Page 301
Appendices
PNP Source
PNP
Camera
= + T- 1 Trigger q D. CLC p98 ;
| New Master rs ony
| Input 1 | a
Input Common GND b
™ owe s ie)
cr io)
D+ = em, € - D-
CLC = Current Limiting Circuit
QX-830 Compact Industrial Scanner User Manual A-13
Page 302
Ground and Shield Considerations
Appendix C, Ground and Shield Considerations Proper grounding is necessary for operator safety, noise reduction, and the protection of equipment from voltage transients. Buildings, including any steelwork, all circuits, and all junction boxes must be grounded directly to an earth ground in compliance with local and national electrical codes.
An earth ground is provided through the cable shields and chassis of the scanner.
Ground Loops Ground loops (signal degradation due to different ground potentials in communicating devices) can be eliminated or minimized by ensuring that both the host, scanner, and their power supplies are connected to a common earth ground.
Grounding and Isolation Important: Mounting a QX-830 to grounded conductive material may cause communication problems or unreliable operation. If you need to mount the reader to a bracket or plate, be sure that a proper ground connection is available. If not, electrical isolation of the reader should be performed. Using Microscan’s Isolation Mounting Kit, P/N 98-9000038-01, will ensure that no ground loop or other external electrical noise can occur through the reader.
A-14
QX-830 Compact Industrial Scanner User Manual
Page 303
Appendices
Expected Power and Ground Connections for Proper Operation
Notes: • Ensure that mounting bracket “Earth” is at the same potential as power source “Earth”. • Supply “Return” and “Earth” ground must be stable, low-impedance reference points. • “2-Terminal Power Supply” must still provide an “Earth” connection to the scanner.
QX-830 Compact Industrial Scanner User Manual
A-15
Page 304
Flying Lead Cordset Pinouts
Appendix D, Flying Lead Cordset Pinouts Microscan offers two flying leads cordsets - 61-000166-02 and 61-000167-02 - for use in QX hardware configurations. The diagrams below show the correspondence of wire colors to pins.
61-000166-02, QX Cordset, M12 12-Pin Plug, Flying Leads The 61-000166-02 cordset connects to QX-830 Connector B (serial) and QX-1 Connector 2.
61-000167-02, QX Cordset, M12 12-Pin Socket, Flying Leads The 61-000167-02 cordset connects to QX-830 Connector A and QX-1 Connectors 1 and 3.
A-16
QX-830 Compact Industrial Scanner User Manual
Page 305
Appendices
Appendix E, Serial Commands Note: For a list of utility commands such as defaults, read rate requests, device control options, and scanner status requests, see Serial Utility Commands. Communication RS-232 A RS-232 B RS-422 Ethernet Ethernet TCP Ports EtherNet/IP RS-232 A Data Type RS-232 B Data Type RS-422 Data Type Ethernet TCP Port 1 Data Type Ethernet TCP Port 2 Data Type EtherNet/IP Data Type Preamble Postamble Response Timeout LRC Status ACK/NAK Options Polling Mode Options Autoconfiguration Daisy Chain Protocol Selection External Data Routing Array Communication Modes Read Cycle Trigger Mode / Trigger Filter Duration Serial Trigger Character External Trigger State End of Read Cycle Decodes Before Output Multisymbol Serial Trigger Start Character
<K100,baud rate,parity,stop bits,data bits> <K101,status,baud rate,parity,stop bits,data bits> <K102,status,baud rate,parity,stop bits,data bits> <K126,status,IP address,subnet,gateway,IP address mode> <K127,TCP Port 1,TCP Port 2> <K129,status> <K130,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K131,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K132,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K133,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K134,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K136,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K141,status,preamble> <K142,status,postamble> <K143,response timeout> <K145,status> <K147,RES,REQ,STX,ETX,ACK,NAK> <K148,RES,REQ,STX,ETX,ACK,NAK> <K150DAISY> <K160,protocol,address,protocol port> <K161,mode,destination port,ambles to source,echo to source,output at end of read cycle,output at ETX,output at timeout> <K162,mode,source,daisy chain i.d. status,daisy chain i.d.> <K200,trigger mode,leading edge trigger filter duration,trailing edge trigger filter duration> <K201,serial trigger character> <K202,external trigger state> <K220,mode,read cycle timeout> <K221,mode,number before output> <K222,number of symbols,multisymbol separator> <K229,start character>
QX-830 Compact Industrial Scanner User Manual
A-17
Page 306
Serial Commands Serial Trigger Stop Character Processing Timeout Motor On/Scan Speed Motor Off Maximum Element Automatic Gain Control
<K230,stop character> <K245,processing timeout> <K500,scan speed> <K501,motor off> <K502,maximum element> <K504,gain level,AGC sampling mode,AGC minimum,AGC maximum>
Symbol Detect Status / Transition Coun<K505,symbol detect status,transition counter> ter Scan Width Enhance <K511,status> AGC Tracking <K520,tracking> <K700,laser on/off,laser framing status,laser on position,laser off Laser Setup position,laser power> Configuration Database Number of Active Indexes <K252,number of active indexes,number of database cycles> <K253,index,gain,AGC mode,tracking,unused,unused,unused, Configuration Database framing status,laser on position,laser off position,laser power, background color> Switch Timing <K254,switch mode,time> Symbologies Quiet Zone <K450,quiet zone status> Background Color <K451,background color> Symbol Ratios <K452,Code 39,Codabar,Interleaved 2 of 5> Composite <K453,symbology status,separator status,separator> <K454,status,ID1,status1,ID2,status2,ID3,status3,ID4,status4, AIAG ID5a,ID5b,ID5c,status5, ID6,status6,ID7,status7,ID8, status8, ID9,status9,ID10,status10,ID11,status11,ID12,status12> Depth of Field Enhance <K456,DOF Enhance mode> <K470,status,check character status,check character output status, large intercharacter gap,fixed symbol length status,fixed symbol Code 39 length,full ASCII set> <K471,status,start/stop match status,start/stop output status, Codabar large intercharacter gap,fixed symbol length status,fixed symbol length,check character type,check character output status> <K472,status,check character status,check character output status, Interleaved 2 of 5 symbol length 1,symbol length 2,guard bar,range mode status> <K473,mode,EAN status,supplementals status,separator status, UPC/EAN separator character,supplementals type,UPC-E as UPC-A> <K474,status,fixed symbol length status,fixed symbol length, EAN status,output format,application record separator status, Code 128 / EAN 128 application record separator character,application record brackets, application record padding,separation factor> Code 93 <K475,mode,fixed symbol length status,symbol length> <K476,status,scan line limit,fixed symbol length status,fixed PDF417 symbol length,decode at end of read cycle> <K477,status,fixed bar count status,fixed bar count,minimum bar Pharmacode count,bar width mode,direction,fixed threshold value>
A-18
QX-830 Compact Industrial Scanner User Manual
Page 307
Appendices DataBar Omnidirectional (RSS-14) DataBar Limited (RSS Limited) DataBar Expanded (RSS Expanded) MicroPDF417 Symbol Reconstruction
<K482,status> <K483,status> <K484,status,fixed symbol length status,fixed symbol length> <K485,status,scan line limit,fixed symbol length status,fixed symbol length> <K496,symbol reconstruction redundancy,symbol reconstruction effort>
I/O Parameters Calibration Options Serial Verification Beeper Quality Output Symbol Data Output Read Duration Output No Read Message Bad Symbol Message No Symbol Message Input 1 Green Flash LED Status Indicators Symbol Position Output Database Identifier Output EZ Button EZ Button Modes Auto Framing Options Trend Analysis Output 1 Trend Analysis Output 2 Trend Analysis Output 3 Diagnostics Output 1 Diagnostics Output 2 Diagnostics Output 3 Output 1 Parameters Output 2 Parameters Output 3 Parameters
<K521,unused,video,scan speed,laser power,laser framing, symbology> <K701,serial command echo status, serial command beep status, control/hex output> <K702,status> <K704,quality output separator, decodes per trigger status, decode direction output> <K705,symbol data output status, when to output symbol data, symbology identifier status> <K706,status,separator> <K714,status,message> <K715,status,message> <K716,status,message> <K730,input mode,active state> <K750,green flash mode,unused,green flash duration> <K751,status,bar graph,I/O 1,I/O 2> <K758,scan status,separator> <K759,status,separator character> <K770,status,default on power-on> <K771,single beep,two beeps,three beeps,four beeps> <K773,laser framing> <K780,trend analysis mode,number of triggers,number to output on,decodes per trigger> <K781,trend analysis mode,number of triggers,number to output on,decodes per trigger> <K782,trend analysis mode,number of triggers,number to output on,decodes per trigger> <K790,high temperature,service unit,unused,laser current high, laser current low,low temperature> <K791,high temperature,service unit,unused,laser current high, laser current low,low temperature> <K792,high temperature,service unit,unused,laser current high, laser current low,low temperature> <K810,output on,output state,pulse width,output mode> <K811,output on,output state,pulse width,output mode> <K812,output on,output state,pulse width,output mode>
QX-830 Compact Industrial Scanner User Manual
A-19
Page 308
Serial Commands Matchcode Matchcode Master Symbol Database Size New Master Pin Sequence Step Master Symbol Match Replace Mismatch Replace Diagnostics High Temperature Threshold Low Temperature Threshold Counts (Read-only) Hours Since Reset (Read-only) Service Message Laser Current Warning Message User-Defined Name Output Format Format Extract Format Insert Format Assign Output Format Status Output Filter Configuration Output Filter Enable
A-20
<K223,matchcode type,sequential matching,match start position, match length,wild card,sequence on no read,sequence on mismatch> <K224,number of master symbols> <K225,status> <K228,sequence step> <K231,index,master symbol data> <K735,status,replacement string> <K736,status,replacement string> <K402,status,message> <K403,status,message> <K406> (returns: power-on,resets, power-on saves,custom default saves) <K407> (returns: hours,minutes) <K409,status,service message, threshold,resolution> <K411,laser high status,laser high message,laser low status, laser low message> <K412,user-defined name> <K740,output index,start location,length> <K741,output index,length,hex string> <K742,symbol number,status> <K743,output format status> <K744,filter number,symbology,length,wildcard,placeholder, data,decode direction,database index> <K745,number of filters>
QX-830 Compact Industrial Scanner User Manual
Page 309
Appendices
Serial Command Format Microscan readers are controlled by two types of serial commands: configuration commands and utility commands.
Rules that apply to both configuration and utility commands • Less than ‘<‘ and greater than ‘>’ angle bracket characters enclose the commands. • Commands and data are case sensitive. Characters must be entered as upper or lower case, as specified.
Serial Utility Commands Serial Utility Commands are sent during operations and are not followed by <A> or <Z>.
Serial Configuration Commands (K Commands) Microscan’s serial configuration commands begin with a single “K” character followed by a 3-digit numeric character, comma-separated command fields, and an initializing command, as follows: <Knumeric character,data,data,...etc.><initializing command> An initializing command <Z> or <A> may follow the command. • <Z> initializes the scanner’s memory and saves for power-on. • <A> initializes the scanner’s memory but does not save for power-on. For example, to enable UPC and save the change for power-on, send <K473,1><Z>. To change Baud Rate and reset without saving changes for power-on, send <K100,3><A>.
Serial Configuration Command Conventions • All command fields (except the last) must be followed by a comma (without a space). • NULL cannot be used. The characters <, >, and , can be used, but only if entered as hex pairs (see ASCII Character Entry Modifier). • All fields preceding a modified field must be included. • If there is no change in preceding fields, then commas alone can be entered in these fields. For example, if only the last field in the following command is changing, <K100,4,1,0,0> can be entered as <K100,,,,0>. • All fields following a modified field can be omitted. For example, to change Baud Rate only, send <K100,3>.
QX-830 Compact Industrial Scanner User Manual
A-21
Page 310
Serial Commands
Concatenating Configuration Commands Commands can be concatenated (added together) in a single string. For example, <K145,1><K220,1><K450,1><A> enables LRC, sets End of Read Cycle mode to New Trigger, enables Narrow Quiet Zone, and resets the data buffers without saving the changes for power-on.
Serial Command Status Request To ensure that any command was received and accepted, send the Show Reader Status command: <?>. The status of a specific serial command can be requested by entering the command followed by a question mark. For example, send <K142?> to request the status of Postamble.
Entering Control Characters in Serial Commands To enter control characters within a serial command, hold down the Ctrl key while typing the desired character. Example: To enter a carriage return and line feed (^M^J), enter <K141,1,CNTL-m CNTL-j>
A-22
QX-830 Compact Industrial Scanner User Manual