The text of a manual · part 1 of 43
QX-830 Compact Industrial Scanner User Manual, pages 1 to 10
Pages 1 to 10 of 422
The original document is the PDF (7.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan QX-830
Page 1
MICROSCAN.
Qx-830 Compact Industrial scanner User Manual
P/N 84-000830 Rev C
Page 2
Copyright and Disclaimer Copyright ©2015 Microscan Systems, Inc. Tel: +1.425.226.5700 / 800.762.1149 Fax: +1.425.226.8250 All rights reserved. The information contained herein is proprietary and is provided solely for the purpose of allowing customers to operate and/or service Microscan manufactured equipment and is not to be released, reproduced, or used for any other purpose without written permission of Microscan. Throughout this manual, trademarked names might be used. We state herein that we are using the names to the benefit of the trademark owner, with no intention of infringement.
Disclaimer The information and specifications described in this manual are subject to change without notice.
Latest Manual Version For the latest version of this manual, see the Download Center on our web site at: www.microscan.com.
Technical Support For technical support, e-mail: helpdesk@microscan.com.
Warranty For current warranty information, see: www.microscan.com/warranty.
Microscan Systems, Inc. United States Corporate Headquarters +1.425.226.5700 / 800.762.1149 United States Northeast Technology Center +1.603.598.8400 / 800.468.9503 European Headquarters +31.172.423360 Asia Pacific Headquarters +65.6846.1214 ii
QX-830 Compact Industrial Scanner User Manual
Page 3
Introduction
Table of Contents Chapter 1
Quick Start
Step 1 Check Hardware .......................................................................... 1-2 Step 2 Connect the System ..................................................................... 1-3 Step 3 Position Scanner and Symbol ...................................................... 1-4 Step 4 Install ESP.................................................................................... 1-5 Step 5 Select Model ................................................................................ 1-6 Step 6 Connect ........................................................................................ 1-7 Step 7 Test Read Rate .......................................................................... 1-10 Step 8 Configure the Scanner ............................................................... 1-11 Step 9 Save Changes in ESP................................................................ 1-12
Chapter 2
Using ESP
EZ Mode .................................................................................................. 2-2 App Mode ................................................................................................ 2-3 Menu Toolbar .......................................................................................... 2-4 Navigating in ESP................................................................................. 2-15 Send/Receive Options .......................................................................... 2-16
Chapter 3
Hardware Integration
Cordsets .................................................................................................. 3-2 QX-830 and QX-1.................................................................................... 3-3 Power and Trigger Switching................................................................... 3-8 Port Routing............................................................................................. 3-9 Application Examples ............................................................................ 3-10
Chapter 4
Scanner Setup
Calibration ............................................................................................... 4-2 Configuration Database ........................................................................... 4-4 Ordered Output........................................................................................ 4-6 Output Format ....................................................................................... 4-10
Chapter 5
Scanner Parameters
Communication........................................................................................ 5-2 Read Cycle ............................................................................................ 5-43 Symbologies .......................................................................................... 5-70 I/O Parameters .................................................................................... 5-107 Matchcode ........................................................................................... 5-168 Diagnostics .......................................................................................... 5-177
Chapter 6
Terminal
Terminal Window ..................................................................................... 6-2 Find.......................................................................................................... 6-3 Send ........................................................................................................ 6-4 Macros..................................................................................................... 6-5 Terminal Window Menus ......................................................................... 6-6
QX-830 Compact Industrial Scanner User Manual iii
Page 4
Table of Contents Chapter 7
Utilities
Serial Utility Commands .......................................................................... 7-2 Read Rate ............................................................................................... 7-4 Counters .................................................................................................. 7-6 Device Control ......................................................................................... 7-8 Differences from Default.......................................................................... 7-9 Master Database ................................................................................... 7-10 Digital Bar Code .................................................................................... 7-16 Firmware ............................................................................................... 7-17 Default/Reset/Save ............................................................................... 7-20 Scanner Status Requests...................................................................... 7-22 Other Serial Utility Commands .............................................................. 7-23 Embedded Menus ................................................................................. 7-28
Appendices Appendix A General Specifications .........................................................A-2 Appendix B Electrical Specifications .......................................................A-6 Appendix C Ground and Shield Considerations ....................................A-14 Appendix D Flying Lead Cordset Pinouts..............................................A-16 Appendix E Serial Commands ..............................................................A-17 Appendix F Protocol Commands...........................................................A-80 Appendix G ASCII Table .......................................................................A-89 Appendix H Configuring Ethernet TCP/IP .............................................A-90 Appendix I Using EtherNet/IP................................................................A-93 Appendix J Operating EtherNet/IP Serial Gateway Data Fields..........A-102 Appendix K Allen-Bradley Version 16 PLC Setup ...............................A-104 Appendix L Allen-Bradley Version 20 PLC Setup ...............................A-118 Appendix M EIPScan Setup ................................................................A-125 Appendix N Interface Standards .........................................................A-131 Appendix O Glossary of Terms ...........................................................A-132 iv
QX-830 Compact Industrial Scanner User Manual
Page 5
Introduction
About the QX-830 Compact Industrial Scanner The key features of the QX-830 Compact Industrial Scanner are: • X-Mode™ symbol reconstruction and aggressive decode algorithm • Ethernet TCP/IP and EtherNet/IP™ • Ultra-high-performance processing • Real-time decoding • Green Flash performance indicator • LED array for performance, communication, and I/O user feedback • EZ Button for setup and testing • Compact size for easy integration into a wide variety of applications
Scanner Communication There are three ways to configure and test the QX-830: • Microscan’s Windows-based ESP Software (Easy Setup Program), which offers point-and-click ease of use and visual responses to user adjustments. • Serial commands, such as <K100,1>, that can be sent from ESP’s Terminal or another terminal program. • The EZ Button on the side of the scanner.
“EtherNet/IP” is a trademark of the Open DeviceNet Vendors Association.
QX-830 Compact Industrial Scanner User Manual v
Page 6
Warning and Caution Summary
Warning and Caution Summary This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communication. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna; • Increase the separation between the equipment and receiver; • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected; • Consult the dealer or an experienced radio/TV technician for help. For connection to a UL-listed direct plug-in power unit marked Class II and rated 10 to 28 VDC at 5 watts or greater. European models must use a similarly rated Class I or Class II power supply that is certified to comply with standard for safety EN 60950. CAUTION: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. There are no user-serviceable parts in the scanner. Opening the scanner voids the Microscan Systems, Inc. warranty and could expose the user to laser diode power of up to 7mW. The laser beam can be harmful to eyesight. Avoid eye contact with the laser beam. Never point the beam at other people, or in a direction where people may be passing. CAUTION: LASER RADIATION - DO NOT STARE INTO BEAM - CLASS 2 LASER PRODUCT; 655nm, 1.75mW, 40~186µS. DANGER: (Invisible) Laser Radiation when open (and interlock defeated). AVOID DIRECT EXPOSURE TO BEAM.
vi
QX-830 Compact Industrial Scanner User Manual
Page 7
Introduction
Warning and Caution Summary (cont.)
• Wavelength: 655 nm • Beam Divergence: 0.4mrad (typ.) • Pulse Duration: 40~186µs • Maximum Power: 1.75mW • Location of the QX-830’s laser aperture:
Laser Aperture AVOID EXPOSURE – Laser Radiation is emitted from this aperture. CAUTION: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. IMPORTANT: The QX-830 is intended for connection to a UL-listed direct plug-in power unit marked Class 2 and rated 5 VDC at 3.5 Watts, or greater if using electrical accessories. European models must use a similarly rated Class 1 or Class 2 power supply that is certified to comply with standard for safety EN 60950.
QX-830 Compact Industrial Scanner User Manual vii
Page 8
Warning and Caution Summary
Warning and Caution Summary (cont.) Warning Label Placement These labels are located on the QX-830 Compact Industrial Scanner. On Side
On Base viii
QX-830 Compact Industrial Scanner User Manual
Page 9
Introduction
Statement of Agency Compliance
The QX-830 has been tested for compliance with FCC (Federal Communications Commission) regulations and has been found to conform to all applicable FCC Rules and Regulations. To comply with FCC RF exposure compliance requirements, this device must not be co-located or operate in conjunction with any other antenna or transmitter. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
The QX-830 has been tested for compliance with CE (Conformité Européenne) standards and guidelines, and has been found to conform to applicable CE standards, specifically the following requirements: Heavy Industrial: EN 61000-6-2:2005 Radiated Emissions: EN 55022:2006 Class A 30-1000 MHz Conducted Emissions: EN 55022:2006 Class A .15-30 MHz The QX-830 has been tested by an independent electromagnetic compatibility laboratory in accordance with the applicable specifications and instructions.
QX-830 Compact Industrial Scanner User Manual ix
Page 10
Statement of RoHS Compliance
Statement of RoHS Compliance All Microscan readers with a ‘G’ suffix in the FIS number are RoHS-Compliant. All compliant readers were converted prior to March 1, 2007. All standard accessories in the Microscan Product Pricing Catalog are RoHS-Compliant except 20-500013-01 and 98-000039-02. These products meet all the requirements of “Directive 2002/95/EC” European Parliament and the Council of the European Union for RoHS compliance. In accordance with the latest requirements, our RoHS-Compliant products and packaging do not contain intentionally added Deca-BDE, Perfluorooctanes (PFOS) or Perfluorooctanic Acid (PFOA) compounds above the maximum trace levels. To view the document stating these requirements, please visit: http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=CELEX:32002L0095:EN:HTML and http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2006:372:0032:0034:EN:PDF
Please contact your sales manager for a complete list of Microscan’s RoHS-Compliant products. This declaration is based upon information obtained from sources which Microscan believes to be reliable, and from random sample testing; however, the information is provided without any representation of warranty, expressed or implied, regarding accuracy or correctness. Microscan does not specifically run any analysis on our raw materials or end product to measure for these substances. The information provided in this certification notice is correct to the best of Microscan’s knowledge at the date of publication. This notice is not to be considered a warranty or quality specification. Users are responsible for determining the applicability of any RoHS legislation or regulations based on their individual use of the product. In regards to “RoHS Directive 2011_65_EU” Microscan produces Monitoring and Control Instruments as well as Industrial Monitoring & Control Instruments as defined within the directive. Microscan has developed and is implementing a RoHS2 compliance plan with the intention of bringing all active products listed in our current marketing literature within full compliance as per the directive deadlines. Key milestones for the transition plan are as follows: • Complete internal product audit by July 2014. • Initial “Monitoring and Control Instruments” RoHS2 compliant products available by December 2014 • Initial “Industrial Monitoring & Control Instruments” RoHS2 compliant products available by July 2015 • All new products introduced in 2015 are expected to be WEEE & RoHS2 compliant. Microscan will mark the products with the ‘CE’ marking that complies with the RoHS2 process to acquire ‘CE’ certification per the example given: Example >> Machinery directive + EMC directive + RoHS2 = Declaration of Conformity.
x
QX-830 Compact Industrial Scanner User Manual