Page 81

Symbologies

Aztec Read the following symbols to enable/disable Aztec settings: Aztec On

Aztec Off (Default)

Aztec by ESP

Sample Aztec Symbol

Note: Aztec is available only in Standard Mode.

Save Settings

MS-Q Imager User’s Manual

Default to USB

Default to PS/2

Clear All Data

Clear XML Rules

5-3

Page 82

Codabar

Codabar Read the following symbols to enable/disable Codabar settings: Codabar On (Default)

Codabar Off

Codabar by ESP

ESP allows you enable a checksum, or to enable a check sum and remove it from the decode result.

Sample Codabar Symbol

Note: Codabar is available only in Standard Mode.

Save Settings

5-4

Default to USB

Default to PS/2

Clear All Data

Clear XML Rules

MS-Q Imager User’s Manual

Page 83

Symbologies

Codablock F Read the following symbols to enable/disable Codablock F settings: Codablock F On

Codablock F Off (Default)

Codablock by ESP Note: ESP offers Codablock A in addition to Codablock F.

Important: When Codablock F and Code 128 are both enabled, there is some risks of mistakenly decoding a damaged Codablock F symbol as a Code 128 symbol. Therefore, whenever possible, Code 128 should be disabled when Codablock F is enabled.

Sample Codablock F Symbol

Note: Codablock F and Codablock A are available only in Standard Mode.

Save Settings

MS-Q Imager User’s Manual

Default to USB

Default to PS/2

Clear All Data

Clear XML Rules

5-5

Page 84

Code 11

Code 11 Read the following symbols to enable/disable Code 11 settings: Code 11 Enabled with 2 Checksum Digits

Code 11 Disabled (Default)

Enabled with 1 Checksum Digit

Enabled with 2 Checksum Digits and Stripped from Result

Enabled with 1 Checksum Digit and Stripped from Result

Code 11 by ESP Note: “No Report” in ESP has the same meaning as “Stripped from Result”.

Sample Code 11 Symbol

Note: Code 11 is available only in Standard Mode.

5-6

MS-Q Imager User’s Manual

Page 85

Symbologies

Code 39 Read the following symbols to enable/disable Code 39 settings: Code 39 On (Default)

Code 39 Off

Enable Checksum

Disable Checksum (Default)

Enable Checksum and Strip from Result

Code 39 Extended Full ASCII On

Code 39 Extended Full ASCII Off (Default)

Code 39 Narrow Margins On

Code 39 Narrow Margins Off (Default)

Code 39 Trioptic On

Code 39 Trioptic Off

Save Settings

MS-Q Imager User’s Manual

Default to USB

Default to PS/2

Clear All Data

Clear XML Rules

5-7

Page 86

Code 39

Code 39 by ESP

Sample Code 39 Symbol

Sample Code 39 Trioptic Symbol

Note: Code 39 is available only in Standard Mode.

Save Settings

5-8

Default to USB

Default to PS/2

Clear All Data

Clear XML Rules

MS-Q Imager User’s Manual

Page 87

Symbologies

Code 93 Read the following symbols to enable/disable Code 93 settings: Code 93 On (Default)

Code 93 Off

Code 93 by ESP

Sample Code 93 Symbol

Note: Code 93 is available only in Standard Mode.

Save Settings

MS-Q Imager User’s Manual

Default to USB

Default to PS/2

Clear All Data

Clear XML Rules

5-9

Page 88

Code 128

Code 128 Read the following symbols to enable/disable Code 128 settings: Code 128 On (Default)

Code 128 Off

Code 128 Narrow Margins On

Code 128 Narrow Margins Off (Default)

Code 128 by ESP

Sample Code 128 Symbol

Note: Code 128 is available only in Standard Mode.

Save Settings

5-10

Default to USB

Default to PS/2

Clear All Data

Clear XML Rules

MS-Q Imager User’s Manual

Page 89

Symbologies

Composite To read Composite symbols: 1. Enable the corresponding linear component. 2. Read the Composite On symbol below. Important: Both the linear symbology and Composite must be enabled before the imager can fully decode a Composite symbol. Composite On

Composite Off (Default)

Composite by ESP Composite Linkage Control

When Composite Linkage Control is set to Required, symbol data will only be output if both the 2D and 1D components of the symbol are decoded. When not required, symbol data will be output even when only one of the components is decoded.

Maximum Decodes per Read

Maximum Decodes per Read represents the maximum number of candidate symbols in the field of view that can be decoded during a read cycle. Note that decode speed will decrease as the Maximum Decodes per Read value is increased.

Sample Composite Symbol

Note: Composite is available only in Standard Mode.

MS-Q Imager User’s Manual

5-11

Page 90

Data Matrix

Data Matrix Read the following symbols to enable/disable Data Matrix settings: Data Matrix Rectangle On

Data Matrix Rectangle Off

Data Matrix Inverse On

Data Matrix Inverse Off

Note: Data Matrix is available in both Quadrus Only and Standard modes. Data Matrix ECC 0-140 On

Data Matrix ECC 0-140 Off (Default)

Note: Data Matrix ECC 0-140 is available for MS-Q Quadrus models only. Enable Data Matrix Improvements (For Low Contrast and Binarized Symbols)

Disable Data Matrix Improvements

Sample Data Matrix Symbol

Sample Rectangular Data Matrix Symbol

Data Matrix by ESP

Save Settings

5-12

Default to USB

Default to PS/2

Clear All Data

Clear XML Rules

MS-Q Imager User’s Manual