Page 9

Quick Reference Guide

9

Resetting the Mobile Computer Warm Boot A warm boot restarts the mobile computer by closing all running programs. Press and simultaneously hold the Up Arrow and the Down Arrow keys for 10 seconds and then press the Scan key. Release the Up Arrow and the Down Arrow keys. Wait one second and then release the Scan key.

Cold Boot A cold boot restarts the mobile computer and erases all user stored records and entries that are not saved in flash memory (Application and Platform folders). Never perform a cold boot unless a warm boot does not solve the problem. Press and simultaneously hold the Up Arrow and Down Arrow keys for 10 seconds and then press and hold the Scan key. Release the Up and Down Arrow keys and continue to hold the Scan key until the display turns off. Release the Scan key.

Maintenance •

Protect the mobile computer from temperature extremes.

•

Do not store or use the mobile computer in any location that is extremely dusty, damp, or wet.

•

Use a soft lens cloth to clean the mobile computer. If the surface of the mobile computer screen becomes soiled, clean it with a soft cloth moistened with a diluted window-cleaning solution.

•

Periodically replace the rechargeable battery to ensure maximum battery life and product performance. Battery life depends on individual usage patterns. Refer to the MC17 Product Reference Guide for more information.

•

Take care not to scratch the bezel of the mobile computer. Replacement standard and custom Bezel Kits are available, p/n KT-098273-XXR.

Bezel Replacement The plastic bezel can be replaced with a new or customer specific bezel.

Page 10

10

MC17/MC17A/MC17T Mobile Computer

1. Place the mobile computer on a desktop with the display facing down. 2. Using a T6 Torx drive, remove two screws securing the bezel to the housing. 3. Align the replacement bezel on the housing. 4. Using a T6 Torx drive, secure the bezel to the housing using the two Torx screws. 5. Torque the screws to 2.5 ± 0.2 kgf/cm (2.17 ± 0.17 in-lbs.).

Troubleshooting Problem

Cause

Mobile computer does not turn on.

Battery not charged.

Charge or replace the battery.

Battery not installed properly.

Install the battery properly. See Installing the Battery on page 4.

The system is not responding.

Perform a warm boot. If the mobile computer still does not turn on, perform a cold boot.

Mobile Computer is in a critical suspend state due to low battery.

Place the mobile computer in the Charging cradle. The mobile computer re-boots and begins charging. Depending on how depleted the battery is, the mobile computer may take up to five minutes before it turns on.

Battery failed.

Replace battery. If the mobile computer still does not operate, perform a warm boot. See Resetting the Mobile Computer on page 9.

Mobile computer removed from cradle while battery was charging.

Insert mobile computer in cradle. The battery fully charges in approximately five hours.

Rechargeable battery did not charge.

Solution

Page 11

Quick Reference Guide Problem Mobile computer shuts off.

The mobile computer does not accept scan input.

11

Cause

Solution

Battery is depleted.

Recharge the battery.

Battery is not connected properly.

Connect the battery properly. See Installing the Battery on page 4.

The system is not responding.

Warm boot the mobile computer.

Scanning application is not loaded.

Launch a scanning application on the mobile computer. See the system administrator.

Unreadable bar code.

Ensure the symbol is not defaced.

Distance between exit window and bar code is incorrect.

Position the mobile computer within proper scanning range.

Mobile computer is not programmed for the bar code.

Program the mobile computer to accept the type of bar code being scanned. Ensure that the bar code parameters are set properly for the bar code being scanned.

Ergonomic Recommendations CAUTION In order to avoid or minimize the potential risk of ergonomic injury follow the recommendations below. Consult with your local Health & Safety Manager to ensure that you are adhering to your company’s safety programs to prevent employee injury.

• • • • • • • • • • •

Reduce or eliminate repetitive motion Maintain a natural position Reduce or eliminate excessive force Keep objects that are used frequently within easy reach Perform tasks at correct heights Reduce or eliminate vibration Reduce or eliminate direct pressure Provide adjustable workstations Provide adequate clearance Provide a suitable working environment Improve work procedures.

Regulatory Information This guide applies to the following model numbers: MC1770, MC1790.

Page 12

12

MC17/MC17A/MC17T Mobile Computer

All Motorola devices are designed to be compliant with rules and regulations in locations they are sold and will be labeled as required. Local language translations are available at the following web site: http://www.motorola.com/enterprisemobility/manuals. This device is approved under the Symbol Technologies brand; Symbol Technologies, Inc., is the Enterprise Mobility business of Motorola, Inc. (“Motorola”). Any changes or modifications to Motorola equipment, not expressly approved by Motorola, could void the user's authority to operate the equipment. CAUTION Only use Motorola approved and UL Listed accessories, battery packs and battery chargers. Do NOT attempt to charge damp/wet mobile computers or batteries. All components must be dry before connecting to an external power source.

Radio Modules The device contain approved radio module(s). These module(s) are identified below. •

WLAN SDIO Radio Module, Model: 21-92955.

Wireless Device Country Approvals Regulatory markings, subject to certification, are applied to the device signifying the radio(s) are approved for use in the following countries: United States, Canada, Japan, China, S. Korea, Australia and Europe 1. Please refer to the Motorola Declaration of Conformity (DoC) for details of other country markings. This is available at http://www2.symbol.com/doc/. Note1: For 2.4GHz Products: Europe includes, Austria, Belgium, Bulgaria, Czech Republic, Cyprus, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovak Republic, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Operation of the device without regulatory approval is illegal.

Page 13

Quick Reference Guide

13

Country Roaming This device incorporates the International Roaming feature (IEEE802.11d) which will ensure the product operates on the correct channels for the particular country of use.

Ad-hoc Operation Ad-Hoc operation is limited to Channels 36-48 (5150-5250 MHz). Use of this band is restricted to Indoor Use Only, any other use will make the operation of this device illegal.

Frequency of Operation - FCC and IC 5 GHz Only The use in the UNII (Unlicensed National Information Infrastructure) band 1 5150-5250 MHz band is restricted to Indoor Use Only; any other use will make the operation of this device illegal. 2.4 GHz Only The available channels for 802.11 b/g operation in the US are Channels 1 to 11. The range of channels is limited by firmware.

Warnings for Use of Wireless Devices Please observe all warning notices with regard to the usage of wireless devices.

Pacemakers Pacemaker manufacturers recommended that a minimum of 15 cm (6 inches) be maintained between a handheld wireless device and a pacemaker to avoid potential interference with the pacemaker. These recommendations are consistent with independent research and recommendations by Wireless Technology Research.

Persons with Pacemakers • • •

Should ALWAYS keep the device more than 15 cm (6 inches) from their pacemaker when turned ON Should not carry the device in a breast pocket Should use the ear furthest from the pacemaker to minimize the potential for interference.

Page 14

14 •

MC17/MC17A/MC17T Mobile Computer If you have any reason to suspect that interference is taking place, turn OFF your device.

Other Medical Devices Please consult your physician or the manufacturer of the medical device, to determine if the operation of your wireless product may interfere with the medical device.

RF Exposure Guidelines Safety Information Reducing RF Exposure - Use Properly Only operate the device in accordance with the instructions supplied.

International The device complies with Internationally recognized standards covering human exposure to electromagnetic fields from radio devices.

EU Handheld Devices To comply with EU RF exposure requirements, this device must be operated in the hand with a minimum separation distance of 20 cm or more from a person’s body. Other operating configurations should be avoided.

US and Canada Co-located statement To comply with FCC RF exposure compliance requirement, the antenna used for this transmitter must not be co-located or operating in conjunction with any other transmitter/antenna except those already approved in this filling.

Handheld Devices (that cannot be body worn in a belt clip/holster) To comply with FCC RF exposure requirements, this device must be operated in the hand with a minimum separation distance of 20 cm or more from a person's body. Other operating configurations should be avoided.

Laser Devices Complies with 21CFR1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated July

Page 15

Quick Reference Guide

15

26, 2001, and with EN60825-1:1994+A1:2002+A2:2001 and IEC60825-1:1993+A1:1997+A2:2001. The laser classification is marked on one of the labels on the device. Class 1 Laser devices are not considered to be hazardous when used for their intended purpose. The following statement is required to comply with US and international regulations: Caution: Use of controls, adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure. Class 2 laser scanners use a low power, visible light diode. As with any very bright light source, such as the sun, the user should avoid staring directly into the light beam. Momentary exposure to a Class 2 laser is not known to be harmful.

Scanner Labeling COMPLIES WITH 21CFR1040.10 AND 1040.11 EXCEPT FOR DEVIATIONS PURSUANT TO LASER NOTICE No. 50, DATED JULY 26, 2001, AND EN60825-1:1994+A1:2002+A2:2001, IEC60825-1:1993+A1:1997+A2:2001.

Power Supply Use only a Motorola approved power supply output rated at 12 VDC and minimum 9 A. The power supply shall be Listed to UL/CSA 60950-1; and certified to IEC60950-1 and EN60950-1 with SELV outputs. Use of alternative power supply will invalidate any approval given to this device and may be dangerous.

Taiwan - Recycling EPA (Environmental Protection Administration) requires dry battery producing or importing firms in accordance with Article 15 of the Waste Disposal Act are required to indicate the recycling marks on the batteries used in sales, giveaway or promotion. Contact a qualified Taiwanese recycler for proper battery disposal.

Page 16

16

MC17/MC17A/MC17T Mobile Computer

Radio Frequency Interference Requirements-FCC Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • • • •

Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio/TV technician for help.

Radio Transmitters (Part 15) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Radio Frequency Interference Requirements - Canada This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

Radio Transmitters This device complies with RSS 210 of Industry & Science Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.