A two-page quick start guide for the Microscan QX-830 Compact Industrial Scanner. It lists the hardware and cordsets for standalone setups with or without the QX-1 Interface Device. It then walks through connecting to an RS-232 or Ethernet host, installing ESP software, connecting, testing read rate, and configuring the scanner.

Device
Compact industrial scanner p. 1
Host interfaces
RS-232 serial or Ethernet TCP/IP p. 1, 2
Connectors
Port A for the power supply; port B for the serial or Ethernet host cable p. 1
Power supply
QX Power Supply, 100-240VAC, +24VDC, M12 12-pin socket p. 1
Serial cordsets
M12 12-pin plug to DB9 socket, or M12 12-pin socket to DB9 socket, 1 m p. 1
Ethernet cordsets
M12 8-pin plug (Ultra-Lock or screw-on) to RJ45, 1 m p. 1
Common cordset
M12 12-pin socket to M12 12-pin plug, 1 m p. 1
Photo sensor
QX Photo Sensor, M12 4-pin plug, NPN, dark on, 2 m p. 1
Interface device
QX-1 Interface Device, optional, for standalone and daisy chain setups p. 1
Setup software
ESP, on the Microscan Tools Drive packaged with the scanner, or from the Download Center p. 1
ESP PC minimum
233 MHz Pentium PC, 128 MB RAM, 160 MB free disk, 800 x 600 256 color display p. 1
ESP operating systems
Windows 8, 7, Vista, or XP (32-bit or 64-bit), Internet Explorer 6.0 or higher p. 1
Default read mode
Continuous Read Mode p. 2
Read rate LEDs
LEDs on the side show the percentage of successful decodes per second p. 2

What this manual walks you through

  • Checking the hardware and cordsets needed p. 1
  • Connecting the scanner to an RS-232 host without the QX-1 p. 1
  • Connecting the scanner to an Ethernet host without the QX-1 p. 1
  • Positioning the scanner and a test symbol p. 1
  • Installing ESP and selecting the QX-830 model p. 1
  • Connecting ESP to the scanner over RS-232 or Ethernet p. 2
  • Testing the read rate p. 2
  • Changing and saving the scanner configuration in ESP p. 2

Good to know

  • Align Ultra-Lock connector pins and push straight in; twisting bends the pins. p. 1
  • One power supply powers no more than four scanners in a daisy chain. p. 1
  • Secure all connections before applying power, and power down before disconnecting any cable. p. 1
  • Configure Ethernet-enabled scanners off-line, then connect them to the network. p. 1
  • Keep decodable symbols out of the field of view while connecting. p. 2

Questions this manual answers

What software sets up the Microscan QX-830?

ESP, found on the Microscan Tools Drive packaged with the scanner; it can also be installed from the Download Center at www.microscan.com. p. 1

How many QX-830 scanners can share one power supply?

No more than four in a daisy chain; add a QX-1 and one power supply for every four more scanners. p. 1

Which QX-830 port takes power and which takes the host cable?

The power supply connects to A and the serial or Ethernet communication cable connects to B. p. 1

What PC does ESP need for the QX-830?

At least a 233 MHz Pentium PC with Windows 8, 7, Vista, or XP, 128 MB RAM, and 160 MB free disk space. p. 1

How do I test the QX-830 read rate?

Click Test in ESP's EZ Mode, watch the Symbol Information table or the Read Rate LEDs, then click Stop. p. 2

The file

Size and text

Pages2
PDF693 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Microscan QX-830 Quick Start Guide

The text of page 1, from the PDF itself

Quick Start Guide

Step 2, Connect the System

Step 1, Check Hardware

QX-830 Compact Industrial Scanner

Important: If you are connecting Ultra-Lock cordsets to the QX-830 and QX-1, align the pins first and then push the connector into place. Do not twist the connectors, as this will bend the pins.

1 1 532 6

Important: Do not attempt to power more than four scanners with a single power supply in a daisy chain configuration. Add a QX-1 and one power supply for every four additional scanner in the daisy chain.

764 or 78Standalone (with QX-1)

Standalone (without QX-1)

Hardware Required Caution: Be sure that all connections are secure BEFORE applying power. Always power down BEFORE disconnecting any cables. Item Description 1 QX-830 Compact Industrial Scanner 2 QX-1 Interface Device 3 QX Cordset, Common, M12 12-pin Socket to M12 12-pin Plug, 1 m 4 QX Cordset, Host, Serial, M12 12-pin Plug to DB9 Socket, 1 m 5 QX Cordset, Host, Serial, M12 12-pin Socket to DB9 Socket, 1 m 6 QX Power Supply, 100-240VAC, +24VDC, M12 12-pin Socket 7 QX Cordset, Host, Ethernet, M12 8-pin Plug (Ultra-Lock) to RJ45, 1 m or QX Cordset, Host, Ethernet, M12 8-pin Plug (Screw-On) to RJ45, 1 m 8 QX Photo Sensor, M12 4-pin Plug, NPN, Dark On, 2 m

P/N 83-110830-04 Rev A

Step 3, Position Scanner 1. Place a test symbol in a location with as little ambient light as possible. 2. Position the scanner at the focal distance used in your application. 3. Align the test symbol with the scanner’s field of view. 4. Tip the scanner relative to the test symbol to avoid glare from specular reflection.

Part Number FIS-0830-XXXXG 98-000103-02 61-000162-02 61-000152-02 61-000153-02 97-000012-01 61-000160-01 61-000160-02 99-000020-02

Note: The configuration instructions below are for simple, direct connections to an RS-232 or Ethernet host. The QX-1 can be added to RS-232 or Ethernet configurations in which greater flexibility and complexity are required. The first diagram in Step 1 shows a standalone configuration that includes the QX-1.

RS-232 Standalone (without QX-1) 1. Connect the Serial Communication Cable from “B” on the QX-830 to the host. 2. Connect the power supply to “A” on the QX-830. 3. Plug in the power supply.

Ethernet Standalone (without QX-1) Important: Configure Ethernet-enabled scanners off-line and then connect to network when ready for dynamic use. 1. Connect the Ethernet Communication Cable from “B” on the QX-830 to the host network. 2. Connect the power supply to “A” on the QX-830. 3. Plug in the power supply.

Note: Additional cordsets and accessories are available in the Product Pricing Catalog.

Step 4, Install ESP ESP Software can be found on the Microscan Tools Drive that is packaged with the QX-830. 1. Follow the prompts to install ESP from the Tools Drive. 2. Click on the ESP icon to run the program.

Step 5, Select Model When you start ESP, the model menu will appear:

Note: ESP can also be installed from the Download Center at www.microscan.com. Refer to the QX-830 Compact Industrial Scanner User Manual for detailed information about using ESP to configure the QX-830.

Minimum System Requirements

233 MHz Pentium PC Windows 8, 7, Vista, or XP operating system (32-bit or 64-bit) Internet Explorer 6.0 or higher 128 MB RAM or greater 160 MB free disk space 800 x 600 256 color display (1024 x 768 32-bit color recommended)

1. Click the button showing the QX-830. 2. Click OK. Note: You can also simply double-click the button showing your scanner to make your selection. 3. Click Yes when this dialog appears:

Note: If you need to select another model later, click the Switch Model button near the top of the screen or use Model > New Model in the menu toolbar. Copyright ©2015 Microscan Systems, Inc.

Page 2 of Microscan QX-830 Quick Start Guide

The text of page 2, from the PDF itself

Step 6, Connect

Step 6, Connect (cont.)

Step 6, Connect (cont.)

RS-232

Ethernet TCP/IP

Ethernet TCP/IP (cont.)

To connect using the Connection Wizard:

  • Click Connect on the menu toolbar, and then select Connection Wizard.
  • Select RS-232.
  • Configure RS-232 settings as required by the application, and click Connect.

To connect using the Connection Wizard:

  • Click Connect on the menu toolbar, and then select Connection Wizard.
  • Select Ethernet.
  • Configure Ethernet settings as required by the application, and click Connect.

When the QX-830 is connected, incoming symbol data can be displayed in the Terminal, as shown below.

  • When a connection is established, the green indicator in the status bar at the bottom right of the screen will be visible:
  • When a connection is established, the green indicator in the status bar at the bottom right of the screen will be visible:

Important: The scanner is in Continuous Read Mode by default. For best connection results, be sure that no decodable symbols are within the scanner’s field of view while attempting to connect.

Important: The scanner is in Continuous Read Mode by default. For best connection results, be sure that no decodable symbols are within the scanner’s field of view while attempting to connect.

Step 7, Test Read Rate Read Rate indicates the number or percentage of successful decodes per second achieved by the scanner. 1. Click the Test button in ESP’s EZ Mode to start the Read Rate test. Symbol data and read rate percentage information should appear in the Symbol Information table. The Read Rate LEDs on the side of the QX-830 will indicate the percentage of successful decodes per second. 2. Click Stop to end the Read Rate test. Note: Read Rate can also be tested using the Read Rate interface in Utilities.

Step 8, Configure and Save Click the App Mode button to make configuration changes to the scanner.

The following modes are accessible by clicking the buttons at the top of the screen:

Refer to the QX-830 Compact Industrial Scanner User Manual for information about how to test read rate using serial commands or the scanner’s EZ button.

Copyright ©2015 Microscan Systems, Inc.

Click the EZ Mode button to return to EZ Mode. Click the Autoconnect button to establish communications. Click the Send/Recv button to send or receive commands. Click the Switch Model button to open the model menu, or to return to the previous model. Click the Parameters button to show the tabbed tree control views. Click the Setup button to show the tabbed interface views. Click the Terminal button to display decoded symbol data and to send serial commands. Click the Utilities button to access Read Rate, Counters, Device Control, Differences from Default, Master Database, Digital Bar Code, and Firmware. For further details, see ESP Help in the Help dropdown menu.