Page 81
Option 20 (Define Data Entry Prompts) This option defines the operator prompt. This option is not recommended on fields filled entirely by fixed characters or copied data. Option 20 is only available on the 9403 printer. This option must be defined before Option 5, or the prompt will not display during data entry. Syntax
R,20,"prompt" p
R1. R
Option Header.
R2. 20
Option 20.
R3. "prompt"
Displays the exact phrase you want to prompt the operator. Must be enclosed within quotations. The prompt should be 15 characters or fewer.
Example
R,20,"Order Number" p
Displays the prompt "Order Number" for the operator when this field is imaged.
5-10 Defining Field Options
Page 82
Option 30 (Padding Data) You can add characters to one side of a field to "pad" the field. Padding allows you to fill in the remaining spaces when the entered data does not fill an entire field. If a variable length field is not completely filled with batch data, this option fills the remaining positions in the field with the character designated by Option 30. Syntax
R,30,L/R,"character" p
R1. R
Option Header.
R2. 30
Option 30.
R3. L/R
Indicates type of padding
R4. "character"
L
Pad field on left side
R
Pad field on right side
Pad character must be within the 0 - 255 decimal range and enclosed inside quotation marks. NOTE: Do not use on fixed length fields.
Example
R,30,L,"X" p
Pads data with an "X" on the left side of the field.
Sample Use for Pa dding If you have a variable length bar code that you want to occupy a fixed amount of space on the supply, use pad characters. If the maximum number of characters in the bar code is 15, but the batch record only has 10 characters, the padding option fills the remainder of the field with pad characters.
Defining Field Options 5-11
Page 83
Option 31 (Calculate Check Digit) The printer generates a check digit if you apply Option 31 to the field. You cannot use this option if the field contains a UPC, EAN, or Code 39 (with the MOD43 check digit) bar code. Syntax
R,31,gen/ver,check digit # p
R1. R
Option Header.
R2. 31
Option 31.
R3. gen/ver
Enter G to generate a check digit.
R4. check digit # Specifies a check digit scheme. Enter a number that identifies a check digit scheme that has been defined. For more information, see "Using Check Digits." Range: 1 - 10.
Example
R,31,G,5 p
Generates a check digit using the previously defined check digit scheme 5.
5-12 Defining Field Options
Page 84
Option 42 (Price Field) You can apply options that will insert monetary symbols automatically. Do not use this option with Option 31 (define a check digit) or Option 60 (increment or decrement a field). This option is not recommended for bar codes. When determining the maximum number of characters, add the maximum number of digits and the monetary symbols. Syntax
R,42,appearance code p
R1. R
Option Header.
R2. 42
Option 42.
R3. appearance code
Enter 1 to print price field in standard notation, as defined by country setting. Use the monetary formatting packet to select monetary notations and symbols by country setting. See "Defining the Monetary Formatting Packet" for more information. See Appendix C, "Symbol Sets/Code Pages," to make sure the monetary symbol you want to use is printable in the font selected for this field. For monetary symbols other than the dollar sign, use the internal symbol set.
Example
R,42,1 p
Uses a price field that prints the monetary symbol and notations as defined in the monetary formatting packet.
Defining Field Options 5-13
Page 85
Option 50 (Bar Code Density) You can apply this option to bar code fields when you want to create custom densities. When you apply this option, it overrides the density value in the bar code field. When using this option, set the density parameter in your bar code field to the default value. You can only use this option once for each bar code field. This option overrides the density selected in the bar code field. Bar codes produced using Option 50 may not be scannable. The additional character gap, narrow space, and wide space parameters are valid only with Code 39 and Codabar. If these parameters are specified for any other bar codes, they will be ignored by the printer. Do not use Option 50 with fixed density bar codes. Syntax
R,50,narrow,wide,gap,nar_space,wide_space p
R1. R
Option Header.
R2. 50
Option 50.
R3. narrow
Dot width of the narrow element. (Code 39 and Codabar only). Range: 1-99.
R4. wide
Dot width of the wide element. (Code 39 and Codabar only). Range: 1-99.
R5. gap
Additional dot space between characters. Enter a value of 1 to 99. (Code 39 and Codabar only.)
R6. nar_space
Additional dot width of the narrow bar code space. (Code 39 and Codabar only). Range: 1- 99.
R7. wide_space
Additional dot width of the wide bar code space. (Code 39 and Codabar only). Range: 1- 99.
Example
R,50,4,8,5,1,1 p
Creates a custom bar code density with a narrow element of 4 dots, a wide element of 8 dots, a gap of 5 dots, and one additional dot width for the narrow and wide bar code space (if this is a Code 39 or Codabar bar code). 5-14 Defining Field Options
Page 86
O p t i o n 5 1 ( P D F 4 1 7 S e c u r i t y / Tr u n c a t i o n ) You can define a security level and choose whether or not to truncate a PDF417 bar code. Higher security levels add data to a bar code, improving scan reliability. Some damaged bar codes may still be scannable if the security level is high enough. You can use this option to create standard PDF417 bar codes or use the truncated option to create a narrower bar code. This option can appear only once per PDF417 field, in any order, following the bar code field. As the security level is increased, so is the size of your PDF417 bar code. For each level increased, the bar code will double in size. Option 51 is not available on the 9820 printer. Syntax
R,51,security,stand/default p
R1. R
Option Header.
R2. 51
Indicates Option 51.
R3. security
Security level ranges from 0-8 (0 is the default). Higher security levels add data to a bar code, improving scan reliability. Some damaged bar codes may still be scannable if the security level is high enough.
R4. stand/def
Truncation selector. Valid values: S T
Example
(default) a standard PDF417 bar code truncated
R,51,2,S p
Defines a security level of 2 for a standard PDF417 bar code.
Defining Field Options 5-15
Page 87
Option 52 (PDF417 Width/Length) This option defines the image width or length of a PDF417 bar code. If you define a fixed number of columns (width), the bar code expands in length. If you define a fixed number of rows (length), the bar code expands in width. Column value does not include start/stop or left/right indicator columns. If this option does not immediately follow the PDF417 bar code field, the default settings are used. You can only use this option once per PDF417 bar code field. Option 52 is not available on the 9820 printer. Syntax
R,52,row/column,dimension p
R1. R
Option Header.
R2. 52
Indicates Option 52.
R3. row/column
Indicates if you are defining the number of rows or columns. R C
Row Column
If you specify rows, the bar code expands in columns, or vice versa. R4. dimension
The number of rows or columns defined for the bar code. The default is 4. Valid values: 3-90 for rows 1-30 for columns
Example
R,52,C,10 p
Defines the column width of 10, which expands the PDF417 bar code length by 10.
5-16 Defining Field Options
Page 88
Option 60 (Incrementing/Decrementing Fields) You may have an application, such as serial numbers, in which you need a numeric field to increment (increase in value) or decrement (decrease in value) on successive tickets within a single batch. Incrementing or decrementing can be applied to numeric data only. If you have a field that includes letters and digits, apply incrementing or decrementing to only the portion of the field that contains digits. Do not use with Option 42 (price field). Syntax
R,60,I/D,amount,l pos,r pos p
R1. R
Option Header.
R2. 60
Option 60.
R3. I/D
I D incrementing field decrementing field
R4. amount
Amount to increase or decrease. Range: 0- 999.
R5. l pos
Leftmost position in inc/dec portion of field. If this value is not entered, the default value 1 is used. Range: 0 - 2710 (1 100 for 9403).
R6. r pos
Rightmost position in inc/dec portion of field. If this value is not used, the entire field length is used as the default. Range: 0 - 2710 (1 - 100 for 9403).
Example
R,60,I,5,1,6 p
Increments a field by 5 each time the field is printed. The field increments beginning with the first left position and ending with the sixth position.
Fixing the First Number in the Incrementing Sequence There are two ways to enter the first number in the incrementing sequence. You can use batch data or use Option 1 to define the first number as a fixed character.The first number in the sequence must contain the same amount of digits as the highest number to be counted. For example, to count the numbers 1 to 999, the first number in the sequence must be entered as 001. Defining Field Options 5-17
Page 89
Option 61 (Reimage Field) This option redraws (reimages) a constant field when you have a constant field next to a variable field on your label. It can be used on text, constant text, bar code, line, or box fields. These printers do not redraw an area if the field data does not change. When a field changes, that area is cleared and the new field data is imaged. However, the new field data may require a larger area than the previous field did. In some cases, neighboring fields that do not change (constant fields) may be covered with white space from the changing field’s (variable fields) area. Use this option to reimage the constant field, or it may appear broken. The most common use for this option is with incrementing fields on your label, because they may cover a constant field. Syntax
R,61 p
R1. R
Option Header.
R2. 61
Option 61.
Example
R,61 p
Reimages the constant field that appears next to a variable field.
Re-Image ON
Re-Image OFF
In the above example, Option 61 was applied to the bar code field to keep the incrementing field (Box #) from blocking out the bar code field. 5-18 Defining Field Options
Page 90
Using Check Digits Check digits are typically used to ensure that a text or bar code field scans correctly. If you apply Option 31, the printer calculates a check digit. A check digit scheme determines how the printer calculates a check digit. When you define a check digit scheme, you assign a number to identify it. This number is later entered in box R4 when you apply Option 31 to a field. You can use check digits with text or bar code fields. Check digit calculations are performed on numeric data only. Do not use check digits with price fields. Do not define a check digit scheme for these bar codes, because they have predefined check digits: UPC, EAN, Code 39 (with the MOD43 check digit), and Code 93. Syntax
{A,selector,action,device,modulus, fld_length,D/P,"weights" p }
A1. A
Check Digit Header.
A2. selector
Assign a number from 1-10 to this check digit formula.
A3. action
Adds a check digit scheme. Enter A.
A4. device
Device. Use R.
A5. modulus
Number from 2-11. The modulus is used to divide the sum of products or the sum of digits.
A6. fld_length
The maximum number of characters the field will contain. Range: 0 - 2710 (0 - 100 for 9403).
A7. D/P
Algorithm. The algorithm determines how the check digit is calculated. Options: D P
A8. "weights" sum of digits sum of products
String of digits used for calculation. A weight string is a group of two or more numbers that is applied to a field. The number of digits in this string should equal the number in fld_length. Enclose in quotation marks. Range: 0 - 2710 (0 - 100 for 9403).
Defining Field Options 5-19