Page 21
Quick Start
Step 9, Save Changes in ESP To make changes to a configuration setting:
3. Place the cursor in the selection box, scroll down to the setting to be changed, and click once on the setting.
1. Left-click on the + to expand the desired tree. 2. Double-click on the desired parameter and click once in the selection box to view options.
4. Left-click again on the open screen to complete the selection.
5. Right-click on the open screen and select Save to Reader to implement the command in the scanner.
Saving Options • Send, No Save. Changes will be lost when power is re-applied to the scanner. • Send and Save. This activates all changes in current memory and saves to the scanner for power-on.
QX-830 Compact Industrial Scanner User Manual
1-11
Page 22
Save Changes in ESP
1-12
QX-830 Compact Industrial Scanner User Manual
Page 23
2 Using ESP Contents EZ Mode........................................................................................................................................2-2 App Mode......................................................................................................................................2-3 Menu Toolbar ................................................................................................................................2-4 Navigating in ESP .......................................................................................................................2-15 Send/Receive Options ................................................................................................................2-16
This section explains the basic structure and elements of ESP (Easy Setup Program). When ESP is opened, unless otherwise specified in ESP Preferences, the EZ Mode view will appear. App Mode contains several configuration menus (Communication, Read Cycle, Symbologies, I/O Parameters, Matchcode, and Diagnostics), a Setup interface, a Terminal interface, and a Utilities interface. ESP can be used to configure the QX-830 in three different ways: • Graphic User Interfaces: Scanner settings can be configured using such point-and-click tools as buttons, spin boxes, check boxes, and drag-and-drop functions. • Tree Controls: Each configuration menu contains a list of all option settings that pertain to that specific area of scanner operation. For example, the Read Cycle menu shows a Laser Setup command, and then a list of the parameters Laser On/Off, Laser Framing Status, Laser On Position, Laser Off Position, and Laser Power. Each parameter can be configured using dropdown menus or fields where characters can be entered. • Terminal: ESP’s Terminal allows the user to send serial configuration and utility commands directly to the scanner by typing them in the provided field. Information about using specific commands in ESP is provided in subsequent sections. For ESP system requirements, see ESP System Requirements in Chapter 1, Quick Start.
QX-830 Compact Industrial Scanner User Manual
2-1
Page 24
EZ Mode
EZ Mode EZ Mode allows the user to test read rate and calibrate the scanner. After connecting to the scanner, the EZ Mode view will appear. On-screen instructions assist the user with positioning, testing, and calibration.
Test Click the Test button to start the read rate test for a quick indication of the scanner’s read capabilities and the limits of the application. When Decodes per Second is unchecked, the test will count the percentage of decodes relative to the number of actual scans. Click Stop to end the test.
Calibrate The calibration routine that will optimize the scanner by comparing Read Rates at various camera and image processing settings.
Starts Read Rate test.
Click Calibrate to begin the calibration routine. Calibration is explained at the left of the EZ Mode screen, and also in Quick Start.
Click the App Mode button to access configuration trees and other setup features.
2-2
QX-830 Compact Industrial Scanner User Manual
Page 25
Using ESP
App Mode From EZ Mode, click on the App Mode button to access the tabbed tree controls in Parameters, the intuitive user interfaces in Setup, the Terminal interface, and the Utilities interface.
Note: The App Mode and EZ Mode buttons appear in the same position to allow easy switching between these primary modes. Calibration, Configuration Database, Ordered Output, Output Format Click this icon to return to EZ Mode.
Menu toolbar
Click here to open the Terminal view.
Read Rate, Counters, Device Control, Differences from Default, Master Database, Digital Bar Code, Firmware Autoconnect to the scanner, Send and Receive command settings, and Switch Model
QX-830 Compact Industrial Scanner User Manual
Tabbed tree controls
2-3
Page 26
Menu Toolbar
Menu Toolbar File New Whenever New is selected, the default configuration of ESP is loaded.
Open/Save When Save or Save As is selected, the ESP configuration is saved to the host computer’s hard drive and available whenever the same file is selected under Open. Important: When configuration changes are saved to the hard drive, these changes are not automatically saved to the scanner. The illustration below shows how settings can be saved and received between ESP and the scanner, and ESP and the host hard drive.
(Save to Scanner) (Receive Scanner Settings)
Import/Export Import converts the ASCII settings from a text file to ESP configuration settings. Export converts the active ESP configuration settings to an ASCII text file.
2-4
QX-830 Compact Industrial Scanner User Manual
Page 27
Using ESP
Model The Model dropdown menu shows a list of recent scanners that have been used with ESP. When a different model is chosen, the connection to the present model is terminated.
To connect to another model, select New Model, choose a new model from the pop-up menu that appears, and click OK. Note: When an ESP file is saved, the settings of all the models defined in that file are saved.
QX-830 Compact Industrial Scanner User Manual
2-5
Page 28
Menu Toolbar
Options The Options menu allows the user to save memos and set up ESP Preferences. Note: Preferences will be saved and loaded into ESP whenever ESP is opened next, whether or not the ESP file is saved.
Preferences > General Tab
The Toolbar Style options allow the user to determine how ESP will display the mode options in the two rows at the top of the screen.
Reload Last File At startup, reloads the last file saved to the host computer’s hard drive.
Show Model Prompt At startup, shows the model menu displaying all supported scanners.
Show Connect Prompt At startup, displays the Would you like to connect to the QX-830? prompt.
Receive After Connect At startup, loads the scanner’s settings into ESP. (This is not recommended if ESP settings are needed for future use.)
Skip EZ Mode At startup, skips EZ Mode and opens directly in App Mode.
Enable ‘Send and Save as Customer Defaults’ At startup, enables the Send and Save as Customer Defaults option in the Send/Recv command. 2-6
QX-830 Compact Industrial Scanner User Manual
Page 29
Using ESP
Preferences > Terminal Tab
Show Non-Printable Characters When Show Non-Printable Characters is enabled, characters such as “CRLF” will be displayed in the Terminal window. When Enhanced Format is checked, the characters are displayed with more detailed formatting.
Change Keyboard Macros Clicking the Change Keyboard Macros button brings up the Function Keys dialog. In this dialog, select the desired function key and then enter the macro keystrokes in the associated key map. For example, to make Ctrl-F2 the keystroke to send a trigger character, select F2, then in the Ctrl row, enter <trigger character> and click OK. Then whenever the Ctrl-F2 keystroke is pressed, the trigger character will start the read cycle. Note: The F1 key is reserved for opening ESP Help and the F3 key is reserved for the Find Next function.
Change Font Allows the user to modify the font used for decode data received from the scanner on the Terminal.
Change Echo Font Allows the user to modify the font used for command characters typed into the Terminal.
Enable Echo Allows the user to enter command characters in Terminal.
Display Incoming Data Even When Not in Focus When Display Incoming Data Even When Not in Focus is enabled, data from the scanner will continue to appear in the Terminal even when ESP is not the top window.
QX-830 Compact Industrial Scanner User Manual
2-7
Page 30
Menu Toolbar
Preferences > Bar Code Options Tab
Sizing Information Sets the bar height (in inches) and bar width (in mils, or thousandths of an inch) of user-created symbols. Example: A bar width of 13 mils is 0.013 inches.
Caption Allows the user to define a caption for the symbol, and to determine the alignment of the caption in relation to the symbol.
2-8