Page 21

3. Setting Supply Options

The default setting for Print Position is 0. To change the setting, follow the steps listed under "Finding the Supply Options." Then follow the steps below. 1.

Press rR until you see <

2.

Press

SUPPLY Print Pos

>

E . You will see the previous setting, for example Enter print pos [+/-999]: +0

R

L

3.

Use the arrow keys to change the print position. Pressing increases the value (moves the image up); decreases it (moves the image down).

4.

Press will see

E when the number you want is displayed. You <

SUPPLY Print Pos

>

Press

NOTE: After changing settings in the Setup Menu, always return to the Main Menu before turning your printer off. The printer will not save changes to these menus if you turn it off before returning to the Main Menu.

3-7

Setting Supply Options

Q to exit to the Setup menu. 6. Press Q to exit to the Main Menu. 5.

Page 22

9406 Operator’s Handbook

Supply Position This function adjusts how much supply feeds out of the exit chute. You may need to adjust the supply in or out to allow:

• Labels to be torn off • Die cut labels to be removed easily, or to prevent them from falling off.

The range is -99 to +99, and the default is 0. The larger the number is, the more supply feeds out of the chute. The adjustments are in dots (0.0052 inch). NOTE: If you change this value in the middle of a batch, the change is immediate. It does not wait for the next batch to make the change. The default setting for Supply Position is 0. To change the setting, follow the steps listed under "Finding the Supply Options." Then follow the steps below. 1.

Press

R until you see r <

2.

Press

SUPPLY Supply Pos

>

E . You will see the previous setting, for example Enter supply pos [+/-99]: +0

R

3.

Use the arrow keys to change the supply position. Pressing increases the value (feeds more supply); decreases it (feeds less supply).

4.

Press will see

E when the number you want is displayed. You <

3-8

L

SUPPLY Supply Pos

>

Page 23

3. Setting Supply Options

Q to exit to the Setup menu. 6. Press Q to exit to the Main Menu. 5.

Press

NOTE: After changing settings in the Setup Menu, always return to the Main Menu before turning your printer off. The printer will not save changes to these menus if you turn it off before returning to the Main Menu.

Margin Position This function adjusts where the format prints horizontally on the supply. The adjustments are in dots (0.0052 inch), which is the smallest measurement the printer recognizes. The range is -99 to +99 (0.52 inches), and the default is 0. NOTE: If you change the Margin position in the middle of the batch, the change does not occur until the next batch, except for variable data, such as incrementing or decrementing fields. The changes occur immediately in variable data fields.

Print too far to the right.

Use the following rules of thumb as you set this position:

• If the data is too close to the left side of the supply, increase the number.

• If the data is too close to the right side of the supply, decrease the number.

3-9

Setting Supply Options

Print too far to the left.

Page 24

9406 Operator’s Handbook

The width of the print area is always four inches. When you move the image to the right or left on the supply, avoid moving the image outside the four inch print area. As you move the format to the right, the fields that would move past the four inch location of the supply "wrap around" and appear on the left side. Other fields move the full length you specify. If your supply is less than 4 inches, fields might move off the supply and not print. As you move the format to the left, fields that would move off the format stop at the 0.0" location of the supply. Other fields move the full length you specify. Making this change can alter the relative position of the fields. The default setting for Margin Position is 0. To change the setting, follow the steps listed under "Finding the Supply Options." Then follow the steps below. 1.

Press

R until you see <

2.

Press

SUPPLY Margin Pos

E . You will see the previous setting, for example, Enter margin pos [+/-99]: +0

R

3.

Use the arrow keys to change the print position. Pressing increases the value (moves the image toward the right side of the supply); decreases it (moves the image toward the left side of the supply). Press the arrow key once to change by one number at a time.

4.

Press will see

L

E when the number you want is displayed. You <

3-10

SUPPLY Margin Pos

Page 25

3. Setting Supply Options

Q to exit to the Setup menu. 6. Press Q to exit to the Main Menu. 5.

Press

NOTE: After changing settings in the Setup Menu, always return to the Main Menu before turning your printer off. The printer will not save changes to these menus if you turn it off before returning to the Main Menu.

Setting Supply Options

3-11

Page 26

9406 Operator’s Handbook

3-12

Page 27

4. Setting Communication Values You need to set the printer communication values to match your host’s online communications. Before entering the communication values, see your System Administrator. MAIN MENU

PRINT MODE

SUPPLY

SETUP

CONTRAST

DIAG.

DEFAULTS

PORT SETTINGS

The communication values are shown below. The default values are in bold. Baud rate Word length Stop bits Parity Flow control

1200, 2400, 4800, 9600 7 or 8 1 or 2 Odd, Even, None None, Xon/Xoff, DTR

Finding Communication Value Options Follow these steps to set communication values. 1.

From the Main Menu, press

MAIN MENU Setup

>

4-1

Setting Communication Values

<

R or L until you see

Page 28

9406 Operator’s Handbook

2.

Press

E . You will see SETUP Supply

3.

Press

R until you see <

4.

Press

>

SETUP Port Settings

E . You will see the first communications option. PORT SETTINGS Baud Rate

>

To change one of these options, follow the instructions under the correct heading. To exit an option without changing the setting, press .

Q

Baud Rate The default setting for Baud Rate is 9600. To change the setting, follow the steps listed under "Finding Communication Value Options." Then follow the steps below. 1.

E

Press to set the baud rate. You will see the previous setting, for example

<

BAUD RATE 2400

The options for baud rate are 1200 2400 4800 9600

4-2

>

Page 29

Setting the Communication Values

2.

Press press

R or L to display the baud rate you need, then E . You will see PORT SETTINGS Baud rate

>

Q to exit to the Setup menu. 4. Press Q to exit to the Main Menu. 3.

Press

NOTE: After changing settings in the Setup Menu, always return to the Main Menu before turning your printer off. The printer will not save changes to these menus if you turn it off before returning to the Main Menu.

Word Length The default setting for Word Length is 8. To change the setting, follow the steps listed under "Finding Communication Value Options." Then follow the steps below. 1.

Press

R until you see <

2.

Press

PORT SETTINGS Word Length

>

E . You will see the previous setting, for example, <

WORD LENGTH 8

The options for Word Length are

4-3

Setting Communication Values

7 8

Page 30

9406 Operator’s Handbook

3.

Press press

L or rR to display the word length you need, then E . You will see <

PORT SETTINGS Word Length

>

Q to exit to the Setup menu. 5. Press Q to exit to the Main Menu. 4.

Press

NOTE: After changing settings in the Setup Menu, always return to the Main Menu before turning your printer off. The printer will not save changes to these menus if you turn it off before returning to the Main Menu.

Stop Bits The default setting for Stop Bits is 1. To change the setting, follow the steps listed under "Finding Communication Value Options." Then follow the steps below. 1.

Press

R until you see <

2.

Press

PORT SETTINGS Stopbits

E . You will see the previous setting, for example, STOPBITS 1

The options for Stop Bits are 1 2

4-4

>

>