A two-page Microscan configuration guide (P/N 83-216801 Rev C, 2015) for the QX Hawk C-Mount Industrial Imager. It lists the hardware for each setup, shows connector pin assignments and standalone, daisy chain and multidrop wiring layouts, and lists C-Mount lens accessories and how the configurable part numbers are built.
- Device
- QX Hawk C-Mount Industrial Imager, FIS-6801 part numbers p. 1
- Part number format
- FIS-6801-CLSG: C 0 = RS-422, 1 = Ethernet; L 0 = C-Mount, 2 = 30°, 3 = 45°, 4 = 12°, 5 = 15°; S 0 = SXGA CCD, 1 = WVGA CMOS; G = RoHS p. 2
- Connectors
- A: serial M12 12-pin plug on all models; B: M12 12-pin socket on serial models, M12 8-pin socket on Ethernet models p. 1
- Interface device
- QX-1 Interface Device 98-000103-02; trigger connector T, connectors 1, 2 and 3 bus power and data p. 1
- Serial host cordset
- QX Cordset, Host, Serial, M12 12-pin Plug to DB9 Socket, 1 m: 61-000152-02 p. 1
- Ethernet host cordset
- QX Cordset, Host, Ethernet, M12 8-pin Plug to RJ45, 1 m: 61-000160-01 or -02 p. 1
- Common cordset
- QX Cordset, Common, M12 12-pin Socket to M12 12-pin Plug, 1 m: 61-000162-02 p. 1
- MS-Connect 210 cordset
- QX Cordset, M12 12-pin Plug and Socket to MS-Connect 210, RS-232 or RS-422, 2 m: 61-000158-03 or -04 p. 1
- Power supply
- QX Power Supply, 100-240VAC, +24VDC, M12 12-pin Socket p. 1
- Photo sensor
- QX Photo Sensor, M12 4-pin Plug, NPN, Dark On, 2 m: 99-000020-02 p. 1
- Light cordset
- QX Cordset, Smart Series Light to QX-1, Continuous ON/OFF: 61-000207-01 p. 1
- C-Mount lenses
- 8mm, 12.5mm, 16mm, 25mm, 35mm, 50mm and 75mm lenses; UV and polarizing filters; extension tubes; standard (up to 48mm) and long (up to 72mm) lens protection housings p. 2
- Setups
- Standalone serial or Ethernet with QX-1, serial with MS-Connect 210, daisy chain, multidrop with MS-Connect 5100 p. 1, 2
What this manual walks you through
- Wiring a standalone imager by serial or Ethernet with the QX-1 p. 1
- Wiring imagers in a daisy chain p. 2
- Building a multidrop network with the MS-Connect 5100 p. 2
- Choosing C-Mount lenses and lens accessories p. 2
- Reading a QX Hawk C-Mount part number p. 2
Good to know
- Do not power more than four imagers from one power supply in a daisy chain; add a QX-1 and a supply for every four more. p. 2
- The 12.5mm lens is not for use with lens protection housings. p. 2
- Wire colors for each pin are given in the QX Hawk Industrial Imager User Manual, not this guide. p. 1
Questions this manual answers
How many QX Hawk imagers can share one power supply?
No more than four in a daisy chain; add a QX-1 and one power supply for every four more imagers. p. 2
What does the QX Hawk C-Mount part number mean?
In FIS-6801-CLSG, C is the interface (0 RS-422, 1 Ethernet), L the lens (0 C-Mount), S the sensor (0 SXGA CCD, 1 WVGA CMOS) and G marks RoHS. p. 2
Which cable connects a QX Hawk to a DB9 serial host?
QX Cordset, Host, Serial, M12 12-pin Plug to DB9 Socket, 1 m, part number 61-000152-02. p. 1
What lenses fit the QX Hawk C-Mount?
The guide lists C-Mount lenses of 8mm, 12.5mm, 16mm, 25mm, 35mm, 50mm and 75mm, with filters and extension tubes. p. 2
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
QX Hawk C-Mount Industrial Imager Configuration Guide Hardware Required Item Description Part Number 1 QX Hawk C-Mount Industrial Imager FIS-6801-XXXXG 2 QX-1 Interface Device 98-000103-02 3 QX Cordset, Common, M12 12-pin Socket to M12 12-pin Plug, 1 m 61-000162-02 4 QX Cordset, Host, Serial, M12 12-pin Plug to DB9 Socket, 1 m 61-000152-02 5 QX Cordset, Host, Serial, M12 12-pin Socket to DB9 Socket, 1 m 61-000153-02 97-000012-01 6 QX Power Supply, 100-240VAC, +24VDC, M12 12-pin Socket 7 QX Cordset, Host, Ethernet, M12 8-pin Plug to RJ45, 1 m (Ultra-Lock or Screw-On) 61-000160-01 or -02 8 QX Cordset, M12 12-pin Plug and Socket to MS-Connect 210, RS-232 or RS-422, 2 m 61-000158-03 or -04 9 QX Photo Sensor, M12 4-pin Plug, NPN, Dark On, 2 m 99-000020-02 10 QX Cordset, Smart Series Light to QX-1, Continuous ON/OFF (not shown) 61-000207-01 Note: Additional cordsets and accessories are available in the Microscan Product Pricing Catalog and the QX Hawk Industrial Imager User Manual.
Pin Assignments A is a serial M12 12-pin plug. It is the same for all models of the QX Hawk. B is a serial M12 12-pin socket for serial models and an Ethernet M12 8-pin socket for Ethernet models. Important: See the QX Hawk Industrial Imager User Manual for a list of the wire colors that correspond to each pin. RS-422/485 RxD (–)
Output 2Input CommonDefaultNew MasterPowerOutput 1Terminated
RX (–) RS-232 RxD/ RS-232 CTS
RS-422/485 RxD (+)RX (+)TriggerPowerRS-422/485 TxD (+)GroundTerminated TX (–)TerminatedInput 1RS-232 (Host) RxDInput CommonTerminatedTX (+)TriggerGroundRS-232 (Host) TxDOutput 3RS-232 TxD/ RS-232 RTSTerminatedRS-422/485 TxD (–)Output Common
A (All Models) M12 12-pin Plug
B (Ethernet) M12 8-pin Socket
B (Serial) M12 12-pin Socket
QX-1 Interface Device (Top View) Trigger
P+10-28VGround
Connector T on the QX-1 Interface Device is the trigger connector. Connectors 1, 2, and 3 can be used to bus power and data as required by the application.
T
Trigger/New Master / Input 1 Common
Trigger Connector (T) 4-pin Socket
Standalone Configuration Serial with QX-1
Ethernet with QX-111357 83 2 6
Serial with MS-Connect 210
2 969 1
Copyright ©2015 Microscan Systems, Inc.
P/N 83-216801 Rev C
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
QX Hawk C-Mount Configuration
Daisy Chain Configuration Serial with QX-1
Ethernet with QX-1 11511333331137229696
Important: Do not attempt to power more than four imagers with a single power supply in a daisy chain configuration. Add a QX-1 and one power supply for every four additional imagers in the daisy chain.
Multidrop Configuration Multidrop Network with MS-Connect 5100 1
1166 333 333222999
QX Hawk C-Mount Lens Accessories Kit, Adapter Plate, QX Hawk Lens Extension Tube, 5mm (C-CS Mount Adapter) Lens Extension Tube Set 0.5, 1, 5, 10, 20, 40mm Lens, 8mm F/1.4-16, Front Thread 25.5mm P 0.5mm, 2/3" C-Mount Lens, 12.5mm F/1.4-Close, Front Thread 40.5mm P 0.5mm, 1" C-Mount (Not for use with lens protection housings) Lens, 16mm F/1.4-16, Front Thread 27mm P 0.5mm, 2/3" C-Mount Lens, 25mm F/1.4-16, Front Thread 27mm P 0.5mm, 2/3" C-Mount Lens, 35mm F/2.1-22, Front Thread 25.5mm P 0.5mm, 2/3" C-Mount Lens, 50mm F/2.8-22, Front Thread 25.5mm P 0.5mm, 2/3" C-Mount Lens, 75mm F/3.9-32, Front Thread 25.5mm P 0.5mm, 2/3" C-Mount Lens, Skylight UV Filter, 25.5mm Lens, Polarizing Filter, 25.5mm, P 0.5 Lens, Polarizing Filter, 27mm, P 0.5 Lens Protection Housing, Standard Length (up to 48mm) Lens Protection Housing, Long (up to 72mm) Microscan Tools Drive
98-000143-01 98-92800471 98-CO206 98-92800571 98-000257-01 98-000258-01 98-000259-01 98-92800575 98-92800576 98-92800577 98-92800311 98-92800371 98-92800372 98-000218-01 98-000226-01 37-000010-01
Note: Additional accessories are available in the Microscan Product Pricing Catalog and the QX Hawk Industrial Imager User Manual.
QX Hawk C-Mount Configurable Part Numbers QX Hawk part numbers follow the format FIS-6801-CLSG: C (Comm) = 0 for RS-422, 1 for Ethernet; L (Lens) = 0 for C-Mount, 2 for 30°, 3 for 45°, 4 for 12°; 5 for 15°; S (Sensor) = 0 for SXGA CCD, 1 for WVGA CMOS; G = RoHS-Compliant.
Copyright ©2015 Microscan Systems, Inc.
www.microscan.com