The text of a manual · part 9 of 21
Monarch DOS-based PATHFINDER Ultra System, pages 81 to 90
Pages 81 to 90 of 210
The original document is the PDF (4.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Monarch Ultra 6035
Page 81
This sample prints the following label.
Defining Bar Code Fields 6-23
Page 82
Bar Code Specifications This section contains information specific to the various bar codes you can select. This information helps you correctly enter the information to create a bar code field for your format.
UPC Bar Codes ♦
Retailers use UPC (Universal Product Code) bar codes to identify merchandise. ♦ Maximum and minimum lengths for +2 and +5 bar codes must be equal.
Bar Code
Length (in characters)
UPC-A
12
UPC-A +2
14
UPC-A +5
17
UPC-A & Price CD
12
UPC-E
7
UPC-E +2
9
UPC-E +5
12
UPCA
6-24 Defining Bar Code Fields
UPCE
Page 83
EAN Bar Codes ♦
Some retailers use EAN (European Article Number) bar codes to identify merchandise. ♦ Maximum and minimum lengths for +2 and +5 bar codes must be equal. Bar Code
Length (in characters)
EAN-8
8
EAN-8 +2
10
EAN-8 +5
13
EAN-13
13
EAN-13 +2
15
EAN-13 +5
18
EAN-13 & Price CD
13
EAN-8
EAN-13
Code 128 Bar Codes ♦
Length:0 – 2710 characters ♦ Characters are alphanumeric, including any ASCII characters.
Defining Bar Code Fields 6-25
Page 84
MSI MSI is a Modified Plessey bar code. ♦ Length: 0 – 14 characters ♦ Uses only numeric data. ♦ Can use a second optional check digit.
Interleaved 2 of 5 Bar Codes Interleaved 2 of 5 is an industrial bar code. You can use it with or without a barrier bar. ♦ Length: 0 – 2710 characters (must be numeric) ♦ The length must be even. If not, the software adds a zero at the end.
Interleaved 2 of 5
Interleaved 2 of 5 with the Barrier Bar
Code 39 Bar Codes Code 39 is an industrial bar code. You can use Code 39 with no check digit and Code 39 – Mod 43. ♦ Uses alphanumeric data, certain symbols, and start/stop characters. ♦ Length: 0 – 2710 characters
6-26 Defining Bar Code Fields
Page 85
Codabar Bar Codes Codabar is an industrial bar code with numeric printing and special start/stop characters. You can use the start/stop characters to join multiple bar codes when scanning. ♦ To join two bar codes, the last character of one bar code and the first character of the other bar code must be d. ♦ Other start and stop characters can be a, b, and c. ♦ Length: 0 – 26 characters
Code 93 ♦
Uses data from the 128 character ASCII set. ♦ Uses two check digits. ♦ Length: 0 - 2710 characters
Defining Bar Code Fields 6-27
Page 86
6-28 Defining Bar Code Fields
Page 87
DEFINING CONSTANT TEXT FIELDS
7
A constant text field is a set of fixed characters that prints on all labels. Define each constant text field separately. Use constant text fields for data that is the same, so the operator does not have to enter the repetitive data for each label. For example, a store number should be in a constant text field, whereas the department number should be in a text field. The store number is the same for each label. The department number varies per label. NOTE: The constant text field is not assigned a field number, but is counted as a field (keep this in mind, as the printer allows a maximum of 50 fields per format). Data edits do not apply to constant text fields. Constant text fields are very similar to text fields. NOTE: All samples shown in this chapter are created using 2.0-inch long by 2.0-inch wide supplies.
About Constant Text Fields Read the following information to become familiar with the prompts for constant text fields. Valid ranges for the prompts are listed as well as information about using constant text fields. Format Name
Depending on your printer’s configuration, enter a name for the format. For more information about your printer’s configuration, see Chapter 3, “Configuring the Printer.” The maximum number of characters for the format name is 16.
Format Number
Reserved for future use. (Depending on your printer’s configuration, enter a number for the format. The format number range is 1 – 99.)
Format Description
Reserved for future use. (Depending on your printer’s configuration, enter a description for the format.)
Supply Length
The length of your loaded supply. Measure from the top of one black mark to the top of the next black mark. The standard supply lengths are: 55, 78, 110, 150, 200, 300, or 400 inches.
Defining Constant Text Fields 7-1
Page 88
Supply Width
The width of your loaded supply. Choices include 1.20, 1.50, or 2.00 inches.
Field Type
Choices include text, bar code, constant text, and line.
Fixed Data
In situations where the same data appears on all labels, you can enter the repetitive data as fixed data. The operator does not enter the data. The maximum number of characters is 40; however, each field has a maximum length defined, so the fixed data must be below that maximum. Fixed data is stored with the format and automatically displayed with the prompt during data entry.
Row
The horizontal line where printing begins. For monospaced fonts, distance from the bottom of print area to the pivot point. The pivot point varies depending on how text is justified.
For proportionally spaced fonts, distance from the bottom of print area to baseline of characters in field. The range is 0 – 365. Baseline
Column
The vertical line where printing begins. Type the column position for the field. The distance from the left edge of the print area to the pivot point is the column location. The range is 0 – 183. Baseline
7-2 Defining Constant Text Fields
Page 89
Gap
Depending on your printer’s configuration, enter the number of dots between characters. For more information about your printer’s configuration, see Chapter 3, “Configuring the Printer.” The gap range is 0 – 9. For mono-spaced fonts, the additional spacing is added to the existing inter-character gap. This is also true for proportionally spaced fonts, but the inter-character gap varies with character combinations. Any number other than 0 affects your field width. Default spacing: Letter Gothic Bold 6pt 1 dot Letter Gothic Bold 9pt 2 dots All other fonts vary with each letter Use the default unless you want to create a special effect, such as P R I C E (additional character spacing) in a field.
Font
The style of font for your format. Choices include CG Triumvirate Bold 6.5, 8, 10, 12, 18, or 22 point; CG Triumvirate Bold Condensed 6.5, 8, 10, 12, 18, and 22 point; and Letter Gothic 6.5 and 9 point.
Height Magnification
Height magnifier for the selected font. Use a magnifier of 1 with proportionally spaced fonts, because characters lose smoothness at higher magnifications. The range is 1 – 7.
Width Magnification
Width magnifier for the selected font. Proportionally spaced fonts do not have a set width. The range is 1 – 7.
Defining Constant Text Fields 7-3
Page 90
Font Color Line field not blocked out by transparent field using attribute O Line field blocked out by opaque field using attribute B
Depending on your printer’s configuration, enter the color of the selected font. For more information about your printer’s configuration, see Chapter 3, “Configuring the Printer.” Solid black print should not exceed 30% on a given square inch of the label, or printhead life may be decreased. There are two types of field color overlay attributes: Transparent The overlay field (text or constant text) does not block out or “erase” existing fields. Opaque
The overlay field blocks out or “erases” existing fields. Field placement is an important consideration when using field color attributes. If a line field is defined before the overlay (text or constant text) field, the line field is blocked out by the overlay field, depending on the overlay field's color attribute. If a line field is defined after the overlay field, the line field is not blocked out by the overlay field, regardless of the overlay field's color attribute. Choices include Black Opaque, White Opaque, Black Transparent and White Transparent.
Justification
Alignment of the text within the field. Choices include Left (L), Right (E), and Center (B). Fonts 1012 and 1013 (Letter Gothic 6.5 and 9 pt) default to L (left).
Character Rotation
Depending on your printer’s configuration, enter the character rotation of the selected field. For more information about your printer’s configuration, see Chapter 3, “Configuring the Printer.” Choices include Top of Field, Left of Field, Bottom of Field, and Right of Field. The field or supply does not rotate, only the characters do. See “ABCD” in the example below.
7-4 Defining Constant Text Fields