Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 6 of 9

DOS-based PATHFINDER Ultra System, pages 51 to 60

Pages 51 to 60 of 87

The original document is the PDF (1.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Monarch Ultra 6035

Page 51

To clean the platen roller: 1. Turn the printer off and open the supply cover. 2. Remove your supply. See "Removing Supplies" in Chapter 3. 3. Open the label deflector by gently pressing down with two fingers. 4. Clean the platen roller and remove any adhesive buildup.

Platen Roller

5. Turn the platen roller with your finger, and then continue cleaning. 6. Reload your supply and close the label deflector and supply cover.

6-6 Care and Maintenance

TC6035EZEM Rev. C 10/98

Page 52

Cleaning the Sensors To clean the on-demand sensor: 1. Turn the printer off and open the supply cover. 2. Open the label deflector by gently pressing down with two fingers. 3. Clean the on-demand sensor with a soft cloth moistened with water.

On-Demand Sensor

TC6035EZEM Rev. C 10/98

Care and Maintenance 6-7

Page 53

To clean the black mark sensor: 1. Turn the printer off, open the supply cover and remove the supplies. 2. Clean the black mark sensor with a soft cloth moistened with water.

Black Mark Sensor

6-8 Care and Maintenance

TC6035EZEM Rev. C 10/98

Page 54

Storing the Printer Store the printer with a handle attached. Do Not store the printer in or near u magnetic fields u wet or damp areas u dirty or dusty areas u areas of intense vibration or shock. CAUTION Storage in or near these areas can damage the printer and void your warranty.

TC6035EZEM Rev. C 10/98

Care and Maintenance 6-9

Page 55

6-10 Care and Maintenance

TC6035EZEM Rev. C 10/98

Page 56

USING DIAGNOSTICS

7

Only Service or a System Administrator should use diagnostics. You can use diagnostics to u check display characteristics u check keyboard connections u test the serial port u test the scanner u check the speaker u check the printer u check the versions of various parts of the printer. The screens shown in this chapter will differ (more information will appear) if you are using an 8-line/48 Key Printer.

TC6035EZEM Rev. C 10/98

Using Diagnostics 7-1

Page 57

To access these options, you need to use the Diagnostic program. To start the Diagnostic program: 1. 4-line/33 Key Printer Only. From the DOS prompt, press s(if not already in Shift mode). 2. Type DIAG and press e. You will see: DOS Ultra Diagnostic Display Keyboard Serial Port

D

The currently selected diagnostic function is displayed in inverse mode. An arrow to the right of the display means that there are more functions. 3. 4-line/33 Key Printer Only. Press s to return to normal mode. 4. Scroll with the arrow keys until you highlight the diagnostic function you want to use. Press e. Use the right or down arrow keys to scroll down the list of functions. Use the left or up arrow keys to scroll up the list. To exit any diagnostic function, press b or scroll to Exit in the menu and press e.

7-2 Using Diagnostics

TC6035EZEM Rev. C 10/98

Page 58

Checking Display Characteristics The Display diagnostic menu provides the following selections: Backlight

Turns the backlight on and off to ensure it is functioning properly. If the backlight does not turn on and then off, please make a note and call Service.

Pixel

Tests all the individual pixels on the display. One pixel line toward the bottom of the printer will not have its pixels set. If any other positions are skipped, please make a note and call Service.

Character Set

Displays all available characters. If any character does not display properly, please make a note and call Service.

Character

Fills the third line of the display with a single character selected from the keyboard. If any problem is detected, please make a note and call Service.

To check display characteristics: 1. At the Main menu, scroll with the arrow keys until you highlight Display. Press e. You will see: Select LCD test Backlight Pixel Character Set

D

2. Scroll with the arrow keys to select the LCD test you want. Press e. Each diagnostic function displays directions for starting that test. Press b to exit.

TC6035EZEM Rev. C 10/98

Using Diagnostics 7-3

Page 59

Checking Keyboard Connections The Keyboard diagnostic function displays a keypad replica to test keyboard connections. To check keyboard connections: 1. At the Main menu, scroll with the arrow keys until you highlight Keyboard. Press e. You will see a replica of the printer keypad. 2. Press a key to verify the name of the key and its location on the replica. Press b twice to exit.

Te s t i n g t h e S e r i a l P o r t This test is typically performed by Service or your MIS department. To check the serial port, you perform a loopback test, which checks the port for receiving and sending data from a host. The loopback plug referred to in the procedure below is part number 116850, available as an accessory. To test the serial port: 1. At the Main menu, scroll with the arrow keys until you highlight Serial Port. Press e. You will see: Insert loopback plug into serial port connector. Press key to cont

7-4 Using Diagnostics

TC6035EZEM Rev. C 10/98

Page 60

2. Insert the loopback plug and press any key (except b) to start the test. Press b to exit. 3. When the test finishes, you will see Press Esc to cont. Testing speed: XX Testing parity: XX Testing ctrls: XX where XX is OK or err. Press b to exit. If the printer fails to send or receive data, please make a note and call Service.

Te s t i n g t h e S c a n n e r The Scanner diagnostic function provides the following selections: Trigger Scanner

Displays scanned bar code values for successful scans or no data for scan failures.

Configuration

Allows the user to enable or disable scanner features for specific bar code types, low power mode, and time-out mode.

To test the scanner: 1. At the Main menu, scroll with the arrow keys until you highlight Scanner. Press e. You will see: Select scanner test Trigger scanner Configuration About

D

2. Scroll with the arrow keys until you highlight the scanner test you want. Press e. Press b to exit.

TC6035EZEM Rev. C 10/98

Using Diagnostics 7-5