enabled when a new user logs on.

• Log off the wearable terminal to prevent another user from accessing the current users network privileges. • Switch wearable terminal users to quickly logoff the wearable terminal and allow another user to log into the wearable terminal.

No User Logged In If no user is logged into the wearable terminal, launch the login dialog box and log in to access user profiles. The Login dialog box varies if it is:

• Launched by WCS, because the service is connecting to a new profile that needs credentials. • Launched by WCS, because the service is trying to verify the credentials due to credential caching rules. • Launched by a user, when a user is logged in. • Launched by a user, when no user is logged in. Table 5-28 Log On/Off Options

Field

Description

Wireless Profile Field

When launching the login application, the Wireless Profile field has available all the wireless profiles that require credentials. This includes profiles that use EAP TLS, PEAP, LEAP, and EAP-TTLS.

Profile Status Icon

The profile status icon (next to the profile name) shows one of the following states: The selected profile is cancelled. The selected profile is enabled but is not the current profile. The profile is the current profile (always the case for WCS Launched).

Page 106

5 - 40 WT4070/90 Wearable Terminal Integrator Guide

Table 5-28 Log On/Off Options (Continued)

Field

Description

Network Username and Password Fields

The Network Username and Network Password fields are used as credentials for the profile selected in the Wireless Profile field. Currently these fields are limited to 159 characters.

Mask Password Checkbox

The Mask Password checkbox determines whether the password field is masked (i.e., displays only the '*' character) or unmasked (i.e., displays the entered text). Check the box to unmask the password. Uncheck the box to mask the password (the default).

Status Field

The status field displays status that is important to the login dialog. If the user opens the dialog and needs to prompt for credentials for a particular profile at this time, it can use the status field to let the user know that the network is held up by the password dialog being open.

Selecting OK sends the credentials though WCS API. If there are no credentials entered, a dialog box displays informing the user which field was not entered. The Log Off button only displays when a user is already logged on. When the Log Off button is selected, the user is prompted with three options: Log Off, Switch Users, and Cancel. Switching users logs off the current user and re-initialize the login dialog box to be displayed for when there is no user logged on. Logging off logs off the current user and close the login dialog box. Cancel closes the Log Off dialog box and the Login dialog box displays. When the user is logged off, the wearable terminal only roams to profiles that do not require credentials or to profiles that were created with the credentials entered into the profile. The Cancel button closes the dialog without logging into the network. If the login dialog was launched by the WCS and not by the user, selecting Cancel first causes a message box to display a warning that the cancel disables the current profile. If the user still chooses to cancel the login at this point, the profile is cancelled. Once a profile is cancelled, the profile is terminal until a user actively re-enables it or a new user logs onto the wearable terminal.