Page 111
I/O Parameters
MS-Q Operational Feedback Memory LED (LEFT indicator) Successfully Powered-On Flashes GREEN Successfully Enumerated None with Host via USB Cable Attempting to Decode None Successful Decode and None Cabled Data Transfer Successful Decode and Memory Status Data Storage Batch Memory Full Solid RED Configuration Symbol None Successfully Processed Configuration Symbol Successfully Decoded but None Not Processed Attempting to Connect to Flashes BLUE Bluetooth Bluetooth Connection None Failed Bluetooth Connection Flashes BLUE every 15 Successful seconds Sending Bluetooth Data Flashes Memory Status Imager Activity
Battery LEDa (RIGHT indicator) Flashes GREEN
1 beep
Solid GREEN
1 beep
Battery Status
None
Solid GREEN
1 beep
None
1 beep
None None
3 beeps 1 beep, pause, 1 beep
None
6 beeps
Solid GREEN
None
None
4 beeps
Flashes Battery Status every 15 seconds None
None
Sound
None a. When power is supplied via cable, the LED will remain green whenever the imager is active.
Left / Right Top LEDs When not active, the MS-Q will flash battery or power status every 15 seconds. The colors will vary depending on the message the imager is sending. • GREEN = 50-100% battery capacity OR 100% of memory available. • AMBER = 20-50% battery capacity OR 20-99% of memory available. • RED = 0-20% battery capacity or no memory available. • BLUE = Bluetooth Mode The MS-Q also emits beeps and/or vibrates to indicate specific information to the user. Refer to the table above to better understand MS-Q feedback.
MS-Q Imager User’s Manual
Left LED
Right LED
6-5
Page 112
Trigger and Button Programming
Trigger and Button Programming Trigger and button functionality can be configured to read just near field, just far field, or both fields using the symbols shown below.
Handle Trigger Programming Both Fields (Default)
Near Field Only
Far Field Only
Handle Trigger Take Picture
Left Button Programming Both Fields (Default)
Near Field Only
Far Field Only
Left Button Take Picture
Disable Left Button
Enable Left Button Mode Switching (Quadrus Only / Standard)
6-6
MS-Q Imager User’s Manual
Page 113
I/O Parameters
Right Button Programming Both Fields (Default)
Near Field Only
Far Field Only
Right Button Take Picture
Disable Right Button
See Trigger Optimization on page 7-7 for more trigger/button programming options.
Button/Trigger Confirmation Time The Button/Trigger Confirmation Time is the amount of time that a button, trigger, or combination of the trigger and/or buttons, must be held down before the imager recognizes that a triggering event has occurred.
Save Settings
MS-Q Imager User’s Manual
Default to USB
Default to PS/2
Clear All Data
Clear XML Rules
6-7
Page 114
Beep and Vibrate Settings
Beep and Vibrate Settings Read the following symbols to configure beep and vibrate settings.
Beep / Vibrate
Vibrate Off / Beep On (Default)
Vibrate On / Beep On
Vibrate On / Beep Off
Beep Off
Beep Quiet
Beep Volume
Beep Loud (Default)
Beep and Vibrate Settings by ESP
Note: Duration is the length of the beep in milliseconds with a configurable range of 0.000 to 2147483.750. Separation is the spacing in milliseconds between beeps, also with a configurable range of 0.000 to 2147483.750.
Save Settings
6-8
Default to USB
Default to PS/2
Clear All Data
Clear XML Rules
MS-Q Imager User’s Manual
Page 115
I/O Parameters
Automatic Gain Control (AGC) AGC is a system that controls gain in order to maintain high performance over a range of input levels. Gain is essentially the ratio of output to input. Gain settings affect how the MS-Q decodes symbols and captures images.
AGC Selection
The MS-Q has two different types of gain control. Decoder AGC, the default setting, is optimized for decoding 1D and 2D symbols. Imager AGC is optimized for capturing images.
AGC Frame Adjust Count AGC Frame Adjust Count sets the number of image frames captured and discarded before the main image capture. This feature gives the gain control time to adjust.
Minimum Exposure Minimum Exposure is a percentage value that represents the minimum exposure allowed for image captures.
Maximum Exposure Maximum Exposure is a percentage value that represents the maximum exposure allowed for image captures.
MS-Q Imager User’s Manual
6-9
Page 116
Automatic Gain Control (AGC)
Minimum Gain Minimum Gain is a percentage value that represents the minimum gain adjustment allowed for decoder or imager AGC.
Maximum Gain Maximum Gain is a percentage value that represents the maximum gain adjustment allowed for decoder or imager AGC.
Gain Break Point Gain Break Point is a percentage value that represents the point at which the imager stops automatic gain adjustment.
6-10
MS-Q Imager User’s Manual
Page 117
I/O Parameters
LightRay Optics For Direct Part Mark applications or other situations that involve hard-to-read symbols, the MS-Q can be paired with an accessory called LightRay Optics. This accessory is easy to set up and easy to use. LightRay Optics comes in two series: the 100 and 200 series. Important: LightRay Optics can only be used with the original (H1) MS-Q handle.
LightRay Accessory Options Item LightRay 100 High Resolution LightRay 110 Standard Resolution Item LightRay 205 High Resolution LightRay 215 Standard Resolution
Part Number FIS-0001-0031G FIS-0001-0032G Part Number FIS-0001-0033G FIS-0001-0034G
MS-Q + LightRay Kits LightRay 100 Series, Rev 5 Hardware (or Earlier) MS-Q Quadrus, High Resolution, USB (PS/2, RS-232), LightRay 100 MS-Q Quadrus, High Resolution, Batch/Battery, LightRay 100 MS-Q Quadrus, High Resolution, Bluetooth, LightRay 100 MS-Q Quadrus, Standard Resolution, USB (PS/2, RS-232), LightRay 110 MS-Q Quadrus, Standard Resolution, Batch/Battery, LightRay 110 MS-Q Quadrus, Standard Resolution, Bluetooth, LightRay 110 LightRay 200 Series, Rev 5 Hardware (or Earlier) MS-Q Quadrus, High Resolution, USB (PS/2, RS-232), LightRay 205 MS-Q Quadrus, High Resolution, Batch/Battery, LightRay 205 MS-Q Quadrus, High Resolution, Bluetooth, LightRay 205 MS-Q Quadrus, Standard Resolution, USB (PS/2, RS-232), LightRay 215 MS-Q Quadrus, Standard Resolution, Batch/Battery, LightRay 215 MS-Q Quadrus, Standard Resolution, Bluetooth, LightRay 215 LightRay 100 Series, Rev 6 Hardware MS-Q Quadrus, High Resolution, USB (PS/2, RS-232), LightRay 100 MS-Q Quadrus, High Resolution, Bluetooth, LightRay 100 MS-Q Quadrus, Standard Resolution, USB (PS/2, RS-232), LightRay 110 MS-Q Quadrus, Standard Resolution, Batch/Battery, LightRay 110 LightRay 200 Series, Rev 6 Hardware MS-Q Quadrus, High Resolution, USB (PS/2, RS-232), LightRay 205 MS-Q Quadrus, High Resolution, Batch/Battery, LightRay 205 MS-Q Quadrus, High Resolution, Bluetooth, LightRay 205
MS-Q Imager User’s Manual
Part Number FIS-6100-1011G FIS-6100-1012G FIS-6100-1013G FIS-6100-1014G FIS-6100-1015G FIS-6100-1016G Part Number FIS-6100-2011G FIS-6100-2012G FIS-6100-2013G FIS-6100-2014G FIS-6100-2015G FIS-6100-2016G Part Number FIS-6100-1021G FIS-6100-1022G FIS-6100-1023G FIS-6100-1024G Part Number FIS-6100-2021G FIS-6100-2022G FIS-6100-2023G
6-11
Page 118
LightRay Optics
Setup Choose Field of View Near Field High Resolution (100)
Far Field Standard Resolution (110)
Near Field High Resolution (205)
Far Field Standard Resolution (215)
Laser On, LEDs On, 100% (100, 110)
Laser Off, LEDs On, 100% (100, 110)
Laser On, Visible LEDs Off, IR LEDs On, 100% (205, 215)
Laser Off, Visible Off, IR On, 100% (205, 215)
Set Up Illumination
Assembly (100 Series) • Place the 100 Series LightRay Optic attachment over the face of the MS-Q Imager.
• The plastic body of the LightRay Optics device should be pressed firmly against the face of the imager, allowing minimum slippage. • Be sure that the device and the imager’s face are aligned as precisely as possible.
Assembly (200 Series) • Place the 200 Series LightRay Optics attachment over the face of the MS-Q Imager. • The plastic body of the LightRay Optic device should be pressed firmly against the face of the imager, allowing minimum slippage. • But sure that the device and the imager’s face are aligned as precisely as possible.
6-12
MS-Q Imager User’s Manual
Page 119
I/O Parameters
Reading Symbols (100 Series) • For best results, begin triggering before the LightRay Optic has come in contact with the surface or substrate. • Center the symbol in the LightRay Optic guide’s cutout.
Guide
Reading Symbols (200 Series) • For best results, begin triggering before the LightRay Optic has come in contact with the surface or substrate. • Position the symbol equidistant from both of the 200 Series LightRay Optic’s guides.
Guides
Symbol
MS-Q Imager User’s Manual
6-13
Page 120
LightRay Optics
LightRay Optics by ESP The MS-Q Imager can also be configured and optimized for LightRay operation using ESP. Click on the series you are using. You can either use the radio buttons (“100 Series” and “200 Series”) or click directly on the pictures. The image of the selected model will glow, as shown in the example below.
Choose the field of view and resolution that match your LightRay Optics model.
Only available for Rev 5 hardware or earlier.
(200 Series selected)
Configure the handle trigger or left and right buttons with VGA Fast Read (if Rev 5 hardware or earlier) and Laser Target options.
Enable or disable UII functionality. (See UII Mode Settings by ESP on page 10-5.)
Send LightRay settings to the imager, or Send and Save all settings.
6-14
MS-Q Imager User’s Manual