Page 71

Chapter 10. Using Diagnostics

After running any of the above tests, depending on the selection, press e or b to return to the menu.

n

Hardware tests are typically performed by an authorized Service representative. However, if you need to run any of these tests make sure you read the following sections. Each section provides the acceptable results of the test and when it is necessary to call Service. When calling Service, be sure to provide the exact results. To access the Hardware Tests: 1. From the DIAGNOSTIC MENU, press > until you see: Machine Totals Hardware Tests 2. Press e. You will see: HDW TEST MENU Printing 3. Continue with the steps for each test.

Printing Tests The PRINTING TESTS menu provides the following selections: F

Test Pattern

F

Print Speed

F

Gray Scale

F

Contrast Adjustment

Before you run these tests, be sure to load your supply in Non-Peel mode. See Chapter 3, "Loading Supplies." Test Pattern prints a label to verify that the printhead strobes are working.

10-5

Page 72

6030 Operator’s Handbook

The Print Speed test allows you to verify that the supply is moving through the printer at the correct speed for printing scannable bar codes. The Gray Scale test checks the uniformity of the printing. To run the Test Pattern: 1. Press e to select Printing from the HDW TEST MENU. You will see: PRINTING TESTS Test Pattern 2. Press e. You will see READY. 3. Press the trigger to print the test sample shown below.

If your printed test sample has fewer lines or no lines, keep the test sample and call Service.

n 10-6

This test must be performed in Non-Peel mode.

Page 73

Chapter 10. Using Diagnostics

To run the Print Speed test: 1. Press e to select Printing from the HDW TEST MENU. 2. From the PRINTING MENU, press > until you see: Test Pattern Print Speed 3. Press e. You will see READY. 4. Press the trigger to print the test sample. Use the metric scale below or a metric ruler to measure your test sample. If your test sample measures more than 101 mm or less than 99 mm, save your test sample and call Service.

n

This test must be performed in Non-peel mode.

To run the Gray Scale: 1. Press e to select Printing from the HDW TEST MENU. 2. From the PRINTING MENU, press > until you see: Print Speed Gray Scale 3. Press e. You will see READY.

10-7

Page 74

6030 Operator’s Handbook

4. Press the trigger to print the test sample. The test sample should be uniformly gray across the supply. If you see voids, especially on the edges, save your test sample and call Service.

Label with voids n 10-8

This test must be performed in Non-peel mode.

Page 75

Chapter 10. Using Diagnostics

To adjust the contrast: 1. Press eto select Printing from the HDW TEST MENU. 2. From the PRINTING MENU, press >until you see Contrast. 3. Press e. 4. At Supply Type?, use the arrow keys to select the supply type you need and press e. 5. At Bar code Type?, use the arrow keys to select the bar code type you need to adjust. Then press e. 1= Serial bar code printing 2= Parallel bar code printing 3= Both - Serial/Parallel bar code printing 4= MaxiCode bar code printing or b= Exit n

If you are not sure what Bar code Type you have, see "Sample of Bar Code Types." 6. At Contrast #1, 2 (or last value entered), press <or >to adjust the contrast in increments of +/- 1. The higher the number, the darker the print; the lower the number, the lighter the print. 7. Press e. The test sample shown prints automatically. The display returns to Contrast #. 8. Press b until the cursor is at the MAIN MENU.

10-9

Page 76

6030 Operator’s Handbook

Checking the Serial Port This test is typically performed by Service or your MIS department. To check the serial port, you perform a "loop-back" test, which checks the port for receiving and sending data from a host.

n

Contact your Service representative for the loop-back plug and procedures. To run the Serial Port test: 1. Connect the loop-back plug to the printer. 2. From the HDW TEST MENU, press > until you see: Printing Serial Port 3. Press e. You will see SENDING, and then F if the test is successful, you will automatically return to the HDW TEST MENU.

F if the test is unsuccessful, you will see: No Data Received PRESS A KEY

4. Press b. If the printer fails to send or receive data, please make a note and call Service.

10-10

Page 77

Chapter 10. Using Diagnostics

Checking the Sensors The SENSOR TESTS menu provides the following selections: F

On-Demand for testing the On-Demand sensor.

F

Black Mark for testing the Black Mark sensor.

To run the On-Demand test: 1. From the HDW TEST MENU, press > until you see: Serial Port Sensors 2. Press e. You will see: SENSORS TEST On-Demand 3. Press e. 4. Open the label deflector.

10-11

Page 78

6030 Operator’s Handbook

5. Hold a white label against the sensor as shown. a. When you cover the sensor with a label, you will see: DEMAND = ### BLOCKED Valid values are 480-999. b. When you remove the label from the sensor, you will see: DEMAND = ## CLEAR Valid values are 0-288. 6. Close the label deflector, and then press b. To run the Black Mark test: 1. From the HDW TEST MENU, press > until you see: Serial Port Sensors 2. Press e. You will see: SENSORS TEST On-Demand 3. Press > until you see: SENSORS TEST Black Mark 4. Press e. 5. Open the supply cover.

10-12

Page 79

Chapter 10. Using Diagnostics

6. Hold a black mark against the sensor as shown.

a. When you cover the sensor with white part of the label you will see: BLACK MARK = ### WHITE Valid values are 488-1023. b. When you place the black mark on the sensor, you will see: BLACK MARK = ### BLACK Valid values are 80-150. 7. Close the supply cover and press e. If the value is not within ranges, make a note and call Service.

10-13

Page 80

6030 Operator’s Handbook

Checking the Printhead The Printhead test checks for F dot resistance

F temperature.

The dot resistance test checks each dot on the printhead and takes approximately four minutes. The temperature test checks the working temperature range of the printhead. The temperature of the printer depends upon the number of labels printed and the operating environment. Temperature

Printhead Temperature

32° 70° 100°

1019 533 296

To run the Dot Resistance test: 1. From the HDW TEST MENU, press > until you see: Sensors Printhead 2. Press e. You will see: PRINTHEAD TESTS Dot Resistance 3. Press e. You will see the message AVG DOT = ###. Valid values are 270-313.

10-14