The text of a manual · part 11 of 19
Monarch 9412, 9413, 9414 Printers, pages 101 to 110
Pages 101 to 110 of 184
The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Monarch 9414 and Paxar 9414
Page 101
The following graphics can be used as a quick reference for the Status of Byte #2 and Byte #3. Byte #1 is the non-printable user-defined ENQ character.
Status Polling 7-3
Page 102
E N Q R e f e r e n c e Ta b l e - B y t e # 2 Char
Const. OFF
Const. ON
Comp. Failure
Corr. Error
Online Data Error
Busy
Active
Online
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
@
0
1
0
0
0
0
0
0
A
0
1
0
0
0
0
0
1
B
0
1
0
0
0
0
1
0
C
0
1
0
0
0
0
1
1
D
0
1
0
0
0
1
0
0
E
0
1
0
0
0
1
0
1
F
0
1
0
0
0
1
1
0
G
0
1
0
0
0
1
1
1
H
0
1
0
0
1
0
0
0
I
0
1
0
0
1
0
0
1
J
0
1
0
0
1
0
1
0
K
0
1
0
0
1
0
1
1
L
0
1
0
0
1
1
0
0
M
0
1
0
0
1
1
0
1
N
0
1
0
0
1
1
1
0
O
0
1
0
0
1
1
1
1
P
0
1
0
1
0
0
0
0
Q
0
1
0
1
0
0
0
1
R
0
1
0
1
0
0
1
0
S
0
1
0
1
0
0
1
1
T
0
1
0
1
0
1
0
0
U
0
1
0
1
0
1
0
1
V
0
1
0
1
0
1
1
0
W
0
1
0
1
0
1
1
1
1
0
1
0
1
1
0
0
0
Y
0
1
0
1
1
0
0
1
Z
0
1
0
1
1
0
1
0
[
0
1
0
1
1
0
1
1
\
0
1
0
1
1
1
0
0
]
0
1
0
1
1
1
0
1
^
0
1
0
1
1
1
1
0
_
0
1
0
1
1
1
1
1
‘
0
1
1
0
0
0
0
0
A "1" indicates the bit is turned on. A "0" indicates the bit is off.
7-4 Status Polling
Page 103
E N Q R e f e r e n c e Ta b l e - B y t e # 2 ( c o n t i n u e d ) Char
Const. OFF
Const. ON
Comp. Failure
Corr. Error
Online Data Error
Busy
Active
Online
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0 a
0
1
1
0
0
0
0
1 b
0
1
0
1
0
0
0
1 c
0
1
1
1
0
0
0
1 d
0
1
0
0
1
0
0
1 e
0
1
1
0
1
0
0
1 f
0
1
0
1
1
0
0
1 g
0
1
1
1
1
0
0
1 h
0
1
0
0
0
1
0
1 i
0
1
1
0
0
1
0
1 j
0
1
0
1
0
1
0
1 k
0
1
1
1
0
1
0
1 l
0
1
0
0
1
1
0
1 m
0
1
1
0
0
1
0
1 n
0
1
0
1
1
1
0
1 o
0
1
1
1
1
1
0
1 p
0
1
0
0
0
0
1
1 q
0
1
1
0
0
0
1
1 r
0
1
0
1
0
0
1
1 s
0
1
1
1
0
0
1
1 t
0
1
0
0
1
0
1
1 u
0
1
1
0
1
0
1
1 v
0
1
0
1
1
0
1
1 w
0
1
1
1
1
0
1
1
1
0
1
0
0
0
1
1
1 y
0
1
1
0
0
1
1
1 z
0
1
0
1
0
1
1
1
{
0
1
1
1
0
1
1
1
|
0
1
0
0
1
1
1
1
}
0
1
1
0
1
1
1
1
~
0
1
0
1
1
1
1
1
Dec 127
0
1
1
1
1
1
1
1
A "1" indicates the bit is turned on. A "0" indicates the bit is off.
Status Polling 7-5
Page 104
E N Q R e f e r e n c e Ta b l e - B y t e # 3 Char
Const. OFF
Const. ON
Low Battery
Format Error
Waiting Ribbon to Fault Dispense Label
Stock Fault
Online Error
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
@
0
1
0
0
0
0
0
0
A
0
1
0
0
0
0
0
1
B
0
1
0
0
0
0
1
0
C
0
1
0
0
0
0
1
1
D
0
1
0
0
0
1
0
0
E
0
1
0
0
0
1
0
1
F
0
1
0
0
0
1
1
0
G
0
1
0
0
0
1
1
1
H
0
1
0
0
1
0
0
0
I
0
1
0
0
1
0
0
1
J
0
1
0
0
1
0
1
0
K
0
1
0
0
1
0
1
1
L
0
1
0
0
1
1
0
0
M
0
1
0
1
1
0
0
1
N
0
1
0
0
1
1
1
0
O
0
1
0
0
1
1
1
1
P
0
1
0
1
0
0
0
0
Q
0
1
0
1
0
0
0
1
R
0
1
0
1
0
0
1
0
S
0
1
0
1
0
0
1
1
T
0
1
0
1
0
1
0
0
U
0
1
0
1
0
1
0
1
V
0
1
0
1
0
1
1
0
W
0
1
0
1
0
1
1
1
X
0
1
0
1
1
0
0
0
Y
0
1
0
1
1
0
0
1
Z
0
1
0
1
1
0
1
0
[
0
1
0
1
1
0
1
1
\
0
1
0
1
1
1
0
0
]
0
1
0
1
1
1
0
1
^
0
1
0
1
1
1
1
0
_
0
1
0
1
1
1
1
1
‘
0
1
1
0
0
0
0
0
A "1" indicates the bit is turned on. A "0" indicates the bit is off. 7-6 Status Polling
Page 105
E N Q R e f e r e n c e Ta b l e - B y t e # 3 ( c o n t i n u e d ) Char
Const. OFF
Const. ON
Low Battery
Format Error
Waiting Ribbon to Fault Dispense Label
Stock Fault
Online Error
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0 a
0
1
1
0
0
0
0
1 b
0
1
1
0
0
0
1
0 c
0
1
1
0
0
0
1
1 d
0
1
1
0
0
1
0
0 e
0
1
1
0
0
1
0
1 f
0
1
1
0
0
1
1
0 g
0
1
1
0
0
1
1
1 h
0
1
1
0
1
0
0
0 i
0
1
1
0
1
0
0
1 j
0
1
1
0
1
0
1
0 k
0
1
1
0
1
0
1
1 l
0
1
0
1
0
1
1
0 m
0
1
1
1
1
0
0
1 n
0
1
1
0
1
1
1
0 o
0
1
1
0
1
1
1
1 p
0
1
1
1
0
0
0
0 q
0
1
1
1
0
0
0
1 r
0
1
1
1
0
0
1
0 s
0
1
1
1
0
0
1
1 t
0
1
1
1
0
1
0
0 u
0
1
1
1
0
1
0
1 v
0
1
1
1
0
1
1
0 w
0
1
1
1
0
1
1
1
1
0
1
1
1
1
0
0
0 y
0
1
1
1
1
0
0
1 z
0
1
1
1
1
0
1
0
{
0
1
1
1
1
0
1
1
|
0
1
1
1
1
1
0
0
}
0
1
1
1
1
1
0
1
~
0
1
1
1
1
1
1
0
Dec 127
0
1
1
1
1
1
1
1
A "1" indicates the bit is turned on. A "0" indicates the bit is off.
Status Polling 7-7
Page 106
Job Request A Job Request returns status information about the most recently processed print job. You can send a job request after an ENQ or batch. You can send two levels of Job Requests: u
Numeric Error Codes Only (0, 1, or 2)
u
Verbose (3 or 4)
Syntax Field Type
{J,#} Valid Options
Description
Identifier
J
Job Status Request request#
0 1 2 3 4
Returns ASCII coded strings or numeric error codes
Example
Returns error number Returns number of labels printed in batch
{J,3}
The job response may not be immediate. If the printer has an error (out of supplies, ribbon problem, etc.), is in pause mode, or has insufficient memory, correct the problem and then resend the job request. If the problem is not corrected, no response is returned. If a formatting error has occurred, the job request will return the status. The printer must first interpret the format and batch data before returning the response. To clear an error, press the FEED button. An ENQ can also clear errors numbered less than 500. Once the error is corrected, a job request can be sent. The printer cannot accept another job request until the error is resolved.
7-8 Status Polling
Page 107
Page 108
The following syntax is the response for a Job 3 request. Syntax
{J,"Status1 A,B","Status2 A,B,C,D,E","FMT-1","BCH-2"}
"Status1 A,B"
Status1 A contains the field number, in the format or batch, where an error was found. If the error is not in the format or batch, a "0" is returned. Status1 B contains an error number, which represents the actual printer error. The error numbers can be found in Chapter 9, "Errors."
Example
{J,"2,612",}
2 is the field number where an error was found. 612 is the error number, indicating that data is missing or does not match the format definition for that field. Error numbers found in Status1 B, always have a value equal to or greater than 500. These are considered very serious errors. "Status2 A,B,C,D,E" contains the packet type, field type, field number, parameter, and error number. Status2 A- Packet Type represents the MPCLII packet that the error occurred on. The packet could be Format (F), Batch (B), Check Digit (A), or Font (W).
Status2 B- Field Type represents the MPCLII field that the error occurred on. If the packet has no fields, Status2 A will be replicated. If the error occurs before the field is identified a question mark is sent. Since the batch data is variable, a D is sent to indicate data.
7-10 Status Polling
Page 109
Status2 C- Field Number represents the field number within each packet. The packet header is the first field and each subsequent field is indicated by the field separator.
Status2 D- Parameter represents the parameter within the field that the error occurred. The numbering begins after the field identifier.
Status2 E- Error Number is the error that coincides with the error numbers presented in Chapter 9, "Errors."
"FMT-1/BCH-2"
The format or batch number is returned.
If more than one error occurred then only the most serious error will be acknowledged. {J,"","F,B,4,6,33","FMT-1","BCH-2"} Indicates that an error occurred on a bar code (B) field within a format (F) packet. The bar code field is the fourth (4) field in the packet. The error occurred in the sixth (6) parameter of the field. Error number 33 means the bar code density is invalid. To clear an error, press the FEED button. An ENQ can also clear errors numbered less than 500. Once the error is corrected, a job request can be sent. The printer cannot accept another job request until the error is resolved.
Status Polling 7-11
Page 110
The following syntax is the response for a Job 4 request. Syntax
{J,printed,total,"FMT-1","BCH-2"} printed the number of tags or labels already printed in the batch.
total the total number of tags or labels to be printed in the current batch.
"FMT-1/BCH-2"
The format or batch number is returned.
Example
{J,8,25,"FMT-3","Bch-2"}
8 out of 25 tags or labels have been printed from format number 3. Use a Job Request 4 when printing in the on-demand mode with a large number of tags or labels from a single batch. A Job Request 4 may not be accurate if tags or labels are printed in continuous mode, because of the response time involved. A Job Request 4 is not useful in single ticket batches (printing 1 of 1) or multiple single ticket batches. A batch has to be printing when you send the job request. You cannot use this job request on batches printing formats with incrementing fields.
7-12 Status Polling