Page 11
When designing formats, keep in mind the following non-print zones for the 9403 printer: Bottom Left
.035 inches at the beginning of the label. .10 inches from the left edge of the label.
The following non-print zones are recommended for the 9800 series printers: Butt Cut Supplies All Supplies All Supplies
.150 inches at the beginning of the label. .050 inches on either edge of the label. .020 inches at the end of the label.
Use the following formulas to convert inches to dots and metric: Dots = inches x 203 Metric (1/10mm) = inches x 254 English (1/100 inch) = 100 x (dots/203) Dots = Metric (1/10 mm) x 799/1000
Drawing Rough Sketches After you decide what information you want to print, sketch how you want the information to appear on the label. Note any areas that are preprinted on the label, such as a logo. As soon as you know what information to include on the label, and you have a rough sketch, you can use a supply layout grid to help you layout and size your label. If you do not want to use a grid, go to "Considering Field Types" to choose what information you want on your label.
2-4 Designing a Format
Page 12
Using Supply Layout Grids A supply layout grid contains measurement markers. These markers help you accurately position information on your label. Decide whether you want to design formats using English, Metric, or Dot measurements. Choose from the following grids: u
English The English grid, shown to the right, is measured in 1/100 inches.
u
Metric The Metric grid is measured in 1/10 millimeters (mm).
u
Graphic The printer uses dots to print images on a label. The printhead has 203 dots per inch (DPI).
192
Supply Layout (dpi)
203
1536
1624
1440
1523
1344
1421
1248
1320
1152
1218
1056
1117
960
1015
864
914
768
812
672
711
576
609
480
508
384
406
288
305
192
203
96
102
0.0
192 0.0 203 0.0
0.0 96 102
192 203
288 305
384
480
576
672
768 806
406
508
609
711
812 853
Choose English or Metric units when designing formats to use with different printers. English or Metric units allow more direct use of formats on printers with different density printheads. If you want to use supply layout grids, a copy of each is in Appendix D, "Format Design Tools."
Designing a Format 2-5
Page 13
C o n s i d e r i n g F i e l d Ty p e s After you select a supply size, the next step in designing a format is to decide what information you want to print on the label. For example, you may want to print your company name, price of an item, and a bar code that combines information from other places. Everything you want to print falls into one of the following categories. Field Type
Description
Examples
Text
Contains letters, numbers, or symbols you want to print.
item number, item description, department number, price, date
Non-Printable Text
Holds data for use later, such as for merging into another field. The printer does not print non-printable text fields.
city, state, and zip code to be included in a bar code
Bar Code
Used for printing bar codes that can be scanned.
item or serial numbers, zip codes, information you don’t want to have visible to customers
Constant Text
Prints fixed characters that print without changing.
company name, company address
Line or Box
Highlights or separates items.
line marking out the regular price, border around the supply
Graphic
Contains a bitmap image or a compliance label overlay.
logos
All of the above field types except graphics are discussed in Chapter 4. See Chapter 6, "Creating Graphics," for information on including graphics in your format.
2-6 Designing a Format
Page 14
Considering Fonts When working with fonts, you have three considerations: u font appearance u font size (scalable or bitmapped)
u font spacing (monospaced or proportional)
The scalable font, CG Triumvirate Bold is standard on the 9830 and 9835 printers. It is not available for the 9403 or 9820 printer. See Appendix B, "Fonts," for samples of each font.
Interchanging Packets You can use an MPCLII format that was designed for another MPCLII printer on a 9800 series printer. However, the format may appear smaller (fields will be shorter), because the 9800 series printers use a 203 DPI printhead. Some other MPCLII printers use a 192 DPI printhead.
U s i n g t h e F o r m a t Wo r k s h e e t The Format Worksheet is divided into sections that list the field types. Each section has boxes to fill in with parameters that define your format. A format worksheet is included in Appendix D, "Format Design Tools."
F i l l i n g i n t h e Fo r m a t Wo r k s h e e t Decide what type of field to use on your label. 1. Make a copy of the Format Worksheet. 2. Define the Format Header. 3. Define all non-printable text fields before you define the ones you want to print. See "Defining Non-Printable Text Fields" in Chapter 4 for more information.
Designing a Format 2-7
Page 15
4. Define options as you require them. See Chapter 5, "Defining Field Options" for more information.
2-8 Designing a Format
Page 16
CONFIGURING THE PRINTER
3
This chapter discusses how to u set communication parameters.
u upload the printer’s configuration or font information.
u configure the printer using online configuration packets.
u use immediate commands to control the printer’s operation at any time.
Some parameters may not be available on this printer. See Appendix E, "Printer Differences," for a list of differences between a 9820 printer and a Monarch® 9446 printer.
Configuring the Printer 3-1
Page 17
Setting Communication Parameters Use the following information if you are using serial communications. See "Using Parallel Communications" for information about parallel communications. Not all printers have a parallel port. The communication parameters at the printer must match those at the host, or you will not be able to communicate. You can use the communication settings packet or DIP switches to set communication parameters for your printer. Not all printers have DIP switches. On MS-DOS computers, you can use the MODE command to set communication values on your PC. For example MODE COM1:9600,N,8,1 This command sets your host to these communication values: u a baud rate of 9600 u no parity u
8 bit word length u
1 stop bit
3-2 Configuring the Printer
Page 18
Using Parallel Communications If your printer supports parallel communications, the parallel port is IEEE-1284 or Centronics® mode. You can set which mode to use by changing a DIP switch. Refer to your Operator’s Handbook for DIP switch settings. The communication settings are automatically configured for you. There are no operator settings required.
Using Autobaud You can use the autobaud feature to automatically set the printer’s baud rate, parity, data bits, and stop bits to match the host’s. Autobaud overrides the DIP switch settings and the values in the communication settings packet. Do not send any data to the printer before using autobaud. To use autobaud, you must: 1. Power up the host first and then turn on the printer. Autobaud only works during the initial power up. Wait 2 to 5 seconds. 2. After the 9800 series printer’s power LED comes on (or the 9403 printer displays "Print Mode READY"), send a sequence of 32 alternating @A characters (for a total of 64 characters) to the printer. Example
@A@A@A@A@A@A@A@A@A@A@A@A@A@A@A@A@A@A @A@A@A@A@A@A@A@A@A@A@A@A@A@A
Do not use character pacing (delay for each character) or any other delay while sending the autobaud sequence. Wait one second after sending the autobaud sequence before sending any commands (including setting flow control) or data to the printer. During this time, the hardware is being changed to the new settings.
Configuring the Printer 3-3
Page 19
3. To select flow control and finalize communications, send the communication settings packet. Or, use the Optional Entry method described in Chapter 7, "Printing." Example
{I,F,,,,,3 p }
This packet sets the flow control parameter to XON/XOFF, without changing the current communication settings established with Autobaud.
Using MPCLII Conventions Here are some guidelines to follow when using MPCLII.
MPCLII Punctuation Use the following symbols when creating MPCLII packets: { start of header
} end of header p field separator
, parameter separator
"ABC"
Quotation marks enclose character strings. Empty quotes ("") identify null strings or unused fields.
‘comment‘
Grave accents enclose comments. Any data enclosed in grave accents is ignored. Do not embed comments within a quoted string. ENQ and immediate commands are always processed, even if they are included within grave accents Grave accents are also used to reject mainframe data.
These MPCL characters are the default. See "Defining the Control Characters Packet" to change these characters.
3-4 Configuring the Printer
Page 20
Standard Syntax Guidelines When creating MPCLII packets: u
Begin each packet with a start of header ({).
u
End each packet with an end of header (}).
u
Define no more than 1000 fields (100 fields for 9403 printer) in a format. Each p indicates one field. However, options are not counted as fields. The actual number of fields a format can have may be less, because the number of fields is limited by the available memory.
u
The field number 0 to 999 (99 for the 9403 printer) must be unique. Monarch recommends starting at 1, instead of 0.
u
Do not use a field number more than once per format.
u
Define all fields in the order you want to image/print them. The printer does not print in field number order.
u
Separate all parameters with a Parameter Separator (,).
u
End each field with a Field Separator ( p ).
u
Enter all information in CAPITAL letters, except words or phrases within quotation marks.
u
Include all parameters for a field unless documented as optional.
u
Define non-printable text fields before the field to which they apply.
u
Define options immediately after the field to which they apply.
u
Multiple options can be used with most fields. Options can be used in any combination except as noted with each definition. When using multiple options on the 9403 printer, remember that options are processed in the order they are received.
u
Keep in mind that proportionally spaced fonts need wider fields than monospaced fonts. For variable field data, use a letter "W" to determine the maximum field size.
Configuring the Printer 3-5