Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 10

Monarch 6030 PATHFINDER Ultra Printer Operator's Handbook, pages 31 to 40

Pages 31 to 40 of 92

The original document is the PDF (948 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Monarch Ultra 6030

Page 31

Chapter 4. Entering and Printing Data

Using Lowercase Alpha Mode This mode allows you to enter lowercase letters and use the up and down arrows. In Lowercase Alpha mode, the cursor is a blinking rectangle.

n

Lowercase Alpha mode allows you to enter and exit the European character set. To use Lowercase Alpha mode: 1. Press a to enter Lowercase Alpha mode. 2. Enter your data. 3. Press a to return to Numeric mode.

Using Special Character Mode Special Character mode allows you to enter up to three digits for ANSI characters. See Appendix A, "Reference Information," for the ANSI Character Table. In this mode, the cursor appears as an underscore. To use Special Character mode: 1. Press the appropriate key(s) to enter this mode: F s + a from Numeric mode.

F s from Uppercase Alpha mode.

F a from Lowercase Alpha mode.

2. Enter up to three digits for the ANSI character you want to use. If you enter fewer than three digits, you must press e. 3. Repeat these steps for each character you need.

4-5

Page 32

6030 Operator’s Handbook

Function Keys –––––––––––––––––––––––––––––––––––––––––––––– There are six function keys (A-f) on your printer keypad. These keys may be programmed to perform special functions. Ask your System Administrator if you need to use these keys. You must be in Numeric mode to use these function keys.

Using Applications ––––––––––––––––––––––––––––––––––––––––– Before using this printer, an application must be downloaded and active. You can use the Command mode to start and resume applications.

Starting an Application (Start App.) Your application may automatically start. Use Start App. to begin or execute your application. To start an application: 1. From the MAIN MENU, press > until you see: Resume App. Start App. 2. Press e.

n

If you see the message INVALID START, an application has not been downloaded to your printer. Ask your System Administrator for assistance. 3. See your System Administrator for details about your application.

4-6

Page 33

Chapter 4. Entering and Printing Data

Resuming an Application (Resume App.) Use Resume App. to return to where you exited your application. To resume an application: From the MAIN MENU, press e to select Resume App.

n

See your System Administrator for details about your application. If you see the message INVALID START, an application has not been downloaded to your printer. Ask your System Administrator for assistance.

Printing–––––––––––––––––––––––––––––––––––––––––––––––––––– Before you begin printing F start with a fully charged handle.

F load your supplies.

F make sure an application has been downloaded.

F attach the safety strap of the printer to your wrist.

There are two print modes: F

On-Demand mode

F

Continuous mode

Printing in On-Demand Mode In On-Demand mode, the printer prints a label each time you remove the previously printed label. On-Demand must be enabled before printing in this mode. It can be enabled in the application or in Command mode. See your System Administrator for information.

n

For On-Demand mode, you must load your labels for Peel mode.

4-7

Page 34

6030 Operator’s Handbook

To print labels in On-Demand mode: 1. Press the trigger. 2. Apply the label. The next label prints automatically. Repeat these steps to continue to print and apply more labels.

n

To remove excess backing paper, gently tear it against the exit chute.

Printing in Continuous Mode In Continuous mode, the printer prints one supply or a strip of supply with one press of the trigger. Supplies may be thermal labels, tags or specialty paper.

n

For Continuous mode, you must load supplies for Non-Peel mode. To print in Continuous mode: 1. Press the trigger. 2. When printing stops, cut the supply and remove the strip.

4-8

Page 35

Chapter 5.

Transferring Data

This chapter includes information about: Connecting the Communications Cable

To establish communications, you need to connect a cable interface. See "Connecting the Communications Cable" later in this chapter.

Receiving Data

You may want to download lookup tables, data collect records, format files or an application to the printer. See "Receiving Data" later in this chapter.

Sending Data

You may want to upload data collection records to the host. See "Sending Data" later in this chapter.

Setting the Communication Parameters

To send or receive data, the communications parameters at the printer must match the host. See "Setting Communications Parameters" later in this chapter.

Connecting the Communications Cable –––––––––––––––––––––––– Before you can send or receive data from the host, you must attach a fully charged handle and connect the communications cable.

n

Ask your System Administrator if you need to set the communications parameters in the printer. To connect the communications cable: 1. Turn the printer off.

5-1

Page 36

6030 Operator’s Handbook

2. Plug the mini-DIN connector of the cable into the printer.

n

Make sure the flat side of the connector faces the front of the printer.

Communications Port

Mini-DIN Connector

3. Plug the other end of the cable into the RS-232 serial port on the host. 4. Turn the printer on. 5. Select Send or Receive from the DATA TRANSFER menu. See "Receiving Data" or "Sending Data" in this chapter.

n 5-2

To remove the cable, grasp the connector and gently pull it from the port. DO NOT pull on the cable.

Page 37

Chapter 5. Transferring Data

Receiving Data ––––––––––––––––––––––––––––––––––––––––––––– Follow these steps before you begin to receive data from your host (such as an application).

n

Remember, your application may already be in the printer and you may not have to download any files. 1. From the MAIN MENU, press > until you see: Start App. Data Transfer 2. Press e. You will see: TRANSFER MENU Receive 3. Press e. You will see: WAITING 4. Send the data from the host. You may see messages on the printer’s display as data is received. 5. When you complete the transfer... F n

If your application begins automatically, disconnect the cable from the printer.

Make sure you grasp the connector when removing the communications cable. DO NOT pull on the cord. F

If you see WAITING, you will need to start your application.

a. Disconnect the cable from the printer.

n

Make sure you grasp the connector when removing the communications cable. DO NOT pull on the cord.

5-3

Page 38

6030 Operator’s Handbook b. Press b two times. You will see: Start App. Data Transfer c. Press <. You will see: Resume App. Start App. d. Press e.

Sending Data––––––––––––––––––––––––––––––––––––––––––––––– You can send data collection records and up to 10 lookup tables to a host. Follow these steps before you send records to your host. 1. From the MAIN MENU, press > until you see: Start App. Data Transfer 2. Press e. You will see: TRANSFER MENU Receive 3. Press > until you see: Receive Send 4. Press e. You will see: SEND MENU Data Collect 5. Select the records you want to send to the host. 5-4

Page 39

Chapter 5. Transferring Data

F

Press e to send data collection records.

-ORF

Press > to select a Lookup Table (1-10) to send to the host, and then press e. Each time you successfully transmit records, you will see TRANSMISSION COMPLETE.

6. When you are finished sending data: a. Press b until you see the MAIN MENU. b. Disconnect the cable from the printer.

n

Make sure you grasp the connector when removing the communications cable. DO NOT pull on the cord.

Setting Communications Parameters –––––––––––––––––––––––––– You can use the Serial Port menu in the Command mode to F set the communications parameters to match your host.

F enable/disable the echo of the BEL character.

F enable/disable ENQ polling (status polling).

To set these parameters: 1. From the MAIN MENU, press > until you see: Start App. Data Transfer 2. Press e. You will see: TRANSFER MENU Receive

5-5

Page 40

6030 Operator’s Handbook 3. Press > until you see: Send Serial Port 4. Press e. From this point, you can set the following communications parameters:

n

Baud Rate

19.2K, 9600*, 4800, 2400, 1200

Parity

NONE, EVEN, ODD*, MARK, SPACE

Data Bits

7*, 8

Stop Bits

1*, 2

Flow Control

NONE, XON/XOFF*, DTR, RTS, MODEM

Echo BEL

Enable*, Disable

ENQ Polling

Enable, Disable*

Resp Timeout

30* (seconds), 0 (minimum), 480 (maximum)

Echo BEL, ENQ Polling and Response Timeout are all options used by the application or set by the System Administrator. 5. Press < or > to display a parameter and press e to select it. 6. Press < or > to display a value and press e to select it.

* Factory set defaults.

5-6