Page 121
013
Column field position is greater than the maximum stock dimension. See "Defining Text Fields" in Chapter 4 for valid column widths.
014
Font style must be 1, 2, 3, 4, 10, or 11. See "Defining Text Fields" in Chapter 4 or Appendix B, "Fonts," for more information.
015
Character rotation must be 0 (0 degree), 1 (90 degree), 2 (180 degree), or 3 (270 degree). See "Defining Text Fields" in Chapter 4 for information.
016
Field rotation must be 0 (0 degree), 1 (90 degree), 2 (180 degree), or 3 (270 degree). See "Defining Text Fields" in Chapter 4 for information.
017
Field restriction must be V (variable) or F (fixed).
018
Code page selection defined in the field must be 0 (Internal), 1 (ANSI), 2 (DOS 437), or 3 (DOS 850).
020
Vertical magnification must be 1 to 7.
021
Horizontal magnification must be 1 to 7.
022
Color must be B, D, O, R, or W. See "Defining Text Fields" in Chapter 4 for more information.
023
Intercharacter gap must be 0 to 99 dots.
024
Field justification must be B (balanced), C (centered), E (end), L (left), or R (right). See "Defining Text Fields" in Chapter 4 for more information.
025
String length is outside the range 0 to 2710.
Errors 9-3
Page 122
030
Bar code height must be at least 20 (English), 51 (Metric), 40 (Dots), or is not within the supply dimensions.
031
Human readable option must be 0 1 5 6 7 8
9-4 Errors default no CD or NS NS at bottom, no CD CD at bottom, no NS CD and NS at bottom no text
032
Bar code type is invalid. See "Defining Bar Code Fields" in Chapter 4 for valid options.
033
Bar code density is invalid. See "Defining Bar Code Fields" in Chapter 4 for the bar code density chart.
040
Line thickness must be 0 to 99 dots.
041
Line direction must be 0, 90, 180, or 270.
042
End row is invalid. Line segment or box end row is defined outside of printable area.
043
End column is invalid. Line segment or box end column is defined outside of printable area.
044
Dot pattern for line or box must be "".
045
Line length is defined beyond the maximum length. See "Defining Line Fields" in Chapter 4 for valid lengths.
046
Line type must be S (segment) or V (vector).
051
Imaging mode in the graphic header must be 0.
101
The format referenced by batch is not in memory.
102
Print quantity is outside the range 0 to 32000.
Page 123
104
Batch mode must be N (new) or U (update).
105
Batch separator must be 0 (Off), 1 (On), 2 (Double) in the batch control field.
106
Print multiple is outside the range 1 to 999.
107
Cut multiple is outside the range 0 to 999. Not valid for these printers.
108
Multiple part supply is outside the range 1 to 5.
109
Reserved for knife usage. Not valid for these printers.
200
Option number must be 1, 4, 30, 31, 42, 50, 51, 52, 60, or 61.
201
Copy length is outside the range 0 to 2710.
202
Copy start position must be 1 to 2710.
203
Destination start position must be 1 to 2710.
204
Source field must be 0 to 999.
205
Copy type must be 1 (copy after rules) or 2 (copy before rules).
206
Increment/Decrement selection must be I (increment) or D (decrement).
207
Incrementing start position must be 0 to 2710.
208
Incrementing end position must be 0 to 2710.
209
The incrementing amount must be 0 to 999.
210
Security value for a PDF417 bar code must be 0 to 8. Correct the value and resend the format to the printer.
211
Narrow element value is less than 1 or greater than 99. Correct the value and resend the format to the printer.
Errors 9-5
Page 124
9-6 Errors
212
Wide element value is less than 1 or greater than 99. Correct the value and resend the format to the printer.
213
Dimension must be 1 to 30 for a column or 3 to 90 for a row on a PDF417 bar code.
214
Truncation code must be S (standard) or T (truncated bar code).
215
Aspect code must be C (columns) or R (rows).
216
Option definition must be S (set) or T (template).
217
Input device device must be D (Default), H (Host), K (Keyboard), N (None), or S (Scanner).
218
Pad direction must be L (from left) or R (from right).
219
Pad character is outside the range 0 to 255.
220
Check digit selection must be G to generate check digit.
221
Primary or secondary price format is outside the range 1 to 15.
222
Data type restriction is outside the range of 1 to 6.
223
Option is not valid for the field.
224
Bar code Intercharacter gap must be 0 to 99 dots. (This is also known as the additional character gap when using Option 50, Defining Bar Code Densities.)
251
Power up mode must be 0 (online).
252
Language selection must be 0 (English).
253
Batch separator code must be 0 (off), 1 (on), or 2 (Double) in the System Setup Packet.
254
Slash zero selection must be 0 (standard zero) or 1 (slash zero).
Page 125
255
Supply type must be 0 (black mark), 1 (die cut), or 2 (non-indexed).
256
Ribbon selection must be 0 (direct) or 1 (transfer).
257
Feed mode must be 0 (continuous) or 1 (on-demand).
258
Supply position is outside the range. See "Defining the Supply Setup Packet" in Chapter 3 for more information.
259
Contrast adjustment must be -390 to 156 dots.
260
Print adjustment must be -99 to 99 dots.
261
Margin adjustment must be -99 to 99 dots.
262
Speed adjustment must be 0 (default) or 20 (2.0 IPS).
263
Primary monetary symbol is invalid. See "Defining the Monetary Formatting Packet" in Chapter 3 for more information.
264
Secondary symbol selection must be 0 (none) or 1 (print secondary sign).
265
Monetary decimal places must be 0 to 3.
266
Character string length in the control characters packet must be 5 (MPCL control characters) or 7 (ENQ/IMD command character).
267
Baud rate selection must be 0 (1200), 1 (2400), 2 (4800), 3 (9600), 4 (19200), or 5 (38400). Resend the communication settings packet or check the DIP switch settings.
268
Word length selection must be 0 (7 bits), or 1 (8 bits). Resend the communication settings packet or check the DIP switch settings.
Errors 9-7
Page 126
9-8 Errors
269
Stop bits selection must be 0 (1 bit), or 1 (2 bits). Resend the communication settings packet or check the DIP switch settings.
270
Parity selection must be 0 (none), 1 (odd), or 2 (even). Resend the communication settings packet or check the DIP switch settings.
271
Flow control selection must be 0 (none), 1 (DTR), 2 (CTS/RTS), or 3 (XON/XOFF). Resend the communication settings packet or check the DIP switch settings.
272
Internal code page selection must be 0 (Internal), 1 (ANSI), 2 (DOS 437), or 3 (DOS 850).
273
Cut adjustment must be -300 to 300 dots.
282
RS232 Trailer string is too long. Use a maximum of 3 characters.
283
ENQ Trailer string is too long. Use a maximum of 3 characters.
284
The buffer type must be T (Transmit), R (Receive), I (Image), F (Format), or D (Downloadable Fonts).
285
The storage device type in the memory configuration packet must be N (non-volatile RAM).
286
The buffer size is invalid.
287
The printhead width must be 0.
288
The battery voltage must be 0 (15-volt battery) or 1 (12-volt battery).
289
The printer address specified in the communication settings packet must use exactly six characters.
Page 127
290
Action must be 0 (disable) or 1 (enable) for the backfeed control packet or the printer is active.
291
Dispense position must be 50 to 200 dots and the backfeed distance is greater than the dispense position or the printer is active.
292
Backfeed distance must be 10 to 200 dots or the printer is active.
310
Check digit scheme number must be 1 to 10.
311
Modulus must be 2 to 11.
314
Check digit algorithm must be D (sum of digits) or P (sum of products).
325
Duplicating direction must be 0 (insert after) or 1 (insert before) in duplicate fields for graphics.
327
Amount of row adjustment must be 0 to 999 (0 to 99 for 9403) dots in duplicate fields for graphics.
328
Duplicate count must be 0 to 999 (0 to 99 for 9403).
340
Bitmap line encoding must be H (hex) or R (run length).
350
Font selector must be 1 to 9999.
351
Font data length must be 68 to 16384.
352
Insufficient font memory is available for the downloaded font.
380
Job request is outside the range 0 to 4.
400
The character immediately following { is invalid.
402
Field separator is not in the expected location.
403
Field separator was not found.
Errors 9-9
Page 128
404
The number or string that is currently being processed is too long.
405
Too many fields exist in the format. You cannot have more than 1000 fields in the format. Lines, boxes, and constant text fields count as fields.
409
The printer memory is full. Delete unnecessary formats or graphics from memory. If you are using a graphic file that is very large, consider using another mapping method (such as run length encoding) to reduce the required memory.
Communication Failures Errors 410 to 413 are usually caused by a hardware failure, by an incorrect SETUP option or by the host ignoring flow control (XON/OFF, CTS/RTS or DTR). Communication settings: Baud rate Word length Stop bits Parity Flow control
9-10 Errors
1200, 2400, 4800, 9600, 19200, 38400 7 or 8 1 or 2 Odd, Even, None None, XON/XOFF, DTR, CTS
410
Parity on the printer does not match the parity on the host. Check the parity setting under SETUP options.
411
Framing error. The printer cannot communicate with the host. Make sure the host is turned on, communication cables are connected correctly, port settings are correct, and communications are active. Check the baud rate, word length, and stop bits to make sure they match those at the host. Do not toggle between Microsoft® Windows® and MS-DOS, while using the COPY command, or you will receive a framing error. Exit Windows before using the COPY command. Re-transmit the data.
Page 129
412
There is a problem with flow control between the printer and the host. Make sure the printer and the host flow control settings match (both are DTR or both are XON/XOFF). If the error persists, call Technical Support.
413
Online receive queue is full. Check your printer’s XON/XOFF or DTR SETUP values to be sure there isn’t a flow control problem.
414
The internal keyboard buffer is full or you need a new keypad. Call Technical Support.
415
The buffer size you defined exceeds the total available in your machine.
416
Flash/PC board error. Call Technical Support.
417
Flash memory is full. Clear flash through the 9403 printer’s menu. Resend the format, graphic, and check digit packets. If the error reappears, call Technical Support.
427
Format name is invalid. Valid name is 1 - 8 characters inside quotes or "" for a printer-assigned name. Press the FEED button and try to continue. If the error reappears, call Technical Support.
428
Batch name is invalid or graphic not found. Press the FEED button and try to continue. If the error reappears, call Technical Support.
429
A field number appears more than once in a format.
430
The format uses a graphic file that cannot be found.
433
The batch references a field number that does not exist in the format.
497
An error occurred during the loop back test on the parallel port. Call Service.
Errors 9-11
Page 130
499
An error occurred during the loop back test on the serial port. Call Service.
Data Formatting Failures Formatting errors indicate that a field will print incorrectly. After you have checked the data stream and corrected the data, retransmit the format and batch. For errors 571-619, the batch will still print, but the field, font, bar code, or density may be incomplete, missing or contain incorrect data.
9-12 Errors
571
UPC or EAN bar code data length is invalid. The bar code data length in the batch does not fit the format.
572
A copy field, padded field, or incrementing field length is invalid. The field length in the batch does not fit the format or the field contains blanks. Or, the fixed length field does not contain the specified number of characters.
573
Price field length is invalid. The price field length in the batch does not fit the format or the field contains blanks.
574
No CD scheme or room for CD. The CD scheme in the batch does not fit the format or the field contains blanks.
575
The graphic included in your format could not be found.
611
Font, bar code or density is invalid. The font, bar code or density in the batch does not fit the format.
612
The data in this line of the batch is either missing or does not match the format.
613
Reference point off tag.