Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 3

Monarch 9406 Thermal Printer Messages Manual, pages 19 to 26

Pages 19 to 26 of 26

The original document is the PDF (85 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Monarch 9406 and Paxar 9406

Page 19

3. Operation Messages

Too Many Packets Format Not Saved

You tried to download or copy one more format than the printer can store. Refer to your System Administrator’s Guide for information about deleting formats.

Too Many Packets Graph Not Saved

You tried to download one more graphic than the printer can store. Refer to your System Administrator’s Guide for information about deleting graphics. The printer could save only part of the format. Remove any unneeded formats from printer memory and try to save the format again.

Writing to ROM! Format Not Saved

The data stream you tried to download specifies communication to the wrong device type. Refer to the System Administrator’s Guide for a list of valid devices. Correct the error, then re-transmit the data.

Writing to ROM! Graph Not Saved

The graphic data stream you tried to download specifies communication to the wrong device type. Refer to the System Administrator’s Guide for a list of valid devices. Correct the error, then re-transmit the data.

3-13

Operation Messages

Verify Failed!

Page 20

9406 Messages Manual

3-14

Page 21

Appendix A MPCL Error Codes This appendix lists MPCL error codes. The following table lists the codes in numerical order, followed by an explanation of the code’s meaning.

Explanation

01

The format ID is out of range. Use a number from 1 to 99.

04

The format length has exceeded the maximum feed length (9 inches).

05

The format width has exceeded the physical limit (4.23 inches).

10

The field number is out of range. Use a number from 1 to 30.

11

The number of characters in the field is out of range. Use a number from 1 to 30.

12

The field’s row position is out of bounds. The image length is 8 inches.

13

The field’s column position is out of bounds. The maximum image width is 4 inches.

15

Invalid character rotation. Enter 0 (for 0-degree rotation), 1 (for 90-degree rotation), 2 (for 180-degree rotation), or 3 (for 270-degree rotation).

16

Invalid field rotation. Enter 0 (for 0-degree rotation), 1 (for 90-degree rotation), 2 (for 180-degree rotation), or 3 (for 270-degree rotation).

17

The field number is out of sequence. All numbered fields must be in sequential order.

20

Invalid vertical magnification. Use a number from 1 to 7.

A-1

MPCL Error Codes

Code

Page 22

9406 Messages Manual

21

Invalid horizontal magnification. Use a number from 1 to 7.

30

The bar code height is greater than the image length. The height limit is 8 inches.

31

The human-readable portion of the bar code is invalid. See the System Administrator’s Guide for a list of values.

32

Invalid bar code type. See the System Administrator’s Guide for a list of values.

33

The bar code density is greater than the maximum allowed. See the System Administrator’s Guide for a list of values.

40

The line thickness is too large. Valid thicknesses are 1 through 99 dots.

41

The vector angle is greater than 359 degrees. Use an angle from 0 to 359 degrees.

42

The end row falls outside the image length. The maxmimum image length is 8 inches.

43

The end column falls outside the image width. The maximum image width is 4 inches.

50

The graphic ID is out of range. Use an ID from 1 to 99.

51

Invalid imaging mode. You must use zero.

101

The number of prints is outside the valid range. Use a number from 1 to 9999.

104

The batch ID is out of range. Use a number from 1 to 99.

106

The batch field number is greater than 30. Enter a smaller number.

200

Invalid rule number. Use 1, 4, 5, 30, 31, 42, or 60.

300

The printer does not support database packets. It supports only check digit and graphics packets.

A-2

Page 23

Appendix A

The check digit selector is out of range. Use a number from 1 to 9.

312

The check digit modulus is out of range. Use a number from 2 to 11.

313

The check digit length is greater than 30. Use a smaller number.

321

The graphic ID is out of range. Use a number from 1 to 99.

322

Invalid graphic imaging mode. You must use zero.

323

The graphic’s row position is out of bounds. Use a number no more than 8 inches.

324

The graphic’s column position is out of bounds. Use a number no more than 4 inches.

326

The line thickness in the graphic is greater than 99. Enter a smaller number.

327

Invalid graphics direction. For next and duplicate bit maps, use 0 or 1. For line vectors, use a number from 0 to 359.

328

The end position of a line segment is out of bounds. It must be within the imagable area.

329

Invalid adjustment count. Use a number from 0 to 250 for next and duplicate bit maps.

330

Invalid graphic duplicate count. Use a number no greater than 250.

500

Not enough memory to process the current format.

A-3

MPCL Error Codes

311

Page 24

9406 Messages Manual

A-4

Page 25

This page is a scan with no text; see it in the PDF.

Page 26

For supplies, service, or assistance call:

TOLL FREE: 1-800-543-6650 (In the U.S.A.) 1-800-263-4650 (In Canada)