Page 121

013

Column field position is greater than the maximum stock dimension. See "Defining Text Fields" in Chapter 4 for valid column widths.

014

Font style must be 1, 2, 3, 4, 10, or 11. See "Defining Text Fields" in Chapter 4 or Appendix B, "Fonts," for more information.

015

Character rotation must be 0 (0 degree), 1 (90 degree), 2 (180 degree), or 3 (270 degree). See "Defining Text Fields" in Chapter 4 for information.

016

Field rotation must be 0 (0 degree), 1 (90 degree), 2 (180 degree), or 3 (270 degree). See "Defining Text Fields" in Chapter 4 for information.

017

Field restriction must be V (variable) or F (fixed).

018

Code page selection defined in the field must be 0 (Internal), 1 (ANSI), 2 (DOS 437), or 3 (DOS 850).

020

Vertical magnification must be 1 to 7.

021

Horizontal magnification must be 1 to 7.

022

Color must be B, D, O, R, or W. See "Defining Text Fields" in Chapter 4 for more information.

023

Intercharacter gap must be 0 to 99 dots.

024

Field justification must be B (balanced), C (centered), E (end), L (left), or R (right). See "Defining Text Fields" in Chapter 4 for more information.

025

String length is outside the range 0 to 2710.

Errors 9-3

Page 122

030

Bar code height must be at least 20 (English), 51 (Metric), 40 (Dots), or is not within the supply dimensions.

031

Human readable option must be 0 1 5 6 7 8

9-4 Errors default no CD or NS NS at bottom, no CD CD at bottom, no NS CD and NS at bottom no text

032

Bar code type is invalid. See "Defining Bar Code Fields" in Chapter 4 for valid options.

033

Bar code density is invalid. See "Defining Bar Code Fields" in Chapter 4 for the bar code density chart.

040

Line thickness must be 0 to 99 dots.

041

Line direction must be 0, 90, 180, or 270.

042

End row is invalid. Line segment or box end row is defined outside of printable area.

043

End column is invalid. Line segment or box end column is defined outside of printable area.

044

Dot pattern for line or box must be "".

045

Line length is defined beyond the maximum length. See "Defining Line Fields" in Chapter 4 for valid lengths.

046

Line type must be S (segment) or V (vector).

051

Imaging mode in the graphic header must be 0.

101

The format referenced by batch is not in memory.

102

Print quantity is outside the range 0 to 32000.

Page 123

104

Batch mode must be N (new) or U (update).

105

Batch separator must be 0 (Off), 1 (On), 2 (Double) in the batch control field.

106

Print multiple is outside the range 1 to 999.

107

Cut multiple is outside the range 0 to 999. Not valid for these printers.

108

Multiple part supply is outside the range 1 to 5.

109

Reserved for knife usage. Not valid for these printers.

200

Option number must be 1, 4, 30, 31, 42, 50, 51, 52, 60, or 61.

201

Copy length is outside the range 0 to 2710.

202

Copy start position must be 1 to 2710.

203

Destination start position must be 1 to 2710.

204

Source field must be 0 to 999.

205

Copy type must be 1 (copy after rules) or 2 (copy before rules).

206

Increment/Decrement selection must be I (increment) or D (decrement).

207

Incrementing start position must be 0 to 2710.

208

Incrementing end position must be 0 to 2710.

209

The incrementing amount must be 0 to 999.

210

Security value for a PDF417 bar code must be 0 to 8. Correct the value and resend the format to the printer.

211

Narrow element value is less than 1 or greater than 99. Correct the value and resend the format to the printer.

Errors 9-5

Page 124

9-6 Errors

212

Wide element value is less than 1 or greater than 99. Correct the value and resend the format to the printer.

213

Dimension must be 1 to 30 for a column or 3 to 90 for a row on a PDF417 bar code.

214

Truncation code must be S (standard) or T (truncated bar code).

215

Aspect code must be C (columns) or R (rows).

216

Option definition must be S (set) or T (template).

217

Input device device must be D (Default), H (Host), K (Keyboard), N (None), or S (Scanner).

218

Pad direction must be L (from left) or R (from right).

219

Pad character is outside the range 0 to 255.

220

Check digit selection must be G to generate check digit.

221

Primary or secondary price format is outside the range 1 to 15.

222

Data type restriction is outside the range of 1 to 6.

223

Option is not valid for the field.

224

Bar code Intercharacter gap must be 0 to 99 dots. (This is also known as the additional character gap when using Option 50, Defining Bar Code Densities.)

251

Power up mode must be 0 (online).

252

Language selection must be 0 (English).

253

Batch separator code must be 0 (off), 1 (on), or 2 (Double) in the System Setup Packet.

254

Slash zero selection must be 0 (standard zero) or 1 (slash zero).

Page 125

255

Supply type must be 0 (black mark), 1 (die cut), or 2 (non-indexed).

256

Ribbon selection must be 0 (direct) or 1 (transfer).

257

Feed mode must be 0 (continuous) or 1 (on-demand).

258

Supply position is outside the range. See "Defining the Supply Setup Packet" in Chapter 3 for more information.

259

Contrast adjustment must be -390 to 156 dots.

260

Print adjustment must be -99 to 99 dots.

261

Margin adjustment must be -99 to 99 dots.

262

Speed adjustment must be 0 (default) or 20 (2.0 IPS).

263

Primary monetary symbol is invalid. See "Defining the Monetary Formatting Packet" in Chapter 3 for more information.

264

Secondary symbol selection must be 0 (none) or 1 (print secondary sign).

265

Monetary decimal places must be 0 to 3.

266

Character string length in the control characters packet must be 5 (MPCL control characters) or 7 (ENQ/IMD command character).

267

Baud rate selection must be 0 (1200), 1 (2400), 2 (4800), 3 (9600), 4 (19200), or 5 (38400). Resend the communication settings packet or check the DIP switch settings.

268

Word length selection must be 0 (7 bits), or 1 (8 bits). Resend the communication settings packet or check the DIP switch settings.

Errors 9-7

Page 126

9-8 Errors

269

Stop bits selection must be 0 (1 bit), or 1 (2 bits). Resend the communication settings packet or check the DIP switch settings.

270

Parity selection must be 0 (none), 1 (odd), or 2 (even). Resend the communication settings packet or check the DIP switch settings.

271

Flow control selection must be 0 (none), 1 (DTR), 2 (CTS/RTS), or 3 (XON/XOFF). Resend the communication settings packet or check the DIP switch settings.

272

Internal code page selection must be 0 (Internal), 1 (ANSI), 2 (DOS 437), or 3 (DOS 850).

273

Cut adjustment must be -300 to 300 dots.

282

RS232 Trailer string is too long. Use a maximum of 3 characters.

283

ENQ Trailer string is too long. Use a maximum of 3 characters.

284

The buffer type must be T (Transmit), R (Receive), I (Image), F (Format), or D (Downloadable Fonts).

285

The storage device type in the memory configuration packet must be N (non-volatile RAM).

286

The buffer size is invalid.

287

The printhead width must be 0.

288

The battery voltage must be 0 (15-volt battery) or 1 (12-volt battery).

289

The printer address specified in the communication settings packet must use exactly six characters.

Page 127

290

Action must be 0 (disable) or 1 (enable) for the backfeed control packet or the printer is active.

291

Dispense position must be 50 to 200 dots and the backfeed distance is greater than the dispense position or the printer is active.

292

Backfeed distance must be 10 to 200 dots or the printer is active.

310

Check digit scheme number must be 1 to 10.

311

Modulus must be 2 to 11.

314

Check digit algorithm must be D (sum of digits) or P (sum of products).

325

Duplicating direction must be 0 (insert after) or 1 (insert before) in duplicate fields for graphics.

327

Amount of row adjustment must be 0 to 999 (0 to 99 for 9403) dots in duplicate fields for graphics.

328

Duplicate count must be 0 to 999 (0 to 99 for 9403).

340

Bitmap line encoding must be H (hex) or R (run length).

350

Font selector must be 1 to 9999.

351

Font data length must be 68 to 16384.

352

Insufficient font memory is available for the downloaded font.

380

Job request is outside the range 0 to 4.

400

The character immediately following { is invalid.

402

Field separator is not in the expected location.

403

Field separator was not found.

Errors 9-9

Page 128

404

The number or string that is currently being processed is too long.

405

Too many fields exist in the format. You cannot have more than 1000 fields in the format. Lines, boxes, and constant text fields count as fields.

409

The printer memory is full. Delete unnecessary formats or graphics from memory. If you are using a graphic file that is very large, consider using another mapping method (such as run length encoding) to reduce the required memory.

Communication Failures Errors 410 to 413 are usually caused by a hardware failure, by an incorrect SETUP option or by the host ignoring flow control (XON/OFF, CTS/RTS or DTR). Communication settings: Baud rate Word length Stop bits Parity Flow control

9-10 Errors

1200, 2400, 4800, 9600, 19200, 38400 7 or 8 1 or 2 Odd, Even, None None, XON/XOFF, DTR, CTS

410

Parity on the printer does not match the parity on the host. Check the parity setting under SETUP options.

411

Framing error. The printer cannot communicate with the host. Make sure the host is turned on, communication cables are connected correctly, port settings are correct, and communications are active. Check the baud rate, word length, and stop bits to make sure they match those at the host. Do not toggle between Microsoft® Windows® and MS-DOS, while using the COPY command, or you will receive a framing error. Exit Windows before using the COPY command. Re-transmit the data.

Page 129

412

There is a problem with flow control between the printer and the host. Make sure the printer and the host flow control settings match (both are DTR or both are XON/XOFF). If the error persists, call Technical Support.

413

Online receive queue is full. Check your printer’s XON/XOFF or DTR SETUP values to be sure there isn’t a flow control problem.

414

The internal keyboard buffer is full or you need a new keypad. Call Technical Support.

415

The buffer size you defined exceeds the total available in your machine.

416

Flash/PC board error. Call Technical Support.

417

Flash memory is full. Clear flash through the 9403 printer’s menu. Resend the format, graphic, and check digit packets. If the error reappears, call Technical Support.

427

Format name is invalid. Valid name is 1 - 8 characters inside quotes or "" for a printer-assigned name. Press the FEED button and try to continue. If the error reappears, call Technical Support.

428

Batch name is invalid or graphic not found. Press the FEED button and try to continue. If the error reappears, call Technical Support.

429

A field number appears more than once in a format.

430

The format uses a graphic file that cannot be found.

433

The batch references a field number that does not exist in the format.

497

An error occurred during the loop back test on the parallel port. Call Service.

Errors 9-11

Page 130

499

An error occurred during the loop back test on the serial port. Call Service.

Data Formatting Failures Formatting errors indicate that a field will print incorrectly. After you have checked the data stream and corrected the data, retransmit the format and batch. For errors 571-619, the batch will still print, but the field, font, bar code, or density may be incomplete, missing or contain incorrect data.

9-12 Errors

571

UPC or EAN bar code data length is invalid. The bar code data length in the batch does not fit the format.

572

A copy field, padded field, or incrementing field length is invalid. The field length in the batch does not fit the format or the field contains blanks. Or, the fixed length field does not contain the specified number of characters.

573

Price field length is invalid. The price field length in the batch does not fit the format or the field contains blanks.

574

No CD scheme or room for CD. The CD scheme in the batch does not fit the format or the field contains blanks.

575

The graphic included in your format could not be found.

611

Font, bar code or density is invalid. The font, bar code or density in the batch does not fit the format.

612

The data in this line of the batch is either missing or does not match the format.

613

Reference point off tag.