Page 185

Symbologies 9 - 31

Set Lengths for Code 39 Parameter # L1 = 12h, L2 = 13h The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 39 to any length, one or two discrete lengths, or lengths within a specific range. If Code 39 Full ASCII is enabled, Length Within a Range or Any Length are the preferred options. NOTE

When setting lengths for different bar code types, enter a leading zero for single digit numbers.

• One Discrete Length - Select this option to decode only Code 39 symbols containing a selected length. Select the length using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only Code 39 symbols with 14 characters, scan Code 39 - One Discrete Length, then scan 1 followed by 4. To correct an error or change the selection, scan Cancel on page D-2.

• Two Discrete Lengths - Select this option to decode only Code 39 symbols containing either of two selected lengths. Select lengths using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only Code 39 symbols containing either 2 or 14 characters, select Code 39 - Two Discrete Lengths, then scan 0, 2, 1, and then 4. To correct an error or change the selection, scan Cancel on page D-2.

• Length Within Range - Select this option to decode a Code 39 symbol with a specific length range. Select lengths using numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode Code 39 symbols containing between 4 and 12 characters, first scan Code 39 - Length Within Range. Then scan 0, 4, 1, and 2 (enter a leading zero for single digit numbers). To correct an error or change the selection, scan Cancel on page D-2.

• Any Length - Select this option to decode Code 39 symbols containing any number of characters within the digital scanner’s capability.

Code 39 - One Discrete Length

Code 39 - Two Discrete Lengths

*Code 39 - Length Within Range

Code 39 - Any Length

Page 186

9 - 32 DS9208-1D Product Reference Guide

Code 39 Check Digit Verification Parameter # 30h Enable this feature to check the integrity of all Code 39 symbols to verify that the data complies with specified check digit algorithm. Only Code 39 symbols which include a modulo 43 check digit are decoded. Enable this feature if the Code 39 symbols contain a Modulo 43 check digit.

Enable Code 39 Check Digit (01h)

*Disable Code 39 Check Digit (00h)

Transmit Code 39 Check Digit Parameter # 2Bh Scan a bar code below to transmit Code 39 data with or without the check digit.

Transmit Code 39 Check Digit (Enable) (01h)

*Do Not Transmit Code 39 Check Digit (Disable) (00h) NOTE

Code 39 Check Digit Verification must be enabled for this parameter to function.

Page 187

Symbologies 9 - 33

Code 39 Full ASCII Conversion Parameter # 11h Code 39 Full ASCII is a variant of Code 39 which pairs characters to encode the full ASCII character set. To enable or disable Code 39 Full ASCII, scan the appropriate bar code below.

Enable Code 39 Full ASCII (01h)

*Disable Code 39 Full ASCII (00h) NOTE

You cannot enable Trioptic Code 39 and Code 39 Full ASCII simultaneously. Code 39 Full ASCII to Full ASCII Correlation is host-dependent, and is therefore described in the ASCII Character Set Table for the appropriate interface. See the ASCII Character Set for USB on page 5-19 or the ASCII Character Set for RS-232 on page 6-19.

Page 188

9 - 34 DS9208-1D Product Reference Guide

Code 39 Buffering Parameter # 71h This feature allows the digital scanner to accumulate data from multiple Code 39 symbols. Enabling Code 39 Buffering temporarily buffers all Code 39 symbols having a leading space as a first character for later transmission. The leading space is not buffered. Decoding a Code 39 symbol with no leading space transmits in sequence all buffered data in a first-in first-out format, plus the “triggering” symbol. See the following pages for further details. Select Disable Code 39 Buffering to transmit all decoded Code 39 symbols immediately without storing them in the buffer. This feature affects Code 39 only. If enabling Code 39 Buffering, we recommend configuring the digital scanner to decode the Code 39 symbology only.

Enable Code 39 Buffering (01h)

*Disable Code 39 Buffering (00h)

While there is data in the transmission buffer, you cannot select Disable Code 39 Buffering. The buffer holds 200 bytes of information. To disable Code 39 Buffering when there is data in the transmission buffer, first force the buffer transmission (see Transmit Buffer on page 9-35) or clear the buffer.

Buffer Data To buffer data, enable Code 39 Buffering and scan a Code 39 symbol with a space immediately following the start pattern.

• Unless the data overflows the transmission buffer, the digital scanner issues a low/high beep to indicate successful decode and buffering. For overflow conditions, see Overfilling Transmission Buffer on page 9-35.

• The digital scanner adds the decoded data excluding the leading space to the transmission buffer. • No transmission occurs.

Clear Transmission Buffer To clear the transmission buffer, scan the Clear Buffer bar code, which contains only a start character, a dash (minus), and a stop character.

• The digital scanner issues a short high/low/high beep. • The digital scanner erases the transmission buffer. • No transmission occurs.

Page 189

Symbologies 9 - 35

Clear Buffer NOTE

Because the Clear Buffer bar code contains only the dash (minus) character, use Set Lengths for Code 39 to include length 1 in order to scan this command.

Transmit Buffer There are two methods to transmit the Code 39 buffer. 1.

Scan the Transmit Buffer bar code, which includes only a start character, a plus (+), and a stop character.

2.

The digital scanner transmits and clears the buffer.

• The digital scanner issues a low/high beep.

Transmit Buffer 3.

Scan a Code 39 bar code with a leading character other than a space.

• The digital scanner appends new decode data to buffered data. • The digital scanner transmits and clears the buffer. • The digital scanner signals that it transmitted the buffer with a low/high beep. • The digital scanner transmits and clears the buffer. NOTE

Because the Transmit Buffer bar code contains only a plus (+) character, use Set Lengths for Code 39 to include length 1 in order to scan this command

Overfilling Transmission Buffer The Code 39 buffer holds 200 characters. If the symbol just read overflows the transmission buffer:

• The digital scanner indicates that it rejected the symbol by issuing three long, high beeps. • No transmission occurs. The data in the buffer is not affected.

Attempt to Transmit an Empty Buffer If you scan the Transmit Buffer symbol and the Code 39 buffer is empty:

• A short low/high/low beep signals that the buffer is empty. • No transmission occurs. • The buffer remains empty.

Page 190

9 - 36 DS9208-1D Product Reference Guide

Code 93 Enable/Disable Code 93 Parameter # 09h To enable or disable Code 93, scan the appropriate bar code below.

Enable Code 93 (01h)

*Disable Code 93 (00h)

Set Lengths for Code 93 Parameter # L1 = 1Ah, L2 = 1Bh The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 93 to any length, one or two discrete lengths, or lengths within a specific range.

• One Discrete Length - Select this option to decode only Code 93 symbols containing a selected length. Select the length using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only Code 93 symbols with 14 characters, scan Code 93 - One Discrete Length, then scan 1 followed by 4. To correct an error or to change the selection, scan Cancel on page D-2.

• Two Discrete Lengths - Select this option to decode only Code 93 symbols containing either of two selected lengths. Select lengths using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only Code 93 symbols containing either 2 or 14 characters, select Code 93 - Two Discrete Lengths, then scan 0, 2, 1, and then 4. To correct an error or to change the selection, scan Cancel on page D-2.

• Length Within Range - Select this option to decode a Code 93 symbol with a specific length range. Select lengths using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode Code 93 symbols containing between 4 and 12 characters, first scan Code 93 - Length Within Range. Then scan 0, 4, 1, and 2 (enter a leading zero for single digit numbers). To correct an error or change the selection, scan Cancel on page D-2.

• Any Length - Scan this option to decode Code 93 symbols containing any number of characters within the digital scanner’s capability.

Page 191

Symbologies 9 - 37

Set Lengths for Code 93 (continued)

Code 93 - One Discrete Length

Code 93 - Two Discrete Lengths

*Code 93 - Length Within Range

Code 93 - Any Length

Page 192

9 - 38 DS9208-1D Product Reference Guide

Code 11 Code 11 Parameter # 0Ah To enable or disable Code 11, scan the appropriate bar code below.

Enable Code 11 (01h)

*Disable Code 11 (00h)

Set Lengths for Code 11 Parameter # L1 = 1Ch, L2 = 1Dh The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 11 to any length, one or two discrete lengths, or lengths within a specific range.

• One Discrete Length - Select this option to decode only Code 11 symbols containing a selected length. Select the length using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only Code 11 symbols with 14 characters, scan Code 11 - One Discrete Length, then scan 1 followed by 4. To correct an error or to change the selection, scan Cancel on page D-2.

• Two Discrete Lengths - Select this option to decode only Code 11 symbols containing either of two selected lengths. Select lengths using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only Code 11 symbols containing either 2 or 14 characters, select Code 11 - Two Discrete Lengths, then scan 0, 2, 1, and then 4. To correct an error or to change the selection, scan Cancel on page D-2.

• Length Within Range - Select this option to decode a Code 11 symbol with a specific length range. Select lengths using numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode Code 11 symbols containing between 4 and 12 characters, first scan Code 11 - Length Within Range. Then scan 0, 4, 1, and 2 (enter a leading zero for single digit numbers). To correct an error or change the selection, scan Cancel on page D-2.

• Any Length - Scan this option to decode Code 11 symbols containing any number of characters within the digital scanner’s capability.

Page 193

Symbologies 9 - 39

Set Lengths for Code 11 (continued)

Code 11 - One Discrete Length

Code 11 - Two Discrete Lengths

*Code 11 - Length Within Range

Code 11 - Any Length

Page 194

9 - 40 DS9208-1D Product Reference Guide

Code 11 Check Digit Verification Parameter # 34h This feature allows the digital scanner to check the integrity of all Code 11 symbols to verify that the data complies with the specified check digit algorithm. This selects the check digit mechanism for the decoded Code 11 bar code. The options are to check for one check digit, check for two check digits, or disable the feature. To enable this feature, scan the bar code below corresponding to the number of check digits encoded in the Code 11 symbols.

*Disable (00h)

One Check Digit (01h)

Two Check Digits (02h)