Page 127
CHAPTER 7 IBM 468X / 469X INTERFACE Introduction This chapter describes how to set up the digital scanner with an IBM 468X/469X host. Throughout the programming bar code menus, asterisks (*) indicate default values.
* Indicates Default
NOTE
*Disable Convert to Code 39
Feature/Option
Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where you can see the bar code clearly, and bars and/or spaces are not merging.
Page 128
7-2
DS9208-1D Product Reference Guide
Connecting to an IBM 468X/469X Host Connect the digital scanner directly to the host interface.
Interface Cable
Host Port Connector
Figure 7-1 IBM Direct Connection NOTE
Interface cables vary depending on configuration. The connectors illustrated in Figure 7-1 are examples only. The connectors may be different than those illustrated, but the steps to connect the digital scanner are the same.
1.
Attach the modular connector of the IBM 46XX interface cable to the cable interface port on the digital scanner. See Installing the Interface Cable on page 1-3.
2.
Connect the other end of the IBM 46XX interface cable to the appropriate port on the host (typically Port 9).
3.
Select the port address by scanning the appropriate bar code from Port Address on page 7-4.
4.
To modify any other parameter options, scan the appropriate bar codes in this chapter. NOTE
The only required configuration is the port address. The IBM system typically controls other digital scanner parameters.
Page 129
IBM 468X / 469X Interface
7-3
IBM Parameter Defaults Table 7-1 lists the defaults for IBM host parameters. To change any option, scan the appropriate bar code(s) provided in the Parameter Descriptions section beginning on page 7-4. NOTE
See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
Table 7-1 IBM Host Default Table
Parameter
Default
Page Number
IBM 468X/469X Host Parameters Port Address
None Selected
7-4
Convert Unknown to Code 39
Disable
7-5
Ignore Beep Directive
Honor
7-5
Ignore Configuration Directive
Honor
7-6
Page 130
7-4
DS9208-1D Product Reference Guide
IBM 468X/469X Host Parameters Port Address This parameter sets the IBM 468X/469X port used. NOTE
Scanning one of these bar codes enables the RS-485 interface on the digital scanner.
*None Selected
Hand-Held Scanner Emulation (Port 9B)
Non-IBM Scanner Emulation (Port 5B)
Table Top Scanner Emulation (Port 17)
Page 131
IBM 468X / 469X Interface
7-5
Convert Unknown to Code 39 Scan a bar code below to enable or disable the conversion of unknown bar code type data to Code 39.
Enable Convert Unknown to Code 39
*Disable Convert Unknown to Code 39 Ignore Beep Directive Scan one of the following bar codes to honor or ignore a beep directive made over the IBM RS-485 bus. All directives are still acknowledged to the IBM RS-485 host as if they were processed.
*Honor Beep Directive
Ignore Beep Directive
Page 132
7-6
DS9208-1D Product Reference Guide
Ignore Configuration Directive Scan one of the following bar codes to honor or ignore a code type enable/disable directive made over the IBM RS-485 bus. All directives are still acknowledged to the IBM RS-485 host as if they were processed.
*Honor Configuration Directive
Ignore Configuration Directive