The text of a manual · part 29 of 35
DS9208-1D Digital Scanner Product Reference Guide: Standard Default Parameters
Pages 227 to 234 of 276, from DS9208-1D Digital Scanner Product Reference Guide
The original document is the PDF (6.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Motorola DS-9208
Page 227
APPENDIX A STANDARD DEFAULT PARAMETERS Table A-1
Standard Default Parameters Table Parameter
Parameter Number
Default
Page Number
User Preferences Set Default Parameter
Set Defaults
4-4
Parameter Bar Code Scanning
ECh
Enable
4-5
Beep After Good Decode
38h
Enable
4-5
Beeper Tone
91h
Medium
4-6
Beeper Volume
8Ch
High
4-7
Volume Adjustment Trigger Timeout
F0h 93h
5.0 Sec
4-8
Beeper Duration
F1h 74h
Medium
4-9
Suppress Power-up Beeps
F1h D1h
Do not suppress
4-9
Low Power Mode
80h
Disable
4-10
Time Delay to Low Power Mode
92h
1 Hour
4-11
Trigger Mode
8Ah
Presentation
4-13
Trigger Aiming Pattern
F0h 32h
Enable
4-14
Presentation Aiming Pattern
F1h 4Eh
Disable
4-15
Momentary Trigger Mode Timeout
EDh
5 sec
4-16
Motion Detect Range
F2h 3Bh
Full
4-17
Decoding Illumination (Hand-Held Mode Only)
F0h, 2Ah
Enable
4-18
1
User selection is required to configure this interface and this is the most common selection.
Page 228
A-2
DS9208-1D Product Reference Guide
Table A-1
Standard Default Parameters Table (Continued) Parameter
Parameter Number
Default
Page Number
Post Decode Illumination
F2h 29h
Always Off
4-18
Illumination Always On (Presentation Mode Only)
F2h 59h
Illumination Automatically Controlled
4-19
Presentation Mode Field of View
F1h 61h
Full
4-20
Picklist Mode
F0h 92h
Enabled in Trigger Mode
4-21
Continuous Bar Code Read
F1h 89h
Disable
4-22
Unique Bar Code Reporting
F1h D31h
Disable
4-22
Decode Session Timeout
88h
9.9 Sec
4-23
Timeout Between Decodes, Same Symbol
89h
0.3 Sec
4-23
Timeout Between Decodes, Different Symbols
90h
0.2 Sec
4-24
Fuzzy 1D Processing
F1h 02h
Enable
4-24
Motion Tolerance (Hand-Held Trigger Modes Only)
F2h 5Ah
Less Motion Tolerance
4-25
Transmit Code ID Character
2Dh
None
4-26
Prefix Value
63h, 69h
7013 <CR><LF>
4-27
Suffix 1 Value Suffix 2 Value
62h 68h 64h 6Ah
7013 <CR><LF>
4-27
Scan Data Transmission Format
EBh
Data as is
4-28
FN1 Substitution Values
67h 6Dh
Set
4-29
Transmit “No Read” Message
5Eh
Disable
4-30
USB Device Type
HID Keyboard Emulation
5-4
Symbol Native API (SNAPI) Status Handshaking
Enable
5-5
USB Country Keyboard Types (Country Codes)
North American
5-6
USB Keystroke Delay
No Delay
5-8
Simulated Caps Lock
Disable
5-9
USB CAPS Lock Override
Disable
5-9
USB Ignore Unknown Characters
Enable
5-10
Miscellaneous Options
USB Host Parameters
1User selection is required to configure this interface and this is the most common selection.
Page 229
Standard Default Parameters
Table A-1
A-3
Standard Default Parameters Table (Continued) Parameter
Parameter Number
Default
Page Number
USB Convert Unknown to Code 39
Disable
5-10
USB Ignore Beep Directive
Honor
5-11
USB Ignore Type Directive
Honor
5-11
Emulate Keypad
Disable
5-12
Emulate Keypad with Leading Zero
Disable
5-12
USB Keyboard FN1 Substitution
Disable
5-13
Function Key Mapping
Disable
5-13
Convert Case
No Case Conversion
5-14
USB Static CDC
Enable
5-14
USB Polling Interval
8 msec
5-15
Quick Keypad Emulation
Disable
5-17
Fast HID Keyboard Emulation
Disable
5-17
IBM Specification Version
Original Specification
5-18
RS-232 Host Types
Standard1
6-6
Baud Rate
9600
6-8
Parity Type
None
6-9
Stop Bits
1
6-10
Data Bits
8-bit
6-10
Check Receive Errors
Enable
6-11
Hardware Handshaking
None
6-11
Software Handshaking
None
6-13
Host Serial Response Timeout
2 Sec
6-15
RTS Line State
Low RTS
6-16
Beep on <BEL>
Disable
6-16
Intercharacter Delay
0 msec
6-17
Nixdorf Beep/LED Options
Normal Operation
6-18
Ignore Unknown Characters
Send Bar Code
6-18
RS-232 Host Parameters
1User selection is required to configure this interface and this is the most common selection.
Page 230
A-4
DS9208-1D Product Reference Guide
Table A-1
Standard Default Parameters Table (Continued) Parameter
Parameter Number
Default
Page Number
IBM 468X/469X Host Parameters Port Address
None Selected
7-4
Convert Unknown to Code 39
Disable
7-5
Ignore Beep Directive
Honor
7-5
Ignore Configuration Directive
Honor
7-6
Keyboard Wedge Host Type
IBM PC/AT& IBM PC Compatibles1
8-4
Country Types (Country Codes)
North American
8-5
Ignore Unknown Characters
Transmit
8-7
Keystroke Delay
No Delay
8-7
Intra-Keystroke Delay
Disable
8-8
Alternate Numeric Keypad Emulation
Disable
8-8
Simulated Caps Lock
Disable
8-9
Caps Lock Override
Disable
8-9
Convert Wedge Data
No Convert
8-10
Function Key Mapping
Disable
8-10
FN1 Substitution
Disable
8-11
Send and Make Break
Send
8-11
Keyboard Wedge Host Parameters
Symbology Parameters Disable All Code Types
9-6
UPC/EAN UPC-A
01h
Enable
9-7
UPC-E
02h
Enable
9-7
UPC-E1
0Ch
Disable
9-8
EAN-8/JAN 8
04h
Enable
9-8
EAN-13/JAN 13
03h
Enable
9-9
Bookland EAN
53h
Disable
9-9
Bookland ISBN Format
F1h 40h
ISBN-10
9-10
1
User selection is required to configure this interface and this is the most common selection.
Page 231
Standard Default Parameters
Table A-1
A-5
Standard Default Parameters Table (Continued) Parameter
Decode UPC/EAN/JAN Supplementals (2 and 5 digits)
Parameter Number 10h
Default Ignore
Page Number 9-11
User-Programmable Supplementals Supplemental 1: Supplemental 2:
F1h 43h F1h 44h
9-14
UPC/EAN/JAN Supplemental Redundancy
50h
10
9-14
Decode UPC/EAN/JAN Supplemental AIM ID
F1h A0h
Combined
9-15
Transmit UPC-A Check Digit
28h
Enable
9-16
Transmit UPC-E Check Digit
29h
Enable
9-16
Transmit UPC-E1 Check Digit
2Ah
Enable
9-17
UPC-A Preamble
22h
System Character
9-17
UPC-E Preamble
23h
System Character
9-18
UPC-E1 Preamble
24h
System Character
9-19
Convert UPC-E to A
25h
Disable
9-20
Convert UPC-E1 to A
26h
Disable
9-20
EAN-8/JAN-8 Extend
27h
Disable
9-21
UCC Coupon Extended Code
55h
Disable
9-21
Coupon Report
F1h DAh
New Coupon Symbols
9-22
ISSN EAN
F1h 69h
Enable
9-23
Code 128
08h
Enable
9-24
Set Length(s) for Code 128
D1h, D2h
Any Length
9-24
GS1-128
0Eh
Enable
9-25
ISBT 128
54h
Enable
9-26
ISBT Concatenation
F1h 41h
Disable
9-27
Check ISBT Table
F1h 42h
Enable
9-28
ISBT Concatenation Redundancy
DFh
10
9-28
Code 128
1
User selection is required to configure this interface and this is the most common selection.
Page 232
A-6
DS9208-1D Product Reference Guide
Table A-1
Standard Default Parameters Table (Continued) Parameter
Parameter Number
Default
Page Number
Code 39 Code 39
00h
Enable
9-29
Trioptic Code 39
0Dh
Disable
9-29
Convert Code 39 to Code 32 (Italian Pharmacy Code)
56h
Disable
9-30
Code 32 Prefix
E7h
Disable
9-30
Set Length(s) for Code 39
12h, 13h
2 to 55
9-31
Code 39 Check Digit Verification
30h
Disable
9-32
Transmit Code 39 Check Digit
2Bh
Disable
9-32
Code 39 Full ASCII Conversion
11h
Disable
9-33
Code 39 Buffering
71h
Disable
9-34
Clear Buffer
9-35
Transmit Buffer
9-35
Code 93 Code 93
09h
Disable
9-36
Set Length(s) for Code 93
1Ah, 1Bh
4 to 55
9-36
Code 11
0Ah
Disable
9-38
Set Lengths for Code 11
1Ch, 1Dh
4 to 55
9-38
Code 11 Check Digit Verification
34h
Disable
9-40
Transmit Code 11 Check Digit(s)
2Fh
Disable
9-41
Interleaved 2 of 5 (ITF)
06h
Disable
9-41
Set Lengths for I 2 of 5
16h, 17h
14
9-41
I 2 of 5 Check Digit Verification
31h
Disable
9-44
Transmit I 2 of 5 Check Digit
2Ch
Disable
9-44
Convert I 2 of 5 to EAN 13
52h
Disable
9-45
Discrete 2 of 5
05h
Disable
9-45
Set Length(s) for D 2 of 5
14h, 15h
12
9-46
Code 11
Interleaved 2 of 5 (ITF)
Discrete 2 of 5 (DTF)
1
User selection is required to configure this interface and this is the most common selection.
Page 233
Standard Default Parameters
Table A-1
A-7
Standard Default Parameters Table (Continued) Parameter
Parameter Number
Default
Page Number
Codabar (NW - 7) Codabar
07h
Disable
9-48
Set Lengths for Codabar
18h, 19h
5 to 55
9-48
CLSI Editing
36h
Disable
9-50
NOTIS Editing
37h
Disable
9-50
Codabar Upper or Lower Case Start/Stop Characters Detection
F2h 57h
Lower Case
9-51
MSI
0Bh
Disable
9-52
Set Length(s) for MSI
1Eh, 1Fh
4 to 55
9-52
MSI Check Digits
32h
One
9-54
Transmit MSI Check Digit
2Eh
Disable
9-54
MSI Check Digit Algorithm
33h
Mod 10/Mod 10
9-55
F0h 98h
Disable
9-55
Matrix 2 of 5
F1h 6Ah
Disable
9-56
Matrix 2 of 5 Lengths
F1h 6Bh F1h 6Ch
1 Length - 14
9-57
Matrix 2 of 5 Check Digit
F1h 6Eh
Disable
9-58
Transmit Matrix 2 of 5 Check Digit
F1h 6Fh
Disable
9-58
Korean 3 of 5
F1h 45h
Disable
9-59
Inverse 1D
F1h 4Ah
Regular
9-60
GS1 DataBar (GS1 DataBar Omnidirectional, GS1 DataBar Truncated, GS1 DataBar Stacked, GS1 DataBar Stacked Omnidirectional)
F0h 52h
Enable
9-61
GS1 DataBar Limited
F0h 53h
Disable
9-62
GS1 DataBar Limited Security Level
F1h D8h
3
9-63
MSI
Chinese 2 of 5 Chinese 2 of 5 Matrix 2 of 5
Korean 3 of 5
GS1 DataBar
1
User selection is required to configure this interface and this is the most common selection.
Page 234
A-8
DS9208-1D Product Reference Guide
Table A-1
Standard Default Parameters Table (Continued) Parameter
Parameter Number
Default
Page Number
GS1 DataBar Expanded (GS1 DataBar Expanded, GS1 DataBar Expanded Stacked)
F0h 54h
Enable
9-64
Convert GS1 DataBar to UPC/EAN
F0h 8Dh
Disable
9-64
Redundancy Level
4Eh
1
9-65
Security Level (UPC/EAN and Code 93)
4Dh
0
9-67
Intercharacter Gap Size
F0h 7Dh
Normal
9-68
Symbology-Specific Security Levels
1