Page 101

Scanner Parameters

Full Duplex Mode When Full Duplex Mode is enabled, the following conditions apply: Symbol Data to Source = Fixed to Disabled Ambles to Source = Fixed to Disabled Echo to Source = Fixed to Disabled Output at End of Read Cycle = Fixed to Disabled Output at ETX = Fixed to Disabled with user-defined characters. Default character will be used if this setting is set to Disabled. Output at Timeout = Fixed to Disabled with user-defined timeout. Default time will be used if this setting is set to Disabled. Mode of Operation • Source Port data is not echoed back to itself. • Source Port data is ignored when the Destination Port is in Polling Mode. • Source Port data or symbol data is sent to the Destination Port whenever it is received. • Source Port data is always sent to the Destination Port without a Preamble or Postamble. • Symbol data is not sent to the Source Port. • Destination port data is echoed to the source port in an un-polled mode.

Custom Mode Custom allows for user-defined communication (Ambles to Source, Echo to Source, Output at End of Read Cycle, Output at ETX, Output at Timeout).

QX-830 Compact Industrial Scanner User Manual

5-35

Page 102

Communication

Destination Port Determines the port to which data will be sent.

Ambles to Source Enables or Disables the ability to send Preambles and Postambles to the Source port.

Echo to Source Enables or Disables the ability to send an Echo to the Source port.

Output at End of Read Cycle Enables or Disables the ability to output data at the end of read cycle.

5-36

QX-830 Compact Industrial Scanner User Manual

Page 103

Scanner Parameters

Output at ETX Determines the output at ETX.

Output at Timeout Determines the Timeout value for output.

QX-830 Compact Industrial Scanner User Manual

5-37

Page 104

Communication

Array Communication Modes

Mode Daisy Chain When set to Daisy Chain, follows Microscan Daisy Chain protocol. Note: Daisy Chain can also be autoconfigured by sending the Daisy Chain Autoconfigure serial command.

Source Defines the communication port.

Daisy Chain ID Status When enabled, the scanner will append a two-character prefix to each scanner in the array. This allows the user to identify which scanner sent the data. Note: Daisy Chain ID will automatically disable Symbol Data Output, Extra Symbol Information, and Diagnostics Output for the Source Port. Symbol Data Output will be automatically enabled, Extra Symbol Information will be automatically enabled, and Diagnostics Output will be automatically disabled for the Destination Port.

5-38

QX-830 Compact Industrial Scanner User Manual

Page 105

Scanner Parameters

Daisy Chain ID The Daisy Chain ID is a two-character identifier.

QX-830 Compact Industrial Scanner User Manual

5-39

Page 106

Communication

Daisy Chain Autoconfigure For quick setup of a daisy chain configuration. The command to Autoconfigure the daisy chain is sent to the primary scanner and the software responds in the following ways: • Counts the number of secondary scanners in the daisy chain. • Assigns an internal ID number (1...n) to each secondary scanner, where the first secondary scanner is number 1 (the primary scanner’s ID being a 0). • Propagates the communication settings and the relevant operating modes of the primary scanner to the ports of each secondary scanner. • Resets each secondary scanner. • Confirms that each secondary scanner has acquired the new settings. When setting up a daisy chain operation, perform the following steps: 1. Set the primary scanner (the one connected to the host) to Serial Data Trigger Mode. This sets all the scanners in the chain to Serial Data when the command is executed. Important: All secondary scanners must be set to Serial Data Trigger Mode for Daisy Chain to function. Before Autoconfigure, the primary scanner must be set to Serial (S): Host

S

Primary Scanner

S

Secondary Scanner

S

Secondary Scanner

2. Send the <K150DAISY> command from ESP’s Terminal. 3. If necessary, set the primary scanner to External Edge. After Autoconfigure, the primary scanner can be set to External Edge (E), but the other scanners must remain in Serial (S): Host

E

Primary Scanner

S

Secondary Scanner

S

Secondary Scanner

Important: If the scanner is Ethernet-enabled, first check to determine if RS-232 B is available. If it is available, set RS-232 B as the Source port in Array Communication Modes. Otherwise, set RS-232 A as the Source port. Port Routing for Symbol Data Output and Extra Symbol Information will be disabled on the Source port.

5-40

QX-830 Compact Industrial Scanner User Manual

Page 107

Scanner Parameters

Preamble Useful for identifying and controlling incoming data. For example, defining the preamble as a carriage return and a line feed causes each decoded message to be displayed on its own line.

Preamble Characters Allows the user to define up to four postamble characters that can be added to the end of the decoded data

QX-830 Compact Industrial Scanner User Manual

5-41

Page 108

Communication

Postamble Useful for identifying and controlling incoming data. For example, defining the postamble as a carriage return and a line feed causes each decoded message to be displayed on its own line.

Postamble Characters Allows the user to define up to four postamble characters that can be added to the end of the decoded data.

5-42

QX-830 Compact Industrial Scanner User Manual

Page 109

Scanner Parameters

Read Cycle Click the App Mode button and then the Parameters button to display the tree control tabs. Then click the Read Cycle tab to display the Read Cycle tree control.

The * indicates that the setting is the default.

To open nested options, single-click the +.

To change a setting, double-click the setting and use the cursor to scroll through the options.

Note: Read Cycle settings can also be sent to the scanner from ESP’s Terminal using Microscan’s K command format. Refer to the Read Cycle section of Appendix E.

QX-830 Compact Industrial Scanner User Manual

5-43

Page 110

Read Cycle

Read Cycle Setup Setting up read cycle and triggering parameters involves a series of decisions based on the particular application, as follows: 1. Select the number of symbols to be read in a single cycle. 2. Decide on the trigger type to be used: if serial, choose a serial character; if external, choose either External Level or External Edge. 3. Designate how the read cycle should end (Timeout, New Trigger).

5-44

QX-830 Compact Industrial Scanner User Manual