Page 155

CHAPTER 9 SYMBOLOGIES Introduction This chapter describes symbology features and provides programming bar codes for selecting these features. Before programming, follow the instructions in Chapter 1, Getting Started. To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when the digital scanner powers down. NOTE

Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where you can see the bar code clearly, and bars and/or spaces do not merge.

Select a host type (see each host chapter for specific host information) after the power-up beeps sound. This is only necessary upon the first power-up when connected to a new host. To return all features to default values, scan the Set Default Parameter on page 4-4. Throughout the programming bar code menus, asterisks (*) indicate default values.

* Indicates Default

*Enable UPC-A (01h)

Feature/Option Option Hex Value

Scanning Sequence Examples In most cases, scanning one bar code sets the parameter value. For example, to transmit bar code data without the UPC-A check digit, simply scan the Do Not Transmit UPC-A Check Digit bar code under Transmit UPC-A Check Digit on page 9-16. The digital scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry. Other parameters, such as Set Length(s) for D 2 of 5 require scanning several bar codes. See the individual parameter, such as Set Length(s) for D 2 of 5, for this procedure.

Page 156

9-2

DS9208-1D Product Reference Guide

Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.

Symbology Parameter Defaults Table 9-1 lists the defaults for all symbologies parameters. To change the default values, scan the appropriate bar codes in this guide. These new values replace the standard default values in memory. To recall the default parameter values, scan the Set Default Parameter on page 4-4. NOTE

See Appendix A, Standard Default Parameters for all user preferences, hosts, and miscellaneous default parameters.

Table 9-1 Parameter Defaults

Parameter

Parameter Number

Default

Disable All Code Types

Page Number 9-6

UPC/EAN UPC-A

01h

Enable

9-7

UPC-E

02h

Enable

9-7

UPC-E1

0Ch

Disable

9-8

EAN-8/JAN 8

04h

Enable

9-8

EAN-13/JAN 13

03h

Enable

9-9

Bookland EAN

53h

Disable

9-9

Bookland ISBN Format

F1h 40h

ISBN-10

9-10

Decode UPC/EAN/JAN Supplementals (2 and 5 digits)

10h

Ignore

9-12

User-Programmable Supplementals Supplemental 1: Supplemental 2:

N/A

9-14

F1h 43h F1h 44h

UPC/EAN/JAN Supplemental Redundancy

50h

10

9-14

Decode UPC/EAN/JAN Supplemental AIM ID

F1h A0h

Combined

9-15

Transmit UPC-A Check Digit

28h

Enable

9-16

Transmit UPC-E Check Digit

29h

Enable

9-16

Transmit UPC-E1 Check Digit

2Ah

Enable

9-17

UPC-A Preamble

22h

System Character

9-17

UPC-E Preamble

23h

System Character

9-18

UPC-E1 Preamble

24h

System Character

9-19

Page 157

Symbologies

9-3

Table 9-1 Parameter Defaults (Continued)

Parameter

Parameter Number

Default

Page Number

Convert UPC-E to A

25h

Disable

9-20

Convert UPC-E1 to A

26h

Disable

9-20

EAN-8/JAN-8 Extend

27h

Disable

9-21

UCC Coupon Extended Code

55h

Disable

9-21

Coupon Report

F1h DAh

New Coupon Symbols

9-22

ISSN EAN

F1h 69h

Enable

9-23

Code 128

08h

Enable

9-24

Set Length(s) for Code 128

D1h, D2h

Any Length

9-24

GS1-128 (formerly UCC/EAN-128)

0Eh

Enable

9-25

ISBT 128

54h

Enable

9-26

ISBT Concatenation

F1h 41h

Disable

9-27

Check ISBT Table

F1h 42h

Enable

9-28

ISBT Concatenation Redundancy

DFh

10

9-28

Code 39

00h

Enable

9-29

Trioptic Code 39

0Dh

Disable

9-29

Convert Code 39 to Code 32 (Italian Pharmacy Code)

56h

Disable

9-30

Code 32 Prefix

E7h

Disable

9-30

Set Length(s) for Code 39

12h, 13h

Length Within Range: 2 to 55

9-31

Code 39 Check Digit Verification

30h

Disable

9-32

Transmit Code 39 Check Digit

2Bh

Disable

9-32

Code 39 Full ASCII Conversion

11h

Disable

9-33

Code 39 Buffering

71h

Disable

9-34

Code 128

Code 39

Clear Buffer

9-35

Transmit Buffer

9-35

Code 93 Code 93

09h

Disable

9-36

Set Length(s) for Code 93

1Ah, 1Bh

Length Within Range: 4 to 55

9-36

Page 158

9-4

DS9208-1D Product Reference Guide

Table 9-1 Parameter Defaults (Continued)

Parameter

Parameter Number

Default

Page Number

Code 11 Code 11

0Ah

Disable

9-38

Set Lengths for Code 11

1Ch, 1Dh

Length Within Range: 4 to 55

9-38

Code 11 Check Digit Verification

34h

Disable

9-40

Transmit Code 11 Check Digit(s)

2Fh

Disable

9-41

Interleaved 2 of 5 (ITF)

06h

Disable

9-41

Set Lengths for I 2 of 5

16h, 17h

1 Length; Length = 14

9-41

I 2 of 5 Check Digit Verification

31h

Disable

9-44

Transmit I 2 of 5 Check Digit

2Ch

Disable

9-44

Convert I 2 of 5 to EAN 13

52h

Disable

9-45

Discrete 2 of 5

05h

Disable

9-45

Set Length(s) for D 2 of 5

14h, 15h

1 Length; Length = 12

9-46

Codabar

07h

Disable

9-48

Set Lengths for Codabar

18h, 19h

Length Within Range: 5 to 55

9-48

CLSI Editing

36h

Disable

9-50

NOTIS Editing

37h

Disable

9-50

Codabar Upper or Lower Case Start/Stop Characters Detection

F2h 57h

Lower Case

9-51

MSI

0Bh

Disable

9-52

Set Length(s) for MSI

1Eh, 1Fh

Length Within Range: 4 to 55

9-52

MSI Check Digits

32h

One

9-54

Transmit MSI Check Digit

2Eh

Disable

9-54

MSI Check Digit Algorithm

33h

Mod 10/Mod 10

9-55

Interleaved 2 of 5 (ITF)

Discrete 2 of 5 (DTF)

Codabar (NW - 7)

MSI

Page 159

Symbologies

9-5

Table 9-1 Parameter Defaults (Continued)

Parameter

Parameter Number

Default

Page Number

Chinese 2 of 5 Chinese 2 of 5

F0h 98h

Disable

9-55

Matrix 2 of 5

F1h 6Ah

Disable

9-56

Matrix 2 of 5 Lengths

F1h 6Bh F1h 6Ch

Length; Length = 14

9-57

Matrix 2 of 5 Check Digit

F1h 6Eh

Disable

9-58

Transmit Matrix 2 of 5 Check Digit

F1h 6Fh

Disable

9-58

Korean 3 of 5

F1h 45h

Disable

9-59

Inverse 1D

F1h 4Ah

Regular

9-60

GS1 DataBar (GS1 DataBar Omnidirectional, GS1 DataBar Truncated, GS1 DataBar Stacked, GS1 DataBar Stacked Omnidirectional)

F0h 52h

Enable

9-61

GS1 DataBar Limited

F0h 53h

Disable

9-62

GS1 DataBar Limited Security Level

F1h D8h

3

9-63

GS1 DataBar Expanded (GS1 DataBar Expanded, GS1 DataBar Expanded Stacked)

F0h 54h

Enable

9-64

Convert GS1 DataBar to UPC/EAN

F0h 8Dh

Disable

9-64

Redundancy Level

4Eh

1

9-65

Security Level (UPC/EAN and Code 93)

4Dh

0

9-67

Intercharacter Gap Size

F0h 7Dh

Normal

9-68

Matrix 2 of 5

Korean 3 of 5

GS1 DataBar

Symbology-Specific Security Levels

Page 160

9-6

DS9208-1D Product Reference Guide

Disable All Code Types To disable all symbologies, scan the bar code below. This is useful when enabling only a few code types.

Disable All Code Types

Page 161

Symbologies

UPC/EAN Enable/Disable UPC-A Parameter # 01h To enable or disable UPC-A, scan the appropriate bar code below.

*Enable UPC-A (01h)

Disable UPC-A (00h)

Enable/Disable UPC-E Parameter # 02h To enable or disable UPC-E, scan the appropriate bar code below.

*Enable UPC-E (01h)

Disable UPC-E (00h)

9-7

Page 162

9-8

DS9208-1D Product Reference Guide

Enable/Disable UPC-E1 Parameter # 0Ch UPC-E1 is disabled by default. To enable or disable UPC-E1, scan the appropriate bar code below. UPC-E1 is not a UCC (Uniform Code Council) approved symbology.

NOTE

Enable UPC-E1 (01h)

*Disable UPC-E1 (00h)

Enable/Disable EAN-8/JAN-8 Parameter # 04h To enable or disable EAN-8/JAN-8, scan the appropriate bar code below.

*Enable EAN-8/JAN-8 (01h)

Disable EAN-8/JAN-8 (00h)

Page 163

Symbologies

9-9

Enable/Disable EAN-13/JAN-13 Parameter # 03h To enable or disable EAN-13/JAN-13, scan the appropriate bar code below.

*Enable EAN-13/JAN-13 (01h)

Disable EAN-13/JAN-13 (00h)

Enable/Disable Bookland EAN Parameter # 53h To enable or disable Bookland EAN, scan the appropriate bar code below.

Enable Bookland EAN (01h)

*Disable Bookland EAN (00h)

NOTE

If Bookland EAN is enabled, select a Bookland ISBN Format on page 9-10. Also select either Decode UPC/EAN Supplementals, Autodiscriminate UPC/EAN Supplementals, or Enable 978/979 Supplemental Mode in Decode UPC/EAN/JAN Supplementals on page 9-11.

Page 164

9 - 10 DS9208-1D Product Reference Guide

Bookland ISBN Format Parameter # F1h 40h If Bookland EAN is enabled, select one of the following formats for Bookland data:

• Bookland ISBN-10 - The digital scanner reports Bookland data starting with 978 in traditional 10-digit format with the special Bookland check digit for backward-compatibility. Data starting with 979 is not considered Bookland in this mode.

• Bookland ISBN-13 - The digital scanner reports Bookland data (starting with either 978 or 979) as EAN-13 in 13-digit format to meet the 2007 ISBN-13 protocol.

*Bookland ISBN-10 (00h)

Bookland ISBN-13 (01h)

NOTE

For Bookland EAN to function properly, ensure Bookland EAN is enabled (see Enable/Disable Bookland EAN on page 9-9), then select either Decode UPC/EAN Supplementals, Autodiscriminate UPC/EAN Supplementals, or Enable 978/979 Supplemental Mode in Decode UPC/EAN/JAN Supplementals on page 9-11.