Page 37

'Set up data str eam CmdString = ESC & "P#" & CRLF & CRLF CmdString = CmdString & " Paxar/Monarch" & CRLF CmdString = CmdString & " 170 Monarch Ln." & CRLF CmdString = CmdString & " Miamisburg, OH 45342" & CRLF CmdString = CmdString & " Phone: (937) 865-2123" & CRLF & CRLF CmdString = CmdString & " SALES RECEIPT" & CRLF & CRLF CmdString = CmdString & "Description Qty. Total" & LF CmdString = CmdString & "1.Monarch 9490 5 3495" & LF C m d S t r i n g = C m dString & "2.Monarch 9403 4 995" & LF CmdString = CmdString & "3.Monarch 6035 3 4995" & LF CmdString = CmdString & "4.Monarch 6030 2 2995" & LF CmdString = CmdString & "5.Monarch 9450 1 995" & LF CmdString = CmdString & " -----" & LF CmdString = CmdString & " Total 13475" & CRLF & CRLF CmdString = CmdString & "AMEX 37xvz55xx315001" & LF CmdString = CmdString & "Exp. Date 10/01" & CRLF & CRLF & CRLF CmdString = CmdString & ESC & "z1" & Char(6) & Chr(64) & "123456" CmdString = CmdString & LF & Chr(12) CmdString = CmdString & "" & LF CmdString = CmdString & "" & LF 'Allocate the port iSerialPort = SerialPortAllocate() iReturn = SerialPortOpenText(iSerialPort , 0, 19200, CRLF, CRLF) iReturn = SerialPortConfigure(iSerialPort,19200,8,"None",1,"Hardware") BufferSize = 512 + 32 'Allocate buffer Buffer = MemoryAllocate(BufferSize) iReturn = SerialPortSetBuffer(iSerialPort, Buffer, BufferSize) 'Send data stream iReturn = SerialPortWriteString(iSerialPort, CmdString) While Byte <> NAK 'Wait for response Byte = SerialPortReadString(iSerialPort, 1) if Byte = NAK then exit while String = String & Byte Wend MsgBox(String)

Sample Application A-3

Page 38

Buffer = MemoryFree(Buffer) iReturn = SerialPortClose(iSerialPort) iReturn = SerialPortFree(iSerialPort)

'Deallocate the port

LPrint(Chr(12)) MsgBox("Done") If ClosePort() = false then MsgBox("Close Failed") EndIf

'Form feed 'Finish up

A-4 Sample Application

Page 39

INDEX A application, sample, A- 1 B commands bar code field creation, 2- 7 bar code scanner, 6- 2 battery voltage checking, 3- 2 bar code character set selection, 2- 2, 4- 3 fields, creating, 2- 7 scanner, using, 6- 1 specifying particular, 2- 8 types available, 2- 8 battery voltage, checking, 3- 2 black mark supplies, 3- 5 buffer mode, 3- 1 data stream graphic, 2- 4 field positioning, 2- 10 flash memory graphic, 2- 6 formatting text, 2- 2 handheld communication, 3- 7 loading new characters, 4- 4 magnetic card reader, 5- 1

C character miscellaneous control characters, 3- 8 operating mode selection, 3- 1 defining new, 4- 2 power mode setting, 3- 2 exceptions, 2- 2 power- off timer, 3- 4 loading new, 4- 4 print contrast setting, 3- 1 sets, selecting (creating text fields), 2- 2 supply control, 3- 5 sets, selecting (font modification), 4- 3 checking battery voltage, 3- 2 print buffer status, 3- 3 version information,3- 6 Codabar bar codes, 2- 8 Code 128 (UCC/EAN- 128 bar codes, 2- 9 Code 39 bar codes, 2- 8 version information checking, 3- 6 communicating with handheld, 3- 7 communication parameters, 3- 7 configuring printer, 3- 1 contrast, print, 3- 1 control characters, miscellaneous, 3- 8 control of supplies, 3- 5 conventions in manual, 1- 2 Index-1

Page 40

creating formats bar code fields, 2- 7 definition, 2- 1 formats, 2- 1 printing and creating, 2- 1 graphic fields, 2- 3 formatting text, 2- 2 text fields, 2- 1

G D graphics data stream graphics, 2- 4 data stream, 2- 4 defining new characters, 4- 2 fields, 2- 3 duty cycle, 1- 1 flash memory, 2- 5 E

H errors, magnetic card reader, 5- 3 handheld, communicating with, 3- 7 exceptions, character, 2- 2 hardware version, 3- 6

F fields

I initialization of printer, 3- 8 bar code, 2- 7

Interleaved 2 of 5 bar codes, 2- 8 definition, 2- 1 introduction, 1- 1 graphic, 2- 3 positioning, 2- 10

L loading new characters, 4- 4 text, 2- 1

M firmware version, 3- 6 flash memory graphics, 2- 5 fonts modified, 4- 4 resident, 4- 1 sizes, 4- 1

Index-2 magnetic card reader errors, 5- 3 using, 5- 1 manual, conventions in, 1- 2

Page 41

selecting mode character sets (creating text fields), 2- 2 buffer, 3- 1 online, 3- 1 character sets (font modification), 4- 3 operating, 3- 1 operating mode, 3- 1 power, 3- 2 modifying resident fonts, 4- 1 O setting power mode, 3- 2 print contrast, 3- 1 online mode, 3- 1 sizes of fonts, 4- 1 operating mode, selecting, 3- 1 status, print buffer, 3- 3

P supplies, black mark, 3- 5 T positioning fields, 2- 10 power mode, setting, 3- 2 text power- off timer, using, 3- 3 fields, creating, 2- 1 print buffer status, checking, 3- 3 formatting, 2- 2 print contrast, setting, 3- 1 timer, power- off, 3- 3 printer

U configuring, 3- 1

UPC/EAN/JAN bar codes, 2- 8 initialization, 3- 8 supply control responses, 3- 6 printing formats, 2- 1 R using bar code scanner, 6- 1 data stream graphics, 2- 4 flash memory graphics, 2- 5 resident fonts, modifying, 4- 1 magnetic card reader, 5- 1 responses (supply control), 3- 6 power- off timer, 3- 3

S

V sample application, A- 1 version information, checking, 3- 6 saving modified fonts, 4- 4 voltage, battery, 3- 2 scanner, bar code, 6- 1 Index-3

Page 42

Index-4

Page 43

This page is a scan with no text; see it in the PDF.

Page 44

For supplies, service, or assistance call toll free: 1-800-543-6650 (In the U.S.A.) 1-800-263-4650 (In Canada) www.monarch.com