For the Microscan QX-830

Page 41

3 Hardware Integration Contents Cordsets ....................................................................................................................................... 3-2 QX-830 and QX-1 Connectors and Pinouts.................................................................................. 3-3 Power and Trigger Switching........................................................................................................ 3-8 Port Routing.................................................................................................................................. 3-9 Application Examples ................................................................................................................. 3-10

This section introduces the details of QX-830 hardware, and explains how that hardware can be integrated in an application.

QX-830 Compact Industrial Scanner User Manual

3-1

Page 42

Cordsets

Cordsets The terms “cordset” and “cable” are both applicable to industrial connectivity, but they are not synonymous. Cordsets enable communications and power between scanners and interface devices. Cordsets have an M12 connector at one or both ends. Examples of cordsets are shown below.

M12 to M12 Cordset

M12 to RJ45 (Ethernet) Cordset

M12 to Photo Sensor Cordset

Cables do not have M12 connectors at either end. An example of a cable is shown below.

Cable with flying leads

3-2

QX-830 Compact Industrial Scanner User Manual

Page 43

Hardware Installation

QX-830 and QX-1 Connectors and Pinouts When deploying a network of scanners and interface devices in an industrial setting, it is important to use components whose pin assignments are arranged in a way that avoids communication errors and equipment damage. This can be achieved with components that are designed in a logical, consistent, and easy-to-implement way. The QX-830 has a very simple pin assignment methodology. The clearly identified connectors at the back of the unit can be used to receive and bus power, and also to send and receive data and commands. Connector A on the back of the QX-830 is a 12-pin plug on both Serial and Ethernet models.

Connector B is a 12-pin socket on RS-232 scanner models, and an 8-pin socket on Ethernet models.

QX-830 Connectors

QX-830 Connector Pin Assignments RS-422/485 RxD (–)

Output 2

Input Common

Default

New Master

RS-232 TxD/RS-232 RTS

Power

Output 1

Trigger

Ground RS-232 TxD

Output 3

RS-232 RxD/RS-232 CTS

RS-422/485 RxD (+)

Trigger

RS-232 RxD

Input Common

Input 1

Output Common

Function Trigger Power Default New Master Output 1 Output 3 Ground Input Common RS-232 (Host) RxD RS-232 (Host) TxD Output 2 Output Common

Terminated

RS-422/485 TxD (–)

Connector A (All Models) M12 12-pin Plug Pin 1 2 3 4 5 6 7 8 9 10 11 12

Power

RS-422/485 TxD (+)

Ground

Wire Color White Brown Green Yellow Gray Pink Blue Red Black Violet Gray/Pink Red/Blue

QX-830 Compact Industrial Scanner User Manual

Connector B (Serial Models) M12 12-pin Socket Pin 1 2 3 4 5 6 7 8 9 10 11 12

Function Trigger Power Default New Master Port 3 422/485 TxD (+) Port 3 422/485 RxD (+) Ground Input Common Port 2 TxD/Port 1 RTS Port 2 RxD/Port 1 CTS Port 3 422/485 TxD (–) Port 3 422/485 RxD (–)

Wire Color White Brown Green Yellow Gray Pink Blue Red Black Violet Gray/Pink Red/Blue

3-3

Page 44

QX-830 and QX-1 Connectors and Pinouts

QX-830 and QX-1 Connectors and Pinouts (continued) TX (+)

Terminated Terminated

RX (–)

Important: The 8-pin Ethernet version of Connector B does not have RS-422/485, Input 1, or RTS/CTS pins.

RX (+) Terminated TX (–) Terminated

Connector B (Ethernet Models) M12 8-pin Socket Pin 1 2 3 4 5 6 7 8

3-4

Function Terminated Terminated Terminated Port 4 TX (–) Port 4 RX (+) Port 4 TX (+) Terminated Port 4 RX (–)

QX-830 Compact Industrial Scanner User Manual

Page 45

Hardware Installation

Grounding the QX-830 Proper grounding is necessary for operator safety, noise reduction, and the protection of equipment from voltage transients. Buildings, including any steelwork, all circuits, and all junction boxes must be grounded directly to an earth ground in compliance with local and national electrical codes.

An earth ground is provided through the cable shields and chassis of the scanner.

Ground Loops Ground loops (signal degradation due to different ground potentials in communicating devices) can be eliminated or minimized by ensuring that both the host, scanner, and their power supplies are connected to a common earth ground.

QX-830 Compact Industrial Scanner User Manual

3-5

Page 46

QX-830 and QX-1 Connectors and Pinouts

Expected Power and Ground Connections for Proper Operation

Notes: • Ensure that mounting bracket “Earth” is at the same potential as power source “Earth”. • Supply “Return” and “Earth” ground must be stable, low-impedance reference points. • “2-Terminal Power Supply” must still provide an “Earth” connection to the scanner. • “Signal Ground” can be used for communications and/or discrete signal ground reference. It must not be used as Power Ground or Earth Ground.

3-6

QX-830 Compact Industrial Scanner User Manual

Page 47

Hardware Installation

QX-1 Interface Device The QX-1 Interface Device’s receptacles are physically the same as those on the QX-830, but they do not have explicit pin assignments. The QX-1 allows users to bus power and communications as required by the application. Connectors 1 and 3 are 12-pin plugs, and Connector 2 is a 12-pin socket. All three connectors can be assigned to bus power and data as required by the application. The two switches at the center of the device allow the user to route signals as needed. 1, 3 1,3, T

PWR TRIG

1,2, 3 1,2, 3, T

QX-1 Interface Device Pin 1 2 3 4

Assignment + 10-28V Trig/NM/Input 1 Common Ground Trigger

QX-1 Trigger Connector 4-pin Socket This simple diagram (shown on the base of the QX-1) illustrates how power, communications, I/O, and trigger signal can be routed through the QX-1 device depending on the needs of the application. The switches greatly increase signal routing flexibility.

QX-1 Communications - I/O Power - Trigger

QX-830 Compact Industrial Scanner User Manual

3-7

Page 48

Power and Trigger Switching

Power and Trigger Switching

1, 3 1,3, T

3-8

PWR TRIG

1,2, 3 1,2, 3, T

Power can be bussed between scanners and interface devices. At each location on a network where a new power supply is added, the Power switch on the QX-1 can be used to break power between Connector 2 and Connectors 1, 3, and T. The Trigger signal between Connector 2 and Connectors 1, 3, and T can be broken using the Trigger switch. This isolates trigger signals as required by the application.

QX-830 Compact Industrial Scanner User Manual

Page 49

Hardware Installation

Port Routing The physical advantages created by flexible signal routing and switching are enhanced further by Port Routing, which can be configured in ESP. Port Routing eliminates the need for dedicated “Host” and “Aux” ports in a traditional sense. With Port Routing, any port can be defined as a Host or Aux port. Port Routing also allows users to define the data types that are accessible from specific ports. The primary benefit of Port Routing is that any type of data can be routed to any port, and can be sent through multiple ports simultaneously. Multiple types of data can also be appended to the symbol data that is output from the scanner to the host. Command data, symbol data, extra symbol information, and diagnostic data are enabled by default in the QX-830. The table below lists different types of data, with examples for each data type. Data Type

Example

Command Data

Serial commands; scanner responses to serial commands.

Symbol Data

Any string of data encoded in a symbol.

Extra Symbol Information

Decodes per trigger, decode direction, configuration database index number.

Diagnostic Data

Laser status, temperature, service message.

The screen capture below (from ESP) shows the QX-830’s four communications ports and the parameters for each.

RS-232 A, RS-232 B, and RS-422 are serial. RS-232 A is always enabled. RS-232 B and RS-422 can be enabled or disabled to match the physical requirements of the application. Ethernet can also be enabled or disabled as required. RS-232 A, RS-232 B, and RS-422 can be configured for Baud Rate, Parity, Stop Bits, Data Bits, Symbol Data Output, Extra Symbol Information (Decodes Before Output, Symbol Position Output, etc.), Diagnostics Output, and External Source Processing Mode (Command or Data). Ethernet can be configured for IP Address, Subnet Mask, Gateway, IP Address Mode (Primary or Secondary TCP Port), Symbol Data Output, Extra Symbol Information, Diagnostics Output, and External Source Processing Mode.

QX-830 Compact Industrial Scanner User Manual

3-9

Page 50

Application Examples

Application Examples The following examples demonstrate how the components described in previous pages can be deployed in industrial applications.

Daisy Chain Daisy chain configurations are used in applications such as product packaging, where single items have multiple symbols. For example, a box with one symbol on the top and symbols on either side requires at least three scanners to ensure that all symbols will be decoded. The highlighted areas below demonstrate how a daisy chain can be arranged. One scanner is placed above the conveyor line and one scanner is placed on each side of the line. The three scanners essentially function as a single scanner, and data is sent from the primary scanner to the host or PLC. Important: Do not attempt to power more than four scanners with a single power supply in a daisy chain configuration. Add a QX-1 and one power supply for every four additional scanners in the daisy chain.

3-10

QX-830 Compact Industrial Scanner User Manual