Page 81

Scanner Parameters

Ethernet (cont.) 5. To change the host computer’s connection settings, click Properties on the General tab. To change TCP/IP settings: On the General tab, click the Properties button to bring up a list of items being used by the current connection. On the Local Area Connection Properties dialog, double-click Internet Protocol (TCP-IP).

6. The Internet Protocol (TCP/IP) Properties dialog will appear.

Select Use the following IP address to set the IP Address, Subnet, and Gateway.

QX-830 Compact Industrial Scanner User Manual

5-15

Page 82

Communication

Ethernet Status Enables or disables Ethernet connectivity in the scanner.

5-16

QX-830 Compact Industrial Scanner User Manual

Page 83

Scanner Parameters

IP Address Enter the IP address of the scanner in this field.

QX-830 Compact Industrial Scanner User Manual

5-17

Page 84

Communication

Subnet Enter the Subnet address of the scanner in this field.

5-18

QX-830 Compact Industrial Scanner User Manual

Page 85

Scanner Parameters

Gateway Enter the Gateway address of the scanner in this field.

QX-830 Compact Industrial Scanner User Manual

5-19

Page 86

Communication

IP Address Mode Determines how the scanner’s IP address will be defined.

Static In Static Mode, the scanner uses the user-defined IP address entered in ESP.

DHCP In DHCP Mode, the scanner automatically acquires the IP address, Subnet, and Gateway addresses from a DHCP or BOOTP server.

5-20

QX-830 Compact Industrial Scanner User Manual

Page 87

Scanner Parameters

TCP Port 1 One of two TCP ports for Ethernet communication with the scanner. The default setting is 2001.

Symbol Data Output Enables or disables decoded symbol data output from the scanner.

Extra Symbol Information Enables or disables extra symbol information output from the scanner.

Diagnostics Output Enables or disables diagnostics output from the scanner.

External Source Processing Mode Enables or disables processing of commands or data from sources external to the scanner. Command Command enables command processing in the scanner. Data Data enables Ethernet TCP Port 1 as a data source port. Note: The data path between in the source port and out the source port is always two-way. Data is copied from source data ports and all those source ports’ data is transmitted to the destination port, and from the destination port to the source port.

QX-830 Compact Industrial Scanner User Manual

5-21

Page 88

Communication

TCP Port 2 One of two TCP ports for Ethernet communication with the scanner. The default setting is 2003.

Symbol Data Output Enables or disables decoded symbol data output from the scanner.

Extra Symbol Information Enables or disables extra symbol information output from the scanner.

Diagnostics Output Enables or disables diagnostics output from the scanner.

External Source Processing Mode Enables or disables processing of commands or data from sources external to the scanner. Command Command enables command processing in the scanner. Data Data enables Ethernet TCP Port 2 as a data source port. Note: The data path between in the source port and out the source port is always two-way. Data is copied from source data ports and all those source ports’ data is transmitted to the destination port, and from the destination port to the source port.

5-22

QX-830 Compact Industrial Scanner User Manual

Page 89

Scanner Parameters

EtherNet/IP Enables or disables EtherNet/IP operation in the scanner.

Symbol Data Output Enables or disables decoded symbol data output from the scanner.

Extra Symbol Information Enables or disables extra symbol information output from the scanner.

Diagnostics Output Enables or disables diagnostics output from the scanner.

External Source Processing Mode Enables or disables processing of commands or data from sources external to the scanner. Command Command enables command processing in the scanner. Data Data enables EtherNet/IP as a data source port. Note: The data path between in the source port and out the source port is always two-way. Data is copied from source data ports and all those source ports’ data is transmitted to the destination port, and from the destination port to the source port. QX-830 Compact Industrial Scanner User Manual

5-23

Page 90

Communication

Protocol Selection In general, the point-to-point protocols will work well in most applications. They require no address and must use RS-232 or RS-422 communication standards. Protocols define the sequence and format in which information is transferred between the scanner and the host, or in the case of Multidrop, between the scanners and a concentrator. Note: In all protocol modes, the Preamble and Postamble character strings can be used to frame the decoded data, and both are included in calculating the LRC (Longitudinal Redundancy Check).

5-24

QX-830 Compact Industrial Scanner User Manual